Literature DB >> 31003218

Validation of a freehand technique for cortical bone trajectory screws in the lumbar spine.

Zachary Tan1, Stewart McLachlin2,3, Cari Whyne1,2, Joel Finkelstein1,2.   

Abstract

OBJECTIVEThe cortical bone trajectory (CBT) technique for pedicle screw placement has gained popularity among spinal surgeons. It has been shown biomechanically to provide better fixation and improved pullout strength compared to a traditional pedicle screw trajectory. The CBT technique also allows for a less invasive approach for fusion and may have lower incidence of adjacent-level disease. A limitation of the current CBT technique is a lack of readily identifiable and reproducible visual landmarks to guide freehand CBT screw placement in comparison to the well-defined identifiable landmarks for traditional pedicle screw insertion. The goal of this study was to validate a safe and intuitive freehand technique for placement of CBT screws based on optimization of virtual CBT screw placement using anatomical landmarks in the lumbar spine. The authors hypothesized that virtual identification of anatomical landmarks on 3D models of the lumbar spine generated from CT scans would translate to a safe intraoperative freehand technique.METHODSCustomized, open-source medical imaging and visualization software (3D Slicer) was used in this study to develop a workflow for virtual simulation of lumbar CBT screw insertion. First, in an ex vivo study, 20 anonymous CT image series of normal and degenerative lumbar spines and virtual screw insertion were conducted to place CBT screws bilaterally in the L1-5 vertebrae for each image volume. The optimal safe CBT trajectory was created by maximizing both the screw length and the cortical bone contact with the screw. Easily identifiable anatomical surface landmarks for the start point and trajectory that best allowed the reproducible idealized screw position were determined. An in vivo validation of the determined landmarks from the ex vivo study was then performed in 10 patients. Placement of virtual "test" cortical bone trajectory screws was simulated with the surgeon blinded to the real-time image-guided navigation, and the placement was evaluated. The surgeon then placed the definitive screw using image guidance.RESULTSFrom the ex vivo study, the optimized technique and landmarks were similar in the L1-4 vertebrae, whereas the L5 optimized technique was distinct. The in vivo validation yielded ideal, safe, and unsafe screws in 62%, 16%, and 22% of cases, respectively. A common reason for the nonidealized trajectories was the obscuration of patient anatomy secondary to severe degenerative changes.CONCLUSIONSCBT screws were placed ideally or safely 78% of the time in a virtual simulation model. A 22% rate of unsafe freehand trajectories suggests that the CBT technique requires use of image-guided navigation or x-ray guidance and that reliable freehand CBT screw insertion based on anatomical landmarks is not reliably feasible in the lumbar spine.

Entities:  

Keywords:  CBT = cortical bone trajectory; LIS = less invasive surgery; cortical bone trajectory; freehand technique; image guidance; lumbar; pedicle screw; surgical technique

Year:  2019        PMID: 31003218     DOI: 10.3171/2019.1.SPINE181402

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  2 in total

1.  Effects of Revision Rod Position on Spinal Construct Stability in Lumbar Revision Surgery: A Finite Element Study.

Authors:  Quan-Chang Tan; Jin-Feng Huang; Hao Bai; Zi-Xuan Liu; Xin-Yi Huang; Xiong Zhao; Zhao Yang; Cheng-Fei Du; Wei Lei; Zi-Xiang Wu
Journal:  Front Bioeng Biotechnol       Date:  2022-01-05

2.  Predictors of accurate intrapedicular screw placement in single-level lumbar (L4-5) fusion: robot-assisted pedicle screw, traditional pedicle screw, and cortical bone trajectory screw insertion.

Authors:  Hua-Qing Zhang; Can-Can Wang; Ren-Jie Zhang; Lu-Ping Zhou; Chong-Yu Jia; Peng Ge; Cai-Liang Shen
Journal:  BMC Surg       Date:  2022-07-24       Impact factor: 2.030

  2 in total