Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation.

Biplab Sarkar1, Anusheel Munshi2, Tharmarnadar Ganesh2, Arjunan Manikandan3, Bidhu K Mohanti2.   

Abstract

Since 2011 when it was first described, the volumetric-modulated arc therapy (VMAT) technique for craniospinal irradiation (CSI) has always seen the use of large arc lengths for the spine fields ranging from 200° to 360°. This study was aimed to do a dosimetric comparison between the large and shorter spinal arc for CSI. For a cohort of 10 patients, 2 VMAT CSI plans were created for each patient, one using the conventional full 360° arc (VMAT_FA) for the spine and the other using 100° posterior arc (VMAT_PA) for 23.4 Gy and 35 Gy prescriptions. In both the plans, 360° arc fields were employed for treating cranial volume. Spillage dose (DBody-PTV) to Body-PTV (DBody-PTV: dose to body excluding planning target volume) was compared with VMAT_FA and VMAT_PA plans. In addition to these VMAT plans, a 3-dimensional conformal radiotherapy plan was also created for all these patients to compare the DBody-PTV and target volume related dose constraints. Mean D95% difference between the two VMAT plans did not exceed 1.3% for cranial and spinal targets for both prescription levels. The conformity index (CI) was averaged over both prescription doses. Average CI shows a similar value for VMAT_FA (0.84 ± 0.04) and VMAT_PA (0.82 ± 0.05) plans. D95%, V110% and CI did not exhibit a statistically significant difference between partial and full-arc VMAT plans. However, the VMAT_PA plan exhibited a lower DBody-PTV compared to VMAT_FA plans (0.007 ≤ p < 0.05) in the 1 to 5 Gy range. Nevertheless, partial arc plans could not offer a statistically significant dose reduction for delineated organs compared to full arc plans, except for bilateral kidneys.
Copyright © 2019 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3DCRT; CSI; Conformity; Medulloblastoma; PNET; Short arc; VMAT

Mesh:

Year:  2019        PMID: 30995966     DOI: 10.1016/j.meddos.2019.03.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Preclinical validation and treatment of volumetric modulated arc therapy based total bone marrow irradiation in Halcyon™ ring gantry linear accelerator.

Authors:  Tanweer Shahid; Sourav Mandal; Subhra Snigdha Biswal; Arundhati De; Mukti Mukherjee; Sandipan Roy Chowdhury; Anupam Chakrapani; Kirubha George; Jibak Bhattacharya; Prosenjit Soren; Tanmoy Ghosh; Biplab Sarkar; Luca Cozzi
Journal:  Radiat Oncol       Date:  2022-08-19       Impact factor: 4.309

2.  Modified volumetric modulated arc therapy technique with reduced planning and treatment time for craniospinal irradiation utilising two isocentres.

Authors:  Minh Nguyen; Thu Dang; Liz Deegan; Kelsie Henry; Scott Jones; Andrew Pullar; Robyn Cheuk; Adrian Gibbs; Lucy Sim; Catriona Hargrave
Journal:  J Med Radiat Sci       Date:  2022-04-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.