Literature DB >> 31033256

Soft Wearable Pressure Sensors for Beat-to-Beat Blood Pressure Monitoring.

Joshua Kim1, En-Fan Chou2, Jamie Le2, Sabrina Wong2, Michael Chu2, Michelle Khine1,2.   

Abstract

Wrinkled gold thin films on elastomeric substrates are used as robust parallel plate electrodes for soft capacitive pressure sensors. The wrinkled structures create a robust integration with the polymer, allowing repeated normal force to deform the thin film without failure. By incorporating microridged structures that support the counter electrodes to create air cavities within the elastomeric dielectric layer, pressure sensitivity is further increased to 0.148 kPa-1 over a wide dynamic range of up to 10 kPa. The wide dynamic range and pressure sensitivity of the pressure sensor allow for consistent measurements of the pressure exerted by the radial artery located on the wrist. The soft capacitive pressure sensor displays comparable results when tested against an FDA approved device (Clearsight, Edwards Lifesciences, Irvine, CA) measuring beat-to-beat blood pressure. These soft pressure sensors using wrinkled thin films, therefore, illustrate considerable potential to continuously monitor beat-to-beat blood pressure.
© 2019 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  blood pressure; flexible electronics; health sensors; pressure sensors; wearable electronics

Year:  2019        PMID: 31033256     DOI: 10.1002/adhm.201900109

Source DB:  PubMed          Journal:  Adv Healthc Mater        ISSN: 2192-2640            Impact factor:   9.933


  20 in total

1.  Differential cardiopulmonary monitoring system for artifact-canceled physiological tracking of athletes, workers, and COVID-19 patients.

Authors:  Hyoyoung Jeong; Jong Yoon Lee; KunHyuck Lee; Youn J Kang; Jin-Tae Kim; Raudel Avila; Andreas Tzavelis; Joohee Kim; Hanjun Ryu; Sung Soo Kwak; Jong Uk Kim; Aaron Banks; Hokyung Jang; Jan-Kai Chang; Shupeng Li; Chaithanya K Mummidisetty; Yoonseok Park; Simone Nappi; Keum San Chun; Young Joong Lee; Kyeongha Kwon; Xiaoyue Ni; Ha Uk Chung; Haiwen Luan; Jae-Hwan Kim; Changsheng Wu; Shuai Xu; Anthony Banks; Arun Jayaraman; Yonggang Huang; John A Rogers
Journal:  Sci Adv       Date:  2021-05-12       Impact factor: 14.136

Review 2.  Engineering (Bio)Materials through Shrinkage and Expansion.

Authors:  Mian Wang; Wanlu Li; Guosheng Tang; Carlos Ezio Garciamendez-Mijares; Yu Shrike Zhang
Journal:  Adv Healthc Mater       Date:  2021-06-16       Impact factor: 11.092

3.  Inkjet Printed Textile Force Sensitive Resistors for Wearable and Healthcare Devices.

Authors:  Beomjun Ju; Inhwan Kim; Braden M Li; Caitlin G Knowles; Amanda Mills; Landon Grace; Jesse S Jur
Journal:  Adv Healthc Mater       Date:  2021-07-01       Impact factor: 11.092

4.  Hierarchical Network Enabled Flexible Textile Pressure Sensor with Ultrabroad Response Range and High-Temperature Resistance.

Authors:  Meiling Jia; Chenghan Yi; Yankun Han; Lei Wang; Xin Li; Guoliang Xu; Ke He; Nianci Li; Yuxin Hou; Zhongguo Wang; Yuanhao Zhu; Yuanao Zhang; Mingzhu Hu; Ran Sun; Peifei Tong; Jiawei Yang; Yougen Hu; Zhixun Wang; Weimin Li; Wenjie Li; Lei Wei; Chunlei Yang; Ming Chen
Journal:  Adv Sci (Weinh)       Date:  2022-03-14       Impact factor: 17.521

5.  A Wearable Capacitive Sensor Based on Ring/Disk-Shaped Electrode and Porous Dielectric for Noncontact Healthcare Monitoring.

Authors:  Ya-Nan Zheng; Zhe Yu; Guoyong Mao; Yunyao Li; Dhanapal Pravarthana; Waqas Asghar; Yiwei Liu; Shaoxing Qu; Jie Shang; Run-Wei Li
Journal:  Glob Chall       Date:  2020-03-18

6.  Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement.

Authors:  Ting-Wei Wang; Shien-Fong Lin
Journal:  Sensors (Basel)       Date:  2020-02-05       Impact factor: 3.576

7.  Graded intrafillable architecture-based iontronic pressure sensor with ultra-broad-range high sensitivity.

Authors:  Ningning Bai; Liu Wang; Qi Wang; Jue Deng; Yan Wang; Peng Lu; Jun Huang; Gang Li; Yuan Zhang; Junlong Yang; Kewei Xie; Xuanhe Zhao; Chuan Fei Guo
Journal:  Nat Commun       Date:  2020-01-10       Impact factor: 14.919

Review 8.  Advances in Materials for Soft Stretchable Conductors and Their Behavior under Mechanical Deformation.

Authors:  Thao Nguyen; Michelle Khine
Journal:  Polymers (Basel)       Date:  2020-06-29       Impact factor: 4.329

9.  Clinical Validation of a Soft Wireless Continuous Blood Pressure Sensor During Surgery.

Authors:  En-Fan Chou; Shin Yu Celia Cheung; Hailey Christine Maxwell; Nicholas Pham; Michelle Khine; Joseph Rinehart
Journal:  Front Digit Health       Date:  2021-07-22

10.  Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring.

Authors:  Kazuomi Kario
Journal:  Hypertension       Date:  2020-08-03       Impact factor: 10.190

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.