Stent-Graft Length Is Associated with Decreased Patency in Treatment of Central Venous Stenosis in Hemodialysis Patients.

Mina L Boutrous1, Alejandro C Alvarez2, Obi T Okoye1, Jennifer C Laws1, Donald L Jacobs1, Matthew R Smeds3.   

Abstract

BACKGROUND: Central venous occlusion may occur in hemodialysis patients, resulting in arm or facial swelling and failure of dialysis access. Endovascular management with balloon angioplasty or stenting has been described, but there are minimal data on the use of covered stents in this pathology. We sought to review a single institution's experience with the use of covered stents for central venous occlusive disease in hemodialysis patients.
METHODS: A retrospective review of all patients undergoing placement of covered stents between April 2014 and December 2016 for central venous occlusive disease to preserve a failing dialysis access was performed. Patients' records were reviewed to identify demographics, medical comorbidities, operative variables, primary patency rates, and secondary interventions.
RESULTS: A total of 29 patients were included in the analysis. Viabahn (W.L. Gore and Associates, Flagstaff, AZ) stent grafts were exclusively used in all patients. Technical success rate was 100%. The patients were predominantly female (65.5%), with a mean age of 67.9 ± 12.1 and medical comorbidities of hypertension (86%), diabetes (76%), and tobacco use (7%). The majority (86%) had prior angioplasty and 17 of 29 (59%) patients had previous central venous catheters. The right brachiocephalic vein was the most commonly stented vessel (28%). The median stent length and diameter used were 50 millimeters (range 25-100 millimeters) and 13 millimeters (range: 9-13 millimeters), respectively. The majority of patients (83%) received a single stent, with only 2 patients requiring more than one. Median follow-up was 24 months (range: 6-41 months). Four of 29 (13.8%) patients developed symptomatic stent restenosis requiring secondary intervention, all of which occurred in patients with primary stenosis between 50% and 75%. When compared to the patients without restenosis, longer stents were found to be significantly associated with restenosis (62.5 centimeters, interquartile range [IQR]: 0] vs. 50 centimeter, IQR: 0, P = 0.002). Primary patency rates were 92.9%, 91.7%, and 80.0% at 6, 12, and 24 months respectively. Secondary patency rates were 96.4%, 95.8%, and 93.3% at 6 months, 12 months, and 24 months, respectively. The overall primary patency rate was estimated at 86.2% using Kaplan-Meier analysis at 30.5 months (95% confidence interval: 26.5-34.5 months).
CONCLUSIONS: Covered stent grafts have reasonable primary patency and excellent secondary patency when used for central venous stenosis in dialysis patients. Stent-graft length is associated with poorer long-term patency rates.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31009722     DOI: 10.1016/j.avsg.2019.01.024

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  3 in total

1.  Efficacy and safety of recanalization with transseptal needle for chronic total occlusion of the brachiocephalic vein in hemodialysis patients.

Authors:  Xi Yin; Xi Shen; Zhongxin Zhou; Qin Chen; Li Zhou; Tianlei Cui
Journal:  Ann Transl Med       Date:  2020-09

2.  Stent patency rates and prognostic factors of endovascular intervention for iliofemoral vein occlusion in post-thrombotic syndrome.

Authors:  Rencong Chen; Ruijia Feng; Suiting Jiang; Guangqi Chang; Zuojun Hu; Chen Yao; Benyuan Jia; Shenming Wang; Siwen Wang
Journal:  BMC Surg       Date:  2022-07-12       Impact factor: 2.030

3.  Iliocaval reconstruction of chronically thrombosed cylindrical inferior vena cava filters with balloon expandable covered stent-grafts.

Authors:  Mohamed Elboraey; Beau B Toskich; Andrew R Lewis; Charles A Ritchie; Gregory T Frey; Zlatko Devcic
Journal:  J Vasc Surg Cases Innov Tech       Date:  2021-05-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.