| Literature DB >> 31033451 |
Thomas Boillat1, Peter Grantcharov2, Homero Rivas3.
Abstract
BACKGROUND: Studies have demonstrated that surgical safety checklists (SSCs) can significantly reduce surgical complications and mortality rates. Such lists rely on traditional posters or paper, and their contents are generic regarding the type of surgery being performed. SSC completion rates and uniformity of content have been reported as modest and widely variable.Entities:
Keywords: smart glasses; surgery; surgical safety checklists; time-out event; usability
Year: 2019 PMID: 31033451 PMCID: PMC6658283 DOI: 10.2196/13447
Source DB: PubMed Journal: JMIR Mhealth Uhealth ISSN: 2291-5222 Impact factor: 4.773
Existing research on the uses of smart glasses in health care.
| Reference | Study design | Purpose of smart glasses use | Remote diagnosis and assistance | Video documentation | Photo documentation | Access patient information | (Self)-guidance |
| [ | Pilot | Evaluate capacity of smart glasses to enhance communication, document cases, and access patient information | X | X | X | ||
| [ | Feasibility | Evaluate capacity of smart glasses to enhance communication and document cases | X | X | X | ||
| [ | Pilot | Use of head-mounted display on smart glasses to display vital sign parameters | X | ||||
| [ | Pilot | List of smart glasses opportunities (eg, access to online medical encyclopedia, patient information, documentation, remote assistance) | X | X | X | ||
| [ | Case | Document cases and analyze pictures | X | ||||
| [ | Pilot | Record first-person point-of-view video and photos and use as search engine | X | X | X | ||
| [ | Pilot | Live-stream video during surgery and facilitate remote telementoring between 2 surgeons, allowing real-time guidance of the operating surgeon | X | X | |||
| [ | Feasibility | Assess the safety of using Google Glass by assessing the video quality of a telementoring session | X | ||||
| [ | Pilot | Facilitate real-time observation and proctoring by mentoring surgeon experts in remote locations around the world | X | ||||
| [ | Pilot | Enhance neuronavigation by projecting images directly on the Google Glass screen instead of traditional screens | X | Xa | |||
| [ | Pilot | Evaluate the use of Google Glass to document airway assessment and tracheal intubation | X | ||||
| [ | Randomized controlled | Evaluate whether Google Glass can be used to perform an ultrasound-guided procedure | X |
aSelf-guidance was the secondary and not primary goal in surgery.
Figure 1Data collection throughout the research process. SSC: surgical safety checklist.
Figure 2Checklist items displayed in the smart glasses app versus wall poster.
Checklist completion rates by recall medium.
| Checklist item | Recall medium | |||
| Memory (n=20) | Poster (n=12) | Memory + poster (n=8) | Smart glasses (phase 1; n=15) | |
| Correct patient | 20 (100) | 11 (83) | 8 (100) | 15 (100) |
| Correct procedure | 17 (85) | 11 (92) | 8 (100) | 15 (100) |
| Correct position | 17 (85) | 12 (100) | 4 (50) | 15 (100) |
| Correct operative site/side | 1 (5) | 6 (50) | 0 (0) | 15 (100) |
| Consent completed, accurate, and signed | 16 (80) | 12 (100) | 8 (100) | 15 (100) |
| Surgical site marked by surgeon and visible after preparation/after drape | 3 (15) | 9 (75) | 5 (62) | 15 (100) |
| Confirmation of allergies | 19 (100) | 12 (100) | 8 (100) | 15 (100) |
| Images/implants available | 12 (60) | 9 (75) | 3 (38) | 15 (100) |
| Prophylactic antibiotic given | 20 (100) | 12 (100) | 8 (100) | 15 (100) |
| DVTa prophylaxis | 18 (90) | 10 (83) | 8 (100) | 15 (100) |
| Procedure duration | 16 (80) | 11 (92) | 6 (75) | 15 (100) |
| Any patient-specific concerns, are we all in agreement? | 15 (75) | 12 (100) | 6 (75) | 15 (100) |
| Is EBLa>500 cc or is there possibility of major blood loss? | 18 (80) | 10 (83) | 8 (100) | 15 (100) |
| Introduction by roles | 11 (55) | 1 (8) | 6 (75) | 11 (73) |
| Average | 14.4 (72) | 10 (83) | 6.2 (77) | 14.7 (98) |
| Standard deviation | 3.2 (16) | 1 (8) | 0.8 (10) | 0.45 (3) |
aDVT: deep vein thrombosis.
aEBL: estimated blood loss.
Figure 3Completion rates across all mediums.
| Memory | Memory + poster | Poster | Smart glasses (phase 1) | Smart glasses (phase 2) | |
| Average duration (seconds) | 54.8 | 58.5 | 60.8 | 85.7 | 47.7 |
| Standard deviation (seconds) | 10.9 | 14.6 | 15.6 | 28.5 | 13.2 |