Literature DB >> 31005773

An FPSE-HPLC-PDA method for rapid determination of solar UV filters in human whole blood, plasma and urine.

Marcello Locatelli1, Kenneth G Furton2, Angela Tartaglia3, Elena Sperandio3, Halil I Ulusoy4, Abuzar Kabir5.   

Abstract

This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of six benzophenone derivative UV filters including benzophenone (BZ); 5-benzoyl-4-hydroxy-methoxybenzenesulfonic acid (BP-4); bis(4-hydroxyphenyl)methanone (4-DHB); bis(2,4-dihydroxyphenyl)methanone (BP-2); (2,4-dihydroxybenzophenone) (BP-1) and 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) in human whole blood, plasma and urine samples. Chromatographic separation method was conducted using a Spherisorb ODS 1 (C18) column in isocratic elution mode with a run time <25 min. The FPSE-HPLC-PDA method was validated in the range from 0.1 to 10 μg/mL for all the UV filter compounds. Propyl 4-hydroxybenzoate (also known as propyl paraben) was used as the internal standard (IS). The limit of quantification was found to be 0.1 μg/mL and the weighted-matrix matched standard calibration curves of six UV filters showed a good linearity up to a concentration of 10 μg/mL. This new approach exhibits high potential for direct adaptation as a rapid, robust and green analytical tool for several applications, e.g. in the current sample preparation practices used in many bioanalytical fields including pharmacokinetics (PK), pharmacodynamics (PD), therapeutic drug monitoring (TDM), clinical and forensic toxicology, disease diagnosis and drug discovery. Additionally, in the present work was highlighted that applying innovative extraction and clean up procedures before instrumental analysis by means of a well-known, rugged, cheap, and diffused configurations (e.g. HPLC-PDA), could be possible to validate methods that shows analytical performances comparable to more expensive and complex instrumentations (e.g. LC-MS/MS) that require trained personnel, high maintenance costs and a deep knowledge of analytical problems that could be encountered.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Benzophenone-derivative UV filters; Clinical and diagnostic applications; FPSE-HPLC-PDA; Human exposure; Method validation; Plasma and urine; Whole blood

Mesh:

Substances:

Year:  2019        PMID: 31005773     DOI: 10.1016/j.jchromb.2019.04.028

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  7 in total

1.  Evaluation of heavy metals in cosmetic products and their health risk assessment.

Authors:  Hamna Arshad; Moniba Zahid Mehmood; Munir Hussain Shah; Arshad Mehmood Abbasi
Journal:  Saudi Pharm J       Date:  2020-05-29       Impact factor: 4.330

Review 2.  Fabric Phase Sorptive Extraction: A Paradigm Shift Approach in Analytical and Bioanalytical Sample Preparation.

Authors:  Abuzar Kabir; Victoria Samanidou
Journal:  Molecules       Date:  2021-02-06       Impact factor: 4.411

3.  Fabric phase sorptive extraction combined with gas chromatography-mass spectrometry as an innovative analytical technique for the determination of selected polycyclic aromatic hydrocarbons in herbal infusions and tea samples.

Authors:  Natalia Manousi; Abuzar Kabir; Kenneth G Furton; Erwin Rosenberg; George A Zachariadis
Journal:  RSC Adv       Date:  2022-03-01       Impact factor: 3.361

4.  The photooxidative sensitization of bis(p-substituted diphenyl)iodonium salts in the radical polymerization of acrylates.

Authors:  Alicja Balcerak; Janina Kabatc
Journal:  RSC Adv       Date:  2019-09-10       Impact factor: 3.361

5.  Ethanol Determination in Post-Mortem Samples: Correlation between Blood and Vitreous Humor Concentration.

Authors:  Fabio Savini; Angela Tartaglia; Ludovica Coccia; Danilo Palestini; Cristian D'Ovidio; Ugo de Grazia; Giuseppe Maria Merone; Elisa Bassotti; Marcello Locatelli
Journal:  Molecules       Date:  2020-06-12       Impact factor: 4.411

6.  Novel MIPs-Parabens based SPE Stationary Phases Characterization and Application.

Authors:  Angela Tartaglia; Abuzar Kabir; Songul Ulusoy; Halil Ibrahim Ulusoy; Giuseppe Maria Merone; Fabio Savini; Cristian D'Ovidio; Ugo de Grazia; Serena Gabrielli; Fabio Maroni; Pantaleone Bruni; Fausto Croce; Dora Melucci; Kenneth G Furton; Marcello Locatelli
Journal:  Molecules       Date:  2019-09-13       Impact factor: 4.411

7.  Evaluation of a high-performance liquid chromatography method for urinary oxalate determination and investigation regarding the pediatric reference interval of spot urinary oxalate to creatinine ratio for screening of primary hyperoxaluria.

Authors:  Ying Shen; Xia Luo; Huijun Li; Qing Guan; Liming Cheng
Journal:  J Clin Lab Anal       Date:  2021-06-07       Impact factor: 2.352

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.