Literature DB >> 31034462

Reliability and Concurrent Validity of Seven Commercially Available Devices for the Assessment of Movement Velocity at Different Intensities During the Bench Press.

Alejandro Pérez-Castilla1, Antonio Piepoli2, Gabriel Delgado-García1, Gabriel Garrido-Blanca2, Amador García-Ramos1,3.   

Abstract

Pérez-Castilla, A, Piepoli, A, Delgado-García, G, Garrido-Blanca, G, and García-Ramos, A. Reliability and concurrent validity of seven commercially available devices for the assessment of movement velocity at different intensities during the bench press. J Strength Cond Res 33(5): 1258-1265, 2019-The aim of this study was to compare the reliability and validity of 7 commercially available devices to measure movement velocity during the bench press exercise. Fourteen men completed 2 testing sessions. One-repetition maximum (1RM) in the bench press exercise was determined in the first session. The second testing session consisted of performing 3 repetitions against 5 loads (45, 55, 65, 75, and 85% of 1RM). The mean velocity was simultaneously measured using an optical motion sensing system (Trio-OptiTrack; "gold-standard") and 7 commercially available devices: 1 linear velocity transducer (T-Force), 2 linear position transducers (Chronojump and Speed4Lift), 1 camera-based optoelectronic system (Velowin), 1 smartphone application (PowerLift), and 2 inertial measurement units (IMUs) (PUSH band and Beast sensor). The devices were ranked from the most to the least reliable as follows: (a) Speed4Lift (coefficient of variation [CV] = 2.61%); (b) Velowin (CV = 3.99%), PowerLift (3.97%), Trio-OptiTrack (CV = 4.04%), T-Force (CV = 4.35%), and Chronojump (CV = 4.53%); (c) PUSH band (CV = 9.34%); and (d) Beast sensor (CV = 35.0%). A practically perfect association between the Trio-OptiTrack system and the different devices was observed (Pearson's product-moment correlation coefficient (r) range = 0.947-0.995; p < 0.001) with the only exception of the Beast sensor (r = 0.765; p < 0.001). These results suggest that linear velocity/position transducers, camera-based optoelectronic systems, and the smartphone application could be used to obtain accurate velocity measurements for restricted linear movements, whereas the IMUs used in this study were less reliable and valid.

Entities:  

Mesh:

Year:  2019        PMID: 31034462     DOI: 10.1519/JSC.0000000000003118

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  34 in total

1.  The Validity and Reliability of Commercially Available Resistance Training Monitoring Devices: A Systematic Review.

Authors:  Jonathon Weakley; Matthew Morrison; Amador García-Ramos; Rich Johnston; Lachlan James; Michael H Cole
Journal:  Sports Med       Date:  2021-01-21       Impact factor: 11.136

2.  Effects of Percutaneous Electrical Nerve Stimulation on Countermovement Jump and Squat Performance Speed in Male Soccer Players: A Pilot Randomized Clinical Trial.

Authors:  Gracia María Gallego-Sendarrubias; José Luis Arias-Buría; Edurne Úbeda-D'Ocasar; Juan Pablo Hervás-Pérez; Manuel Antonio Rubio-Palomino; César Fernández-de-Las-Peñas; Juan Antonio Valera-Calero
Journal:  J Clin Med       Date:  2021-02-10       Impact factor: 4.241

Review 3.  Training for Muscular Strength: Methods for Monitoring and Adjusting Training Intensity.

Authors:  Timothy J Suchomel; Sophia Nimphius; Christopher R Bellon; W Guy Hornsby; Michael H Stone
Journal:  Sports Med       Date:  2021-06-08       Impact factor: 11.928

4.  Reliability of technologies to measure the barbell velocity: Implications for monitoring resistance training.

Authors:  Alejandro Martínez-Cava; Alejandro Hernández-Belmonte; Javier Courel-Ibáñez; Ricardo Morán-Navarro; Juan José González-Badillo; Jesús G Pallarés
Journal:  PLoS One       Date:  2020-06-10       Impact factor: 3.240

5.  The Reliability and Validity of Current Technologies for Measuring Barbell Velocity in the Free-Weight Back Squat and Power Clean.

Authors:  Steve W Thompson; David Rogerson; Harry F Dorrell; Alan Ruddock; Andrew Barnes
Journal:  Sports (Basel)       Date:  2020-06-30

6.  Acute Effects of Beetroot Juice Supplements on Resistance Training: A Randomized Double-Blind Crossover.

Authors:  Antonio Ranchal-Sanchez; Victor Manuel Diaz-Bernier; Candelaria Alonso De La Florida-Villagran; Francisco Jesus Llorente-Cantarero; Julian Campos-Perez; Jose Manuel Jurado-Castro
Journal:  Nutrients       Date:  2020-06-28       Impact factor: 5.717

7.  Validity of the iLOAD® app for resistance training monitoring.

Authors:  Evandro Claudino de Sá; André Ricarte Medeiros; André Santana Ferreira; Amador García Ramos; Danica Janicijevic; Daniel Boullosa
Journal:  PeerJ       Date:  2019-08-07       Impact factor: 2.984

8.  Physiological Predictors of Competition Performance in CrossFit Athletes.

Authors:  Rafael Martínez-Gómez; Pedro L Valenzuela; Lidia B Alejo; Jaime Gil-Cabrera; Almudena Montalvo-Pérez; Eduardo Talavera; Alejandro Lucia; Susana Moral-González; David Barranco-Gil
Journal:  Int J Environ Res Public Health       Date:  2020-05-24       Impact factor: 3.390

9.  Validity and Reliability of Kinematics Measured with PUSH Band vs. Linear Encoder in Bench Press and Push-Ups.

Authors:  Roland van den Tillaar; Nick Ball
Journal:  Sports (Basel)       Date:  2019-09-10

10.  A Cluster Set Protocol in the Half Squat Exercise Reduces Mechanical Fatigue and Lactate Concentrations in Comparison with A Traditional Set Configuration.

Authors:  D Varela-Olalla; A Romero-Caballero; J Del Campo-Vecino; C Balsalobre-Fernández
Journal:  Sports (Basel)       Date:  2020-04-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.