Implementing safe and robust Total Marrow Irradiation using Helical Tomotherapy - A practical guide.

André Haraldsson1, Jacob Engellau2, Stig Lenhoff3, Silke Engelholm3, Sven Bäck3, Per E Engström3.   

Abstract

Total Marrow Irradiation (TMI) with Helical Tomotherapy is a radiotherapy treatment technique that targets bone marrow and sanctuary sites prior to stem cell or bone marrow transplantation (SCT/BMT). TMI is a complex procedure that involves several critical steps that all need to be carefully addressed for a successful implementation, such as dose homogeneity in field junctions, choice of target margins, integrity of treatment and back-up planning. In this work we present our solution for a robust and reproducible workflow throughout the treatment chain and data for twenty-three patients treated to date. MATERIAL &
METHODS: Patients were immobilized in a whole body vacuum cushion and thermoplastic mask. CT-scanning and treatment were performed in two parts with field matching at the upper thigh. Target consisted of marrow containing bone and sanctuary sites. Lungs, kidneys, bowel, heart and liver were defined as organs at risk (OAR). A fast surface scanning system was used to position parts of the body not covered by the imaging system (MVCT) as well as to reduce treatment time.
RESULTS: All patients completed their treatment and could proceed with SCT/BMT. Doses to OARs were significantly reduced and target dose homogeneity was improved compared to TBI. Robustness tests performed on field matching and patient positioning support that the field junction technique is adequate. Replacing MVCT with optical surface scanning reduced the treatment time by 25 min per fraction.
CONCLUSION: The methodology presented here has shown to provide a safe, robust and reproducible treatment for Total Marrow Irradiation using Tomotherapy.
Copyright © 2019 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Helical; Irradiation; Marrow; Radiotherapy; TMI; Tomotherapy; Total

Mesh:

Year:  2019        PMID: 31000078     DOI: 10.1016/j.ejmp.2019.03.032

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  7 in total

1.  The effects of rotational setup errors in total body irradiation using helical tomotherapy.

Authors:  Akira Isobe; Keisuke Usui; Naoya Hara; Keisuke Sasai
Journal:  J Appl Clin Med Phys       Date:  2021-05-24       Impact factor: 2.102

2.  Feasibility of hybrid TomoHelical- and TomoDirect-based volumetric gradient matching technique for total body irradiation.

Authors:  Chae-Seon Hong; Min-Joo Kim; Jihun Kim; Kyung Hwan Chang; Kwangwoo Park; Dong Wook Kim; Min Cheol Han; Hong In Yoon; Jin Sung Kim; Ho Lee
Journal:  Radiat Oncol       Date:  2019-12-19       Impact factor: 3.481

3.  Surface-guided tomotherapy improves positioning and reduces treatment time: A retrospective analysis of 16 835 treatment fractions.

Authors:  André Haraldsson; Sofie Ceberg; Crister Ceberg; Sven Bäck; Silke Engelholm; Per E Engström
Journal:  J Appl Clin Med Phys       Date:  2020-06-26       Impact factor: 2.102

4.  Optimized Conformal Total Body Irradiation methods with Helical TomoTherapy and Elekta VMAT: Implementation, Imaging, Planning and Dose Delivery for Pediatric Patients.

Authors:  Anna Anzorovna Loginova; Diana Anatolievna Tovmasian; Anastasiya Olegovna Lisovskaya; Daria Alexeevna Kobyzeva; Michael Alexandrovich Maschan; Alexander Petrovich Chernyaev; Oleg Borisovich Egorov; Alexey Vladimirovich Nechesnyuk
Journal:  Front Oncol       Date:  2022-03-10       Impact factor: 6.244

5.  Clinical study of total bone marrow combined with total lymphatic irradiation pretreatment based on tomotherapy in hematopoietic stem cell transplantation of acute leukemia.

Authors:  Fanyang Kong; Shuaipeng Liu; Lele Liu; Yifei Pi; Yuntong Pei; Dandan Xu; Fei Jia; Bin Han; Yuexin Guo
Journal:  Front Oncol       Date:  2022-08-11       Impact factor: 5.738

6.  Preclinical validation and treatment of volumetric modulated arc therapy based total bone marrow irradiation in Halcyon™ ring gantry linear accelerator.

Authors:  Tanweer Shahid; Sourav Mandal; Subhra Snigdha Biswal; Arundhati De; Mukti Mukherjee; Sandipan Roy Chowdhury; Anupam Chakrapani; Kirubha George; Jibak Bhattacharya; Prosenjit Soren; Tanmoy Ghosh; Biplab Sarkar; Luca Cozzi
Journal:  Radiat Oncol       Date:  2022-08-19       Impact factor: 4.309

7.  Leaf open time sinogram (LOTS): a novel approach for patient specific quality assurance of total marrow irradiation.

Authors:  Rajesh Thiyagarajan; Dayananda Shamurailatpam Sharma; Suryakant Kaushik; Mayur Sawant; K Ganapathy; N Arunai Nambi Raj; Srinivas Chilukuri; Sham C Sundar; Kartikeswar Ch Patro; Arjunan Manikandan; M P Noufal; Rangasamy Sivaraman; Jose Easow; Rakesh Jalali
Journal:  Radiat Oncol       Date:  2020-10-14       Impact factor: 3.481