Literature DB >> 31026009

Redox-probe-free scanning electrochemical microscopy combined with fast Fourier transform electrochemical impedance spectroscopy.

Aušra Valiūnienė1, Jurate Petroniene, Inga Morkvenaite-Vilkonciene, Georgi Popkirov, Almira Ramanaviciene, Arunas Ramanavicius.   

Abstract

Scanning electrochemical microscopy (SECM) hybridized with fast Fourier transform-based electrochemical impedance spectroscopy (FFT-EIS) seems to be a powerful variation of scanning electrochemical impedance microscopy (SEIM), wherein both state-of-the-art techniques are combined (FFT-SEIM) and can be used for the investigation and treatment of tissues at single cell level. However, in most EIS-based experiments, harmful redox mediators are applied, which affect the functioning of living cells and tissues. Therefore, the development of a redox-probe-free FFT-SEIM is still a very important challenge in electrochemistry. For this reason, in this research, we have demonstrated a redox-probe-free evaluation of conducting and non-conducting surfaces by combining scanning electrochemical microscopy with FFT-EIS. It was demonstrated that using the fast Fourier transform-based FFT-EIS technique, EIS spectra could be registered much faster compared to experiments performed using the conventional EIS equipment. An ultramicroelectrode (UME) was used as a scanning electrode to ensure high spatial resolution. We have performed FFT-SEIM measurements in a redox-probe-free mode (without any additional redox probes) and have investigated several surfaces with different conductivities. The FFT-EIS equipment and the built-in software help to avoid the influence of possible formation of hydrogen bubbles on the UME. This research opens up a new avenue for the application of FFT-SEIM in the investigation of samples that are unstable and very sensitive towards redox mediators (e.g., tissues and/or living cells).

Entities:  

Year:  2019        PMID: 31026009     DOI: 10.1039/c9cp00187e

Source DB:  PubMed          Journal:  Phys Chem Chem Phys        ISSN: 1463-9076            Impact factor:   3.676


  3 in total

1.  Correlation between Tafel Analysis and Electrochemical Impedance Spectroscopy by Prediction of Amperometric Response from EIS.

Authors:  Kyungsoon Park; Byoung-Yong Chang; Seongpil Hwang
Journal:  ACS Omega       Date:  2019-11-08

2.  Scanning Probe Microscopy Facility for Operando Study of Redox Processes on Lithium ion Battery Electrodes.

Authors:  W J Legerstee; M Boekel; S Boonstra; E M Kelder
Journal:  Front Chem       Date:  2021-04-15       Impact factor: 5.221

Review 3.  Towards application of CRISPR-Cas12a in the design of modern viral DNA detection tools (Review).

Authors:  Julija Dronina; Urte Samukaite-Bubniene; Arunas Ramanavicius
Journal:  J Nanobiotechnology       Date:  2022-01-21       Impact factor: 10.435

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.