Literature DB >> 31027443

Psychometric evaluation of the Heart Failure Somatic Perception Scale in a European heart failure population.

Gianluca Pucciarelli1, Andrea Greco2, Marco Paturzo1, Corrine Y Jurgens3, Angela Durante1, Rosaria Alvaro1, Ercole Vellone1.   

Abstract

BACKGROUND: The Heart Failure Somatic Perception Scale (HFSPS) is a four-factor instrument used to assess how bothersome are 18 physical signs and symptoms of heart failure. To date, construct validity and reliability of the HFSPS have been evaluated in only one American study and never in a European population. AIM: To evaluate psychometric properties (validity and reliability) of the HFSPS in a European heart failure population.
METHODS: This was an Italian multicentre study in which the HFSPS factorial structure was assessed using confirmatory factor analysis. Criterion related validity of the HFSPS was evaluated by correlating its factor scores with the Kansas City Cardiomyopathy Questionnaire (KCCQ) scores using Pearson's r. The HFSPS internal consistency reliability was evaluated using the factor score determinacy coefficient, Cronbach's α and model-based internal consistency index.
RESULTS: Most of the participants (n=321) were male (56.6%), with a mean age of 71.48 years (SD, 12.75) and in New York Heart Association class II (61.8%). The confirmatory factor analysis, testing the original HFSPS four-factor structure (dyspnoea, chest discomfort, early and subtle, and oedema), resulted in the following supportive fit indices: χ2 (126, N=321)=337.612, p<0.001, comparative fit index =0.920, Tucker-Lewis index =0.903, root mean square error of approximation =0.072 and standardized root mean square residual =0.045. With regard to the criterion related validity, all the correlations with the KCCQ were statistically significant. The HFSPS reliability resulted in factor score determinacy coefficients ⩾ 0.87 and Cronbach's α ⩾ 0.75, with the exception of the two-item chest discomfort subscale; the model-based reliability coefficient was 0.914.
CONCLUSION: The validity and reliability of the HFSPS were supportive in this European sample. The HFSPS can be used to assess how bothersome heart failure signs and symptoms are in order to improve their management.

Entities:  

Keywords:  Heart failure; psychometrics; reliability; signs; symptoms; validity

Mesh:

Year:  2019        PMID: 31027443     DOI: 10.1177/1474515119846240

Source DB:  PubMed          Journal:  Eur J Cardiovasc Nurs        ISSN: 1474-5151            Impact factor:   3.908


  2 in total

1.  A New Strategy for Identification of Coal Miners With Abnormal Physical Signs Based on EN-mRMR.

Authors:  Mengran Zhou; Kai Bian; Feng Hu; Wenhao Lai
Journal:  Front Bioeng Biotechnol       Date:  2022-07-11

2.  Symptom Perception and Influencing Factors in Chinese Patients with Heart Failure: A Preliminary Exploration.

Authors:  Hong Luo; Deborah F Lindell; Corrine Y Jurgens; Yongsheng Fan; Liping Yu
Journal:  Int J Environ Res Public Health       Date:  2020-04-14       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.