Literature DB >> 30998857

Bioelectrical impedance analysis does not detect an increase in total body water following isotonic fluid consumption.

Evan L Matthews1,1, Peter A Hosick1,1.   

Abstract

PURPOSE: To determine if single-frequency foot-to-foot bioelectrical impedance analysis (BIA) can detect acute changes in total body water (TBW) following consumption of isotonic saline. All participants ate a sodium-free meal at 4 h prior to the data collection visit and had euhydration confirmed using urine specific gravity at the beginning of the experimental visit. Subjects drank 466 mL of isotonic saline (Na+ 140 mmol·L-1) following baseline measures. Blood sampling and BIA were performed at baseline and every 30 min for 3 h after saline consumption. Ten healthy participants completed this study. Plasma volume (5%Δ, p < 0.001) and serum sodium concentration (1%Δ, p < 0.001) increased by 60 min and 90 min, respectively. Body mass (p < 0.001) displayed a biphasic response increasing to a peak at 30 min (+0.38Δkg) and then decreasing to its minimum at 180 min (-0.35Δkg). BIA impedance (p = 0.678) was unaffected by the saline administration. BIA-derived TBW (p = 0.039) decreased from baseline starting at 150 min (0.21Δkg). Novelty Athletes and coaches wishing to achieve hyperhydration can do so through the consumption of isotonic fluid. 50 kHz foot-to-foot BIA-derived TBW is inadequate for measuring hyperhydration. Future studies should examine the physiological and performance effects of such a hyperhydration protocol.

Entities:  

Keywords:  athlete performance; body composition; composition corporelle; exercise nutrition; hydratation; hydration; nutrition sportive; nutrition à l’effort; performance des athlètes; physiologie; physiology; sports nutrition

Mesh:

Substances:

Year:  2019        PMID: 30998857     DOI: 10.1139/apnm-2019-0106

Source DB:  PubMed          Journal:  Appl Physiol Nutr Metab        ISSN: 1715-5312            Impact factor:   2.665


  6 in total

1.  Acute Water Supplementation Improved the Body Composition of Young Female Adults After Water Restriction of 12 h in Baoding, China: A Randomized Controlled Trial (RCT).

Authors:  Jianfen Zhang; Na Zhang; Songming Du; Shufang Liu; Guansheng Ma
Journal:  Front Nutr       Date:  2022-06-20

2.  Bioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients.

Authors:  Se-Hee Yoon; Seul-Gi Kim; In-Beom Jeong; Won-Min Hwang; Sung-Ro Yun
Journal:  Med Sci Monit       Date:  2019-11-09

3.  Bioelectrical Impedance Changes of the Trunk are Opposite the Limbs Following Acute Hydration Change.

Authors:  Dale R Wagner
Journal:  J Electr Bioimpedance       Date:  2022-06-25

4.  Classification Accuracy of Body Mass Index for Excessive Body Fatness in Kuwaiti Adolescent Girls and Young Adult Women.

Authors:  Hanouf Al Hammadi; John J Reilly
Journal:  Diabetes Metab Syndr Obes       Date:  2020-04-05       Impact factor: 3.168

5.  Evaluating of altered hydration status on effectiveness of body composition analysis using bioelectric impedance analysis.

Authors:  Seda Ugras
Journal:  Libyan J Med       Date:  2020-12       Impact factor: 1.657

6.  Utility of an Isotonic Beverage on Hydration Status and Cardiovascular Alterations.

Authors:  Emily E Bechke; Mitchell E Zaplatosch; Ji-Yeon Choi; William M Adams
Journal:  Nutrients       Date:  2022-03-18       Impact factor: 5.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.