Literature DB >> 31026432

Survival After Mitral Valve Replacement for Leaflet Escape in a Contemporary On-X Mechanical Valve.

Carlos Amorós Rivera1, Francisco Javier López Rodríguez2, María Elena Arnáiz García2, Ramón Adolfo Arévalo Abascal2, Ana María Barral Varela2, Myriel Mayelinne López Tatis2, José A Sastre3, Francisco Lozano Sánchez4, José Ángel Torres Hernández4, José María González Santos2.   

Abstract

Leaflet escape in contemporary mechanical valves is an extremely rare and potentially lethal condition. We report the case of a 77-year-old man who presented with embolization of a leaflet from an On-X mitral valve (CryoLife, Kennesaw, GA) with Conform-X Sewing Ring prosthesis (CryoLife) after exercise. The patient recovered completely 6 months after surgery, and he is currently asymptomatic.
Copyright © 2019 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31026432     DOI: 10.1016/j.athoracsur.2019.03.064

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  On-X mitral valve leaflet embolization presenting as acute pulmonary oedema.

Authors:  Lindiwe Sidali; Nandipha Ndibi; Manogran Moopanar; Rajhmun Madansein
Journal:  Egypt Heart J       Date:  2022-05-04

2.  Commentary: How can you mend a broken heart: Mechanical valve leaflet fracture.

Authors:  Parth M Patel; Edward P Chen
Journal:  JTCVS Tech       Date:  2020-06-30

3.  Leaflet fracture and embolization from an On-X mechanical mitral valve.

Authors:  Erik Helgeland; Kristoffer Andresen; Karl Andreas Dumont; Johannes Lagethon Bjørnstad
Journal:  JTCVS Tech       Date:  2020-06-24