Literature DB >> 31021715

Critical investigation of glove-gown interface barrier performance in simulated surgical settings.

Zafer Kahveci1, F Selcen Kilinc-Balci1, Patrick L Yorio1.   

Abstract

The barrier properties of personal protective equipment are vital to healthcare personnel to protect themselves from possible infectious body fluids. Intraoperative exposure of healthcare personnel to body fluids can be substantial in both inpatient and outpatient settings. The glove-gown interface is known as one of the weakest points of the whole personal protective equipment system. However, there is a lack of scientific research designed to investigate the problem. This paper reports the results of experiments using a new testing methodology developed to quantify fluid leakage through the glove-gown interface while simulating surgical settings in terms of operating room personnel activities, exposure types, exposure durations, and physical stresses applied on the interface. This study represents one of the first efforts investigating the amount of fluid leakage through the glove-gown interface for a number of surgical gown and glove models while considering glove material differences and single vs. double gloving. The test results showed that there is a significant difference in fluid leakage amounts between three gown models and four glove models studied. The results also demonstrated that double gloving significantly reduced the fluid leakage compared to single glove use. The mean fluid leakage was lower in the double synthetic glove configurations (M = 2.76g) compared with all other configurations (3GLV, M = 8.3g; 4GLV, M = 9.49g; 5GLV, M = 3.08g; 6GLV, M = 20.03g; double latex, M = 5.22g). Findings highlighted a significant interaction between glove and gown designs, which suggests that gown and gloves should be designed together as a system to minimize or eliminate the fluid leakage.

Entities:  

Keywords:  Glove; gown; interface; penetration; personal protective equipment; surgical settings

Mesh:

Year:  2019        PMID: 31021715     DOI: 10.1080/15459624.2019.1600702

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  A Combined Tie-Fastening Method for the Reusable Surgical Gown with Two Neck Tie Belts to Improve Wearing Comfort.

Authors:  Kai-Hui Chang; Yu-Ling Chen; Shu-Yi Dai
Journal:  Nurs Rep       Date:  2020-11-16

2.  Intraoperative damage to surgical gloves during various operations on the musculoskeletal system: a multicenter study.

Authors:  Andreas Enz; Tanja Kostuj; Philipp Warnke; Katrin Osmanski-Zenk; Wolfram Mittelmeier; Annett Klinder
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-29       Impact factor: 3.067

3.  Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.

Authors:  Jos H Verbeek; Blair Rajamaki; Sharea Ijaz; Riitta Sauni; Elaine Toomey; Bronagh Blackwood; Christina Tikka; Jani H Ruotsalainen; F Selcen Kilinc Balci
Journal:  Cochrane Database Syst Rev       Date:  2020-04-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.