Literature DB >> 31039055

Mid-term radiological results of a cementless short humeral component in anatomical and reverse shoulder arthroplasty.

W R Aibinder1, D W Bartels1, J W Sperling1, J Sanchez-Sotelo1.   

Abstract

AIMS: Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). PATIENTS AND METHODS: A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).
RESULTS: Greater tuberosity stress shielding was noted in 14 shoulders (two TSA and 12 RSA) and was graded as mild in nine, moderate in two, and severe in three. Medial calcar resorption was noted in 23 shoulders (seven TSA and 16 RSA), and was graded as mild in 21 and moderate in two. No humeral components were revised for loosening or considered to be loose radiologically. Nine shoulders underwent reoperation for infection (n = 3), fracture of the humeral tray (n = 2), aseptic glenoid loosening (n = 1), and instability (n = 3). No periprosthetic fractures occurred.
CONCLUSION: Implantation of this particular short cementless humeral component at the time of TSA or RSA was associated with a low rate of adverse radiological findings on the humeral side at mid-term follow-up. Our data do not raise any concerns regarding the use of a short stem in TSA or RSA. Cite this article: Bone Joint J 2019;101-B:610-614.

Entities:  

Keywords:  Short stem; Shoulder arthroplasty; Stress shielding

Mesh:

Year:  2019        PMID: 31039055     DOI: 10.1302/0301-620X.101B5.BJJ-2018-1374.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  6 in total

1.  Rigour will be important post-COVID-19.

Authors:  Fares S Haddad
Journal:  Bone Joint J       Date:  2020-09       Impact factor: 5.082

Review 2.  Innovations in Shoulder Arthroplasty.

Authors:  Nels Leafblad; Elise Asghar; Robert Z Tashjian
Journal:  J Clin Med       Date:  2022-05-16       Impact factor: 4.964

3.  Using standard-length compactors to implant short humeral stems in total shoulder arthroplasty: A cadaver study of humeral stem alignment.

Authors:  Stanislas Gunst; Ana Nigues; Jérôme Vogels; Elvire Servien; Sébastien Lustig; Laurent Nove-Josserand; Philippe Collotte
Journal:  PLoS One       Date:  2022-05-05       Impact factor: 3.240

4.  Clinical results and survivorship of the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis.

Authors:  Timothy James Karssiens; James Ritchie Gill; Karadi Hari Sunil Kumar; Søren Upton Sjolin
Journal:  Bone Jt Open       Date:  2021-01-22

5.  Measuring Patient Value after Total Shoulder Arthroplasty.

Authors:  Alexandre Lädermann; Rodolphe Eurin; Axelle Alibert; Mehdi Bensouda; Hugo Bothorel
Journal:  J Clin Med       Date:  2021-12-04       Impact factor: 4.241

6.  Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications).

Authors:  Francesco Ascione; Alfredo Schiavone Panni; Adriano Braile; Katia Corona; Giuseppe Toro; Nicola Capuano; Alfonso M Romano
Journal:  J Orthop Traumatol       Date:  2021-07-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.