Literature DB >> 31026556

Systematic Review of Intensity-Modulated Brachytherapy (IMBT): Static and Dynamic Techniques.

Cameron M Callaghan1, Quentin Adams1, Ryan T Flynn1, Xiaodong Wu2, Weiyu Xu3, Yusung Kim4.   

Abstract

PURPOSE: To systematically review scientific literature on the use of intensity-modulated brachytherapy (IMBT), including static and dynamic shielding approaches, to enhance therapeutic ratio. Studies were evaluated for technique, disease site, dosimetry, applicators, dosimetric calculations, and planning algorithms. Comparisons with standard-of-care brachytherapy techniques, alternative IMBT methods, or both were performed for dose-to-target volumes, organs at risk (OARs), and treatment planning or delivery times. METHODS AND MATERIALS: Inclusion criteria were any peer-reviewed journal articles on IMBT published from January 1, 1980, to January 1, 2019, on PubMed, Google Scholar, Cochrane Library, and EBSCO databases. Two independent investigators reviewed each article for inclusion and exclusion criteria and scope. Data collected on each study included technique, source or shield material, disease site, n of study (n = number of simulated plans/treated patients), dose-to-target/OARs, and planning or delivery times. This review adhered to the Preferred Reporting Items for Systemic reviews and Meta Analyses (PRISMA).
RESULTS: Database queries yielded 1734 results, which were reduced to 436 after exclusion criteria and 78 peer-reviewed journal articles after evaluation of scope. Studies per disease site were 31 for cervical; 16 for rectal; 10 for oculocutaneous; 7 for breast; 6 for prostate; and 8 for other, multiple, or no specific disease site. Eighteen studies demonstrated a significant decrease in dose to OARs (5.1%-68.2%), 11 improved treatment planning or delivery times (7.6%-99.7%), and 6 increased target coverage (18.6%-71.6%) relative to standard-of-care or alternative IMBT technique. IMBT consistently decreased dose to OAR compared with the standard of care at the cost of increased planning or delivery times. Innovations in dose calculation or planning algorithms and applicators were capable of ameliorating prolonged treatment intervals.
CONCLUSIONS: IMBT techniques improved the therapeutic ratio by reducing OAR doses, facilitating dose escalation, or both. Static-shielding techniques are clinically available as a result of the advent of commercially available heterogeneity-corrected dose-calculation algorithms, whereas dynamic-shielding techniques are still preclinical. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2019        PMID: 31026556     DOI: 10.1016/j.ijrobp.2019.04.009

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  Comparing multichannel cylinder and 3D-printed applicators for vaginal cuff brachytherapy with preliminary exploration of post-hysterectomy vaginal morphology.

Authors:  Junfang Yan; Xue Qin; Fuquan Zhang; Xiaorong Hou; Lang Yu; Jie Qiu
Journal:  J Contemp Brachytherapy       Date:  2021-12-30

2.  Radiobiological evaluation of organs at risk for electronic high-dose-rate brachytherapy in uveal melanoma: a radiobiological modeling study.

Authors:  Timothy J Waldron; Bryan G Allen; Edward Pennington; H Culver Boldt; Yusung Kim
Journal:  J Contemp Brachytherapy       Date:  2021-10-29

3.  Intensity Modulated High Dose Rate (HDR) Brachytherapy Using Patient Specific 3D Metal Printed Applicators: Proof of Concept.

Authors:  James J Sohn; Mitchell Polizzi; Sang-Won Kang; Woo-Hyeong Ko; Yong-Hyun Cho; Keun-Yong Eom; Jin-Beom Chung
Journal:  Front Oncol       Date:  2022-02-10       Impact factor: 5.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.