Literature DB >> 30987905

Comparison of Clinical Outcomes and Computed Tomography Analysis for Tunnel Diameter After Arthroscopic Bankart Repair With the All-Suture Anchor and the Biodegradable Suture Anchor.

Jae-Hoo Lee1, In Park1, Hwan-Sub Hyun1, Sang-Woo Kim1, Sang-Jin Shin2.   

Abstract

PURPOSE: To compare the clinical outcomes and radiological findings at the anchor site after arthroscopic Bankart repair with all-suture anchors and biodegradable suture anchors in patients with recurrent anterior shoulder dislocation.
METHODS: The patients who underwent arthroscopic Bankart repair were divided into 2 groups depending on the type of the suture anchor used in different periods. Power analysis was designed based on the postoperative Rowe score. Clinical outcomes, including the Rowe score, American Shoulder and Elbow Surgeons score, subjective instability, and redislocation rates were evaluated. In all patients enrolled, the tunnel diameter of the anchor was assessed with computed tomography arthrogram at 1 year postoperatively. The Institutional Review Board of Ewha Womans University approved this study (no. EUMC 2017-05-058).
RESULTS: A total of 67 patients were enrolled: 33 underwent surgery with a 1.3-mm (single-loaded) or 1.8-mm (double-loaded) all-suture anchor (group A), and 34 underwent surgery with a 3.0-mm biodegradable anchor (10.8 mm in length, 30% 1,2,3-trichloropropane/70% poly-lactide-co-glycolic acid) (group B). There were no significant differences in clinical outcomes between groups A and B in the American Shoulder and Elbow Surgeons score (preoperatively, 51.2 ± 13.7 vs 47.7 ± 12.2; 2 years postoperatively, 88.5 ± 12.3 vs 89.7 ± 10.9; P = .667) and Rowe score (preoperatively, 41.4 ± 10.5 vs 41.3 ± 9.4; 2 years postoperatively, 87.9 ± 14.9 vs 88.5 ± 14.6; P = .857). Postoperative redislocation (6.1% vs 5.9%, P = .682) and subjective instability rate (12.2% vs 17.7%, P = .386) of both groups showed no significant difference. Average tunnel diameter increment was significantly greater with the 1.8-mm all-suture anchor (2.8 ± 0.9 mm) than the 1.3-mm all-suture anchor (1.2 ± 0.8 mm) and 3.0-mm biodegradable anchor (0.8 ± 1.2 mm) (P < .001).
CONCLUSIONS: Arthroscopic Bankart repair with the all-suture anchor showed comparable clinical outcomes and postoperative stability as the conventional biodegradable suture anchor at 2 years after surgery. Tunnel diameter increment of the all-suture anchor was significantly greater than that of the biodegradable suture anchor at the 1-year computed tomography analysis. Although tunnel diameter increment was greater with the all-suture anchor, it did not influence the clinical outcomes. LEVEL OF EVIDENCE: Level III, retrospective comparative study.
Copyright © 2019 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30987905     DOI: 10.1016/j.arthro.2018.12.011

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  8 in total

1.  Arthroscopic remplissage with all-suture anchors causes cystic lesions in the humerus: a volumetric CT study of 55 anchors.

Authors:  Miguel Angel Ruiz Ibán; Rosa Vega Rodriguez; Raquel Ruiz Díaz; Roque Pérez Expósito; Irene Zarcos Paredes; Jorge Diaz Heredia
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-10-08       Impact factor: 4.342

2.  Surgical delay for traumatic recurrent shoulder dislocations leads to inferior functional outcomes.

Authors:  Ravi Gupta; Shrenuj Goel; Anil Kapoor; Ashwani Soni; Gladson David Masih; Ravi Jethwa
Journal:  J Clin Orthop Trauma       Date:  2022-04-08

3.  Comparison between all-suture and biocomposite anchors in the arthroscopic treatment of traumatic anterior shoulder instability: A retrospective cohort study.

Authors:  Ioannis Pantekidis; Michael-Alexander Malahias; Stefania Kokkineli; Emmanouil Brilakis; Emmanouil Antonogiannakis
Journal:  J Orthop       Date:  2021-03-27

4.  Peri-anchor cyst formation after arthroscopic bankart repair: comparison between biocomposite suture anchor and all-suture anchor.

Authors:  Seokhwan Jin; Yong-Min Chun
Journal:  Clin Shoulder Elb       Date:  2020-11-27

5.  All-suture anchors versus metal suture anchors in the arthroscopic treatment of traumatic anterior shoulder instability: A comparison of mid-term outcomes.

Authors:  Enes Uluyardımcı; Durmuş Ali Öçgüder; İbrahim Bozkurt; Selçuk Korkmazer; Mahmut Uğurlu
Journal:  Jt Dis Relat Surg       Date:  2021-01-06

6.  No Difference Between Anchorless and Traditional Suture Anchors in Arthroscopic Bankart Repair: A Clinical Comparison.

Authors:  Lucas Haase; Kelsey Wise; Brandon Kelly; John Harris; Jeffrey Macalena
Journal:  Cureus       Date:  2022-07-18

7.  Knotless PEEK and double-loaded biodegradable suture anchors ensure comparable clinical outcomes in the arthroscopic treatment of traumatic anterior shoulder instability: a prospective randomized study.

Authors:  Maristella F Saccomanno; Simone Cerciello; Marco Adriani; Marcello Motta; Almerico Megaro; Stefano Galli; Alessandra Scaini; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-04-18       Impact factor: 4.114

8.  Double-loaded suture anchors in the treatment of anteroinferior glenohumeral instability.

Authors:  Peter N Chalmers; Bradley Hillyard; Jun Kawakami; Garrett Christensen; Dillon O'Neill; Victoria Childress; Robert Z Tashjian
Journal:  JSES Int       Date:  2020-05-30
  8 in total