Literature DB >> 31038246

Characterization of MRI techniques to assess neonatal brain oxygenation and blood flow.

Peiying Liu1, Charlamaine Parkinson2, Dengrong Jiang1,3, Minhui Ouyang4, Jill B De Vis1, Frances J Northington2, Aylin Tekes1, Hao Huang4, Thierry A G M Huisman1, W Christopher Golden2.   

Abstract

There is increasing interest in applying physiological MRI in neonates, based on the premise that physiological parameters may provide an early biomarker of neonatal brain health and injury. Two commonly used techniques are oxygen extraction fraction (OEF) measurement using T2 -relaxation-under-spin-tagging (TRUST) MRI and cerebral blood flow measurement using phase-contrast (PC) quantitative flow MRI, which collectively provide an assessment of the brain's oxygen consumption. However, prior research has only demonstrated proof of principle of these methods in neonates, without characterization or benchmarking of the techniques. This is because available time is limited in neonatal subjects, especially when scans are performed as add-ons to clinical scans (typically less than 5 min). The work presented aims to examine the TRUST and PC MRI sequences systematically in normal neonates, through research-dedicated scan sessions. A series of characterization and optimization studies were conducted in a total of 26 radiographically normal neonates on 3 T systems. Our results show that TRUST MRI at the superior sagittal sinus (SSS) provides an OEF measurement equivalent to that at the internal jugular vein (r = 0.80, n = 10), yet with shorter scan time. Lower resolution provided better precision in the TRUST measurement (p = 0.001, n = 9). Therefore, the preferred OEF measurement is to apply TRUST MRI at the SSS using a spatial resolution of 2.5 mm. For PC MRI, our results showed that non-gated PC MRI yielded blood flow measurements comparable to those from the more time-consuming gated approach in neonates (r = 0.89, n = 7). It was also found that blood flow could be overestimated by 18% when imaging resolution is larger than 0.3 mm (n = 7). Therefore, non-gated PC MRI with a spatial resolution of 0.3 mm is recommended for neonatal applications. In conclusion, this study verifies consistency of neonatal brain oxygenation and flow measurements across acquisition schemes and points to optimal strategies in parameter selection when using these sequences.
© 2019 John Wiley & Sons, Ltd.

Entities:  

Keywords:  TRUST MRI; cerebral blood flow; cerebral metabolic rate of oxygen; neonates; oxygen extraction fraction; phase-contrast MRI

Mesh:

Substances:

Year:  2019        PMID: 31038246      PMCID: PMC6581605          DOI: 10.1002/nbm.4103

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  33 in total

1.  THE EFFECTS OF ALTERED ARTERIAL TENSIONS OF CARBON DIOXIDE AND OXYGEN ON CEREBRAL BLOOD FLOW AND CEREBRAL OXYGEN CONSUMPTION OF NORMAL YOUNG MEN.

Authors:  S S Kety; C F Schmidt
Journal:  J Clin Invest       Date:  1948-07       Impact factor: 14.808

2.  Cerebral oxygen metabolism in neonates with congenital heart disease quantified by MRI and optics.

Authors:  Varsha Jain; Erin M Buckley; Daniel J Licht; Jennifer M Lynch; Peter J Schwab; Maryam Y Naim; Natasha A Lavin; Susan C Nicolson; Lisa M Montenegro; Arjun G Yodh; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2013-12-11       Impact factor: 6.200

3.  Phase-contrast magnetic resonance angiography measurements of global cerebral blood flow in the neonate.

Authors:  Manon J N L Benders; Jeroen Hendrikse; Linda S De Vries; Frank Van Bel; Floris Groenendaal
Journal:  Pediatr Res       Date:  2011-06       Impact factor: 3.756

4.  Size-adaptable 13-channel receive array for brain MRI in human neonates at 3 T.

Authors:  Nibardo Lopez Rios; Alexandru Foias; Gregory Lodygensky; Mathieu Dehaes; Julien Cohen-Adad
Journal:  NMR Biomed       Date:  2018-06-21       Impact factor: 4.044

5.  Assessment of cerebral blood flow in neonates and infants: A phase-contrast MRI study.

Authors:  Peiying Liu; Ying Qi; Zixuan Lin; Qiyong Guo; Xiaoming Wang; Hanzhang Lu
Journal:  Neuroimage       Date:  2018-03-10       Impact factor: 6.556

6.  On improving the speed and reliability of T2-relaxation-under-spin-tagging (TRUST) MRI.

Authors:  Feng Xu; Jinsoo Uh; Peiying Liu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

7.  Test-retest reproducibility of a rapid method to measure brain oxygen metabolism.

Authors:  Peiying Liu; Feng Xu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2012-04-19       Impact factor: 4.668

8.  Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI.

Authors:  Hanzhang Lu; Yulin Ge
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

9.  Dependence of blood T(2) on oxygenation at 7 T: in vitro calibration and in vivo application.

Authors:  Lisa C Krishnamurthy; Peiying Liu; Feng Xu; Jinsoo Uh; Ivan Dimitrov; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2013-07-10       Impact factor: 4.668

10.  Hemodynamic and Metabolic Assessment of Neonates With Punctate White Matter Lesions Using Phase-Contrast MRI and T2-Relaxation-Under-Spin-Tagging (TRUST) MRI.

Authors:  Ying Qi; Peiying Liu; Zixuan Lin; Hanzhang Lu; Xiaoming Wang
Journal:  Front Physiol       Date:  2018-03-19       Impact factor: 4.566

View more
  1 in total

Review 1.  Cerebral oxygen extraction fraction MRI: Techniques and applications.

Authors:  Dengrong Jiang; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2022-05-05       Impact factor: 3.737

  1 in total