Literature DB >> 31019744

Problems with using the air leak test with Yang's bubble solution during video-assisted thoracic surgery.

Hideki Kawai1.   

Abstract

Entities:  

Year:  2019        PMID: 31019744      PMCID: PMC6462690          DOI: 10.21037/jtd.2019.02.44

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


× No keyword cloud information.
  8 in total

Review 1.  Can a standardised Ventilation Mechanical Test for quantitative intraoperative air leak grading reduce the length of hospital stay after video-assisted thoracoscopic surgery lobectomy?

Authors:  Francesco Zaraca; Maurizio Vaccarili; Gino Zaccagna; Pio Maniscalco; Giampiero Dolci; Birgit Feil; Reinhold Perkmann; Luca Bertolaccini; Roberto Crisci
Journal:  J Vis Surg       Date:  2017-12-07

2.  Intraoperative air leak measured after lobectomy is associated with postoperative duration of air leak.

Authors:  Alessandro Brunelli; Michele Salati; Cecilia Pompili; Paolo Gentili; Armando Sabbatini
Journal:  Eur J Cardiothorac Surg       Date:  2017-11-01       Impact factor: 4.191

3.  Prevention of alveolar air leakage after video-assisted thoracic surgery: comparison of the efficacy of methods involving the use of fibrin glue.

Authors:  Hideki Kawai; Kenji Harada; Hideki Ohta; Takeshi Tokushima; Shiro Oka
Journal:  Thorac Cardiovasc Surg       Date:  2011-12-29       Impact factor: 1.827

4.  Air leaks after lobectomy increase the risk of empyema but not of cardiopulmonary complications: a case-matched analysis.

Authors:  Alessandro Brunelli; Francesco Xiume; Majed Al Refai; Michele Salati; Rita Marasco; Armando Sabbatini
Journal:  Chest       Date:  2006-10       Impact factor: 9.410

5.  Clinical outcome and risk factors for complications after pulmonary segmentectomy by video-assisted thoracoscopic surgery: results of an initial experience.

Authors:  Benoît Bédat; Etienne Abdelnour-Berchtold; Thorsten Krueger; Jean Yannis Perentes; Hans-Beat Ris; Frédéric Triponez; Marc-Joseph Licker; Wolfram Karenovics; Michel Gonzalez
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

6.  Natural air leak test without submergence for spontaneous pneumothorax.

Authors:  Hidetaka Uramoto; Fumihiro Tanaka
Journal:  J Cardiothorac Surg       Date:  2011-12-24       Impact factor: 1.637

7.  Impact of Powered and Tissue-Specific Endoscopic Stapling Technology on Clinical and Economic Outcomes of Video-Assisted Thoracic Surgery Lobectomy Procedures: A Retrospective, Observational Study.

Authors:  Daniel L Miller; Sanjoy Roy; Edmund S Kassis; Sashi Yadalam; Sushama Ramisetti; Stephen S Johnston
Journal:  Adv Ther       Date:  2018-04-16       Impact factor: 3.845

8.  Preclinical quantification of air leaks in a physiologic lung model: effects of ventilation modality and staple design.

Authors:  Chad E Eckert; Jason L Harris; Jordan B Wong; Suzanne Thompson; Edmund S Kassis; Masahiro Tsuboi; Harald C Ott; Seth Force
Journal:  Med Devices (Auckl)       Date:  2018-12-14
  8 in total
  1 in total

1.  A novel air leak test using surfactant: a step forward or a bubble that will burst?

Authors:  Michael Eberlein; Natalie Baldes; Servet Bölükbas
Journal:  J Thorac Dis       Date:  2019-05       Impact factor: 2.895

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.