Literature DB >> 31034899

Dose reduction in perfusion CT in stroke patients by lowering scan frequency does not affect automatically calculated infarct core volumes.

Grzegorz Marek Karwacki1, Stephan Vögele2, Kristine Ann Blackham2.   

Abstract

BACKGROUND AND
PURPOSE: CT Perfusion technique (CTP) is a quantitative, easily performed, accepted and reliable method for detection of ischemic brain changes. Based on calculated parameters, the size of ischemic penumbra and irreversibly damaged infarct core can be determined which helps guide treatment decisions. However, due to the dynamic nature of the CTP study, it is dose intensive. This study determines the consequences of retrospectively reducing the number of scans in the dynamic acquisition by half on the volume of the automatically calculated infarct core (non-viable tissue) and penumbra (tissue at risk) volumes. Our hypothesis was that equivalent volumetric information could be obtained at a substantial dose savings.
MATERIALS AND METHODS: Fifty one consecutive patients with occlusion of M1 and/or M2 segment of the middle cerebral artery and ischemic stroke proven by follow-up MRI were included. CTP scans were first analyzed in a standard fashion and automatically generated volumes measured in milliliters were recorded in a database. A second analysis was conducted after removing every second data acquisition from the sequential CTP scans. Automatic volume measurements were repeated, recorded and compared to the initial values obtained using the full dataset.
RESULTS: The two CTP protocols were statistically equivalent pertaining to automatic infarct core volume calculation but a case-by-case analysis revealed substantial overestimation in some cases.
CONCLUSION: Reduction of radiation exposure in CTP without objective loss of accuracy of automatically calculated infarct core volume is feasible but might lead to clinically relevant infarct core overestimation in individual cases.
Copyright © 2019 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  CT Perfusion; Infarct; Penumbra; Stroke; Volume

Mesh:

Year:  2019        PMID: 31034899     DOI: 10.1016/j.neurad.2019.04.004

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  1 in total

1.  A Novel Singular Value Decomposition-Based Denoising Method in 4-Dimensional Computed Tomography of the Brain in Stroke Patients with Statistical Evaluation.

Authors:  Wonseok Yang; Jun-Yong Hong; Jeong-Youn Kim; Seung-Ho Paik; Seung Hyun Lee; Ji-Su Park; Gihyoun Lee; Beop Min Kim; Young-Jin Jung
Journal:  Sensors (Basel)       Date:  2020-05-28       Impact factor: 3.576

  1 in total