Literature DB >> 31008680

Influence of Luting Materials and Methods and the Restoration Surface on the Amount of Cement Remnants in Implant Restorations.

Jae-Hyun Lee1, Sung-Eun Yang2, Jungwon Lee3, Su-Young Lee4.   

Abstract

This study aimed to investigate the effects of the luting methods on the amount of cement remnants in implant restorations and to determine the restoration surface with the maximum amount of residual cement. Forty abutments and crowns were divided into 4 groups as follows: TB group, luting with zinc oxide-eugenol cement; TBV group, luting with zinc oxide-eugenol cement after application of a separating agent over the transmucosal area of the abutment; PI group, luting with methacrylate cement; and PIV group, luting with methacrylate cement after application of a separating agent. After cementation, all the quadrants of the specimens were photographed, and the amount and location of the cement remnants were statistically analyzed (P ≤ .05). The amount of cement remnants was significantly smaller in the groups with a separating agent. The type of luting material did not significantly affect the results. Cement remnants were more abundant on the mesial and distal sides than on the buccal and lingual sides of the restoration.

Entities:  

Keywords:  cement-retained implant restorations; dental cement; dental implant; excess cement; peri-implantitis

Mesh:

Substances:

Year:  2019        PMID: 31008680     DOI: 10.1563/aaid-joi-D-18-00283

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study.

Authors:  Yeon-Hee Park; Kyoung-A Kim; Jung-Jin Lee; Tae-Min Kwon; Jae-Min Seo
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

2.  Esthetic Evaluation and Acceptability of Different Hole Designs on Implant Crowns from the Perspective of Patients and Dentists in China.

Authors:  Cai Wen; Rong Jiang; Zhiqiang Zhang; Bo Lei; Yingquan Zhong; Huangjun Zhou
Journal:  Patient Prefer Adherence       Date:  2022-02-17       Impact factor: 2.711

3.  Finite Element Analysis of Dental Implants with Zirconia Crown Restorations: Conventional Cement-Retained vs. Cementless Screw-Retained.

Authors:  Jae-Hyun Lee; Ho Yeol Jang; Su Young Lee
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.