Literature DB >> 31002279

A systematic follow-up protocol achieving a low hemodialysis graft thrombosis rate.

Pilar Caro Acevedo1, Rosa Marchante1, Israel J Thuissard2, David Sanz-Rosa2, Raquel Amann1, Beatriz Hernandez1, Ramón Delgado1.   

Abstract

INTRODUCTION: Graft is an alternative to native arteriovenous fistula to ensure permanent vascular access in hemodialysis patients. The most common complication is significant stenosis, which frequently causes thrombosis and graft loss. Periodic monitoring and surveillance with elective correction of stenotic lesions can prolong graft survival.
OBJECTIVE: To describe the effect of early diagnosis of significant stenosis on the rate of thrombosis and graft patency.
METHODS: Retrospective, observational study of a cohort of 86 prevalent patients undergoing hemodialysis with a graft as their vascular access. We applied a systematic follow-up protocol of 115 grafts based on various screening methods of monitoring (clinical monitoring, pre-pump arterial pressure, dynamic venous pressure, percentage of recirculation, and dose of dialysis) in conjunction with surveillance (normalized intra-access venous pressure and access flow). The annual rates of thrombosis, and primary, primary-assisted, and secondary patency were assessed.
RESULTS: The incidence of significant stenosis and thrombosis was 57.4% (65/115) and 39.0% (45/115), respectively. Of all screening procedures, normalized intra-access venous pressure was the best predictor of significant stenosis (hazards ratio, 7.71; 95% confidence interval, 3.06-19.46). The annual rate of thrombosis fluctuated from 0 to 0.26 thromboses/patient/year, with an average rate of 0.14 thromboses/patient/year. Primary, primary-assisted, and secondary patency were 74%/79%/82%, 50%/60%/66%, and 23%/35%/37% at 1, 2, and 5 years, respectively.
CONCLUSION: The implementation of a systematic graft follow-up protocol combined with monitoring and surveillance enabled early diagnosis and elective correction of significant stenosis, prolonged graft patency, and a low thrombosis rate.

Entities:  

Keywords:  Graft; monitoring; significant stenosis; surveillance; thrombosis

Mesh:

Year:  2019        PMID: 31002279     DOI: 10.1177/1129729819838795

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  1 in total

1.  Application Value and Relevance Analysis of the Risk Evaluation System for Arteriovenous Fistula Puncture in Thrombosis after Puncture.

Authors:  Mei Li; Chao Sun; Xuan Du
Journal:  J Healthc Eng       Date:  2021-12-02       Impact factor: 2.682

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.