Literature DB >> 30984980

Functional Optical Zone and Centration Following SMILE and LASIK: A Prospective, Randomized, Contralateral Eye Study.

Iben B Damgaard, Marcus Ang, Ashraf M Mahmoud, Mohamed Farook, Cynthia J Roberts, Jodhbir S Mehta.   

Abstract

PURPOSE: To compare centration and functional optical zone (FOZ) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (LASIK).
METHODS: In this prospective, randomized, single-masked, paired-eyed, clinical trial, 70 patients received SMILE in one eye and LASIK in the other eye for myopia and myopic astigmatism. FOZ was calculated using custom software on 3-month postoperative refractive power maps (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany). Programmed treatment area was defined as the total area of the programmed OZ plus the transition zone. Centration was evaluated by the linear distance between FOZ centroid and the pupil center and the corneal apex.
RESULTS: The average preoperative spherical equivalent (-5.38 ± 1.65 vs -5.45 ± 1.61 diopters [D]), postoperative spherical equivalent (0.05 ± 0.39 vs 0.06 ± 0.39 D), uncorrected distance visual acuity (0.01 ± 0.13 vs 0.00 ± 0.08 logMAR), and corrected distance visual acuity (-0.07 ± 0.10 vs -0.07 ± 0.10 logMAR) were comparable in SMILE- and LASIK-treated eyes of the 60 patients with complete datasets (P > .419). Postoperative increase in spherical aberration was lower in SMILE than in LASIK (0.08 ± 0.16 vs 0.17 ± 0.18 µm, P = .002). The FOZ area was significantly larger in SMILE than in LASIK (30.25 ± 3.60 vs 29.21 ± 3.72 mm2), despite the smaller programmed OZ diameter (6.48 ± 0.08 vs 6.52 ± 0.11 mm) and smaller programmed treatment area (33.87 ± 0.81 vs 46.30 ± 2.61 mm2, P < .037). Pupil centration (0.43 ± 0.21 vs 0.41 ± 0.22 mm) and apex centration (0.48 ± 0.24 vs 0.48 ± 0.22 mm) were comparable between SMILE and LASIK (P > .694).
CONCLUSIONS: SMILE created a larger FOZ than LASIK, despite the smaller programmed OZ. This may be due to a difference in the biomechanical response between the two procedures. Visual outcome and centration were comparable between SMILE and LASIK. [J Refract Surg. 2019;35(4):230-237.]. Copyright 2019, SLACK Incorporated.

Entities:  

Mesh:

Year:  2019        PMID: 30984980     DOI: 10.3928/1081597X-20190313-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  9 in total

Review 1.  Refractive surgery beyond 2020.

Authors:  Marcus Ang; Damien Gatinel; Dan Z Reinstein; Erik Mertens; Jorge L Alió Del Barrio; Jorge L Alió
Journal:  Eye (Lond)       Date:  2020-07-24       Impact factor: 3.775

Review 2.  Review on Centration, Astigmatic Axis Alignment, Pupil Size and Optical Zone in SMILE.

Authors:  Quan Liu; Xiaonan Yang; Limian Lin; Manli Liu; Haiqin Lin; Fang Liu; Yi Xie; Dennis S C Lam
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Sep-Oct

3.  Clinical Outcomes of Small Incision Lenticule Extraction in Myopia: Study of Vector Parameters and Corneal Aberrations.

Authors:  Jay Jiyong Kwak; Ikhyun Jun; Eung Kweon Kim; Kyoung Yul Seo; Tae Im Kim
Journal:  Korean J Ophthalmol       Date:  2020-02

4.  Prospective, Randomized, Contralateral Eye Comparison of Functional Optical Zone, and Visual Quality After SMILE and FS-LASIK for High Myopia.

Authors:  Shengyu He; Yiqi Luo; Pei Chen; Yiming Ye; Hua Zheng; Min Lan; Jing Zhuang; Keming Yu
Journal:  Transl Vis Sci Technol       Date:  2022-02-01       Impact factor: 3.283

5.  Comparison of Corneal Optical Quality After SMILE, Wavefront-Optimized LASIK and Topography-Guided LASIK for Myopia and Myopic Astigmatism.

Authors:  Yu Zhang; Xiaoxiao Sun; Yueguo Chen
Journal:  Front Med (Lausanne)       Date:  2022-04-05

6.  Corneal Lenticule Creation Using a New Solid-State Femtosecond Laser Measured by Spectral Domain OCT in a Porcine Eye Model.

Authors:  Christoph Lwowski; Anna Voigt; Karel Van Keer; Thomas Kohnen
Journal:  Transl Vis Sci Technol       Date:  2022-06-01       Impact factor: 3.048

7.  Twelve-year global publications on small incision lenticule extraction: A bibliometric analysis.

Authors:  Tian Han; Liang Zhao; Yang Shen; Zhi Chen; Dong Yang; Jiaoyan Zhang; Walter Sekundo; Rupal Shah; Jinhui Tian; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-09-08

Review 8.  Advances in refractive corneal lenticule extraction.

Authors:  Matthias Fuest; Jodhbir S Mehta
Journal:  Taiwan J Ophthalmol       Date:  2021-04-24

9.  Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study.

Authors:  Yewei Yin; Ying Lu; Aiqun Xiang; Yanyan Fu; Yang Zhao; Yuanjun Li; Tu Hu; Kaixuan Du; Shengfa Hu; Qiuman Fu; Xiaoying Wu; Dan Wen
Journal:  BMC Ophthalmol       Date:  2021-08-02       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.