| Literature DB >> 30996511 |
Samuel L Manzello1, Sayaka Suzuki2, Tomohiro Naruse3.
Abstract
Large outdoor fires present a risk to the built environment. Examples often in the international media reports are wildfires that spread into communities, referred to as Wildland-Urban Interface (WUI) fires. Other examples are large urban fires including those that have occurred after earthquakes. Firebrands are a key mechanism on how rapidly fires spread in urban fires and WUI fires. An experimental protocol has been developed to ignite full-scale roofing assemblies and quantify the degree of firebrand production during the combustion process. As wind is an important factor in firebrand generation, the experiments were conducted under a range of wind speeds at the Building Research Institute's (BRI) Fire Research Wind Tunnel Facility (FRWTF). A further unique aspect of this work is the experimental results are compared to firebrand size and mass distributions collected from an actual large-scale urban fire in Japan. Results of these experiments demonstrate that when only oriented strand board (OSB) is applied as sheathing, a significant number of firebrands collected from roofing assemblies were less than 1 g and 10 cm2. It was also observed that experiments on individual building component firebrand generation provided useful insights into actual urban fire firebrand generation.Entities:
Keywords: Firebrands; Generation; Large Outdoor Fires; Urban Fires; WUI Fires
Year: 2018 PMID: 30996511 PMCID: PMC6463531 DOI: 10.1002/fam.2661
Source DB: PubMed Journal: Fire Mater ISSN: 0308-0501 Impact factor: 2.407