Literature DB >> 3102069

Cardiovascular computed tomography (cine CT) of abnormal left ventricular wall motion due to epicardial pacing electrodes.

R S Altin, S Flicker, H J Naidech, W J Eldredge.   

Abstract

A patient with an abnormal cardiac silhouette on chest X-ray was studied by fast cardiovascular computed tomography (cine CT). The location of epicardial pacing electrodes and their relationship to myocardial wall motion abnormalities were examined. This eliminated the need for cardiac catheterization.

Entities:  

Mesh:

Year:  1987        PMID: 3102069     DOI: 10.1007/bf02583297

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  9 in total

1.  Fatal outcome arising from use of a sutureless "corkscrew" epicardial pacing electrode inserted into apex of left ventricle.

Authors:  R J Vecht; C J Fontaine; J W Bradfield
Journal:  Br Heart J       Date:  1976-12

2.  Subepicardial infarction, myocardial impression, and ventricular penetration by sutureless electrode and leads.

Authors:  W E Steinke; F T Thomas; Z ul Hassan; R A Mendoza; A S Gear
Journal:  Chest       Date:  1976-07       Impact factor: 9.410

3.  Computed tomographic localization of malposition of pacing electrodes: the value of cardiovascular computed tomography.

Authors:  S Flicker; W J Eldredge; H J Naidech; R M Steiner; D L Clark
Journal:  Pacing Clin Electrophysiol       Date:  1985-07       Impact factor: 1.976

4.  Further evaluation of the sutureless, screw-in electrode for cardiac pacing. Experience with first 300 implantations.

Authors:  K A Mansour; J I Miller; P N Symbas; C R Hatcher
Journal:  J Thorac Cardiovasc Surg       Date:  1979-06       Impact factor: 5.209

5.  Permanent cardiac pacing with sutureless myocardial electrodes: experience in first one hundred patients.

Authors:  P J de Feyter; P A Majid; H F Hoitsma; W Stroes; J P Roos
Journal:  Pacing Clin Electrophysiol       Date:  1980-03       Impact factor: 1.976

6.  Two-dimensional echocardiographic identification of epicardial pacemaker wire perforation.

Authors:  R A Chazal; H Feigenbaum
Journal:  Am Heart J       Date:  1984-01       Impact factor: 4.749

7.  Ten-year experience of 359 epicardial pacemaker systems: complications and results.

Authors:  P J Oldershaw; M G Sutton; D Ward; S Jones; G A Miller
Journal:  Clin Cardiol       Date:  1982-10       Impact factor: 2.882

8.  Epicardial corkscrew lead fracture: an underreported cause of pacing failure?

Authors:  W H Fleming; L B Sarafian; J W Yarbrough; J D Kugler; P K Mooring
Journal:  Ann Thorac Surg       Date:  1983-05       Impact factor: 4.330

9.  Real-time, two-dimensional echocardiographic features of pacemaker perforation.

Authors:  B Gondi; N C Nanda
Journal:  Circulation       Date:  1981-07       Impact factor: 29.690

  9 in total