Literature DB >> 30984978

Standard Clinical Outcomes With a New Low Addition Trifocal Intraocular Lens.

Joaquín Fernández, Manuel Rodríguez-Vallejo, Javier Martínez, Ana Tauste, David P Piñero.   

Abstract

PURPOSE: To evaluate the standard clinical outcomes, defocus curves, and satisfaction obtained with a new diffractive low addition trifocal intraocular lens (IOL).
METHODS: Thirty patients who were implanted with the Versario Multifocal 3F IOL (Valeant Med Sp.zo.o., Warsaw, Poland) were recruited for a prospective observational study at Qvision, Vithas Virgen del Mar Hospital, Almería, Spain. Variables for reporting standard outcomes were collected at the 1-month visit for monocular vision and the 3-month visit for binocular vision, including best spectacle refraction and corrected and uncorrected visual acuities at far, intermediate (67 cm), and near (40 cm) distances. In addition, monocular and binocular visual acuity defocus curves were measured and questionnaires for grading subjective visual quality, satisfaction, and visual function were supplied at the end of the follow-up.
RESULTS: Monocular corrected distance visual acuity decreased progressively from far (-0.05 logMAR) to near (0.25 logMAR) and improved approximately -0.1 logMAR along the defocus curve in binocular vision. The mean residual spherical equivalent (SE) was 0.15 ± 0.47 diopters (D), with 79% of eyes within ±0.50 D and 97% within ±1.00 D with the SRK/T formula. All of the visual function tasks improved after surgery, especially driving at night, which increased from 58 to 79 (P < .05). Of 27 patients, 84.4% were satisfied or very satisfied with their general vision.
CONCLUSIONS: This new lens was similar in terms of visual performance and satisfaction to other trifocal IOLs. It can be classified as a trifocal extended depth of focus IOL because of the performance between extended depth of focus IOLs and medium-high addition trifocal IOLs. [J Refract Surg. 2019;35(4):214-221.]. Copyright 2019, SLACK Incorporated.

Entities:  

Mesh:

Year:  2019        PMID: 30984978     DOI: 10.3928/1081597X-20190306-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Patient selection to optimize near vision performance with a low-addition trifocal lens.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Optom       Date:  2019-11-01

2.  Visual performance, safety and patient satisfaction after bilateral implantation of a trifocal intraocular lens in presbyopic patients without cataract.

Authors:  Joaquín Fernández; José F Alfonso Sánchez; Mark Nieradzik; Beatriz Valcárcel; Noemí Burguera; Alexander Kapp
Journal:  BMC Ophthalmol       Date:  2022-08-10       Impact factor: 2.086

3.  Through-Focus Energy Efficiency and Longitudinal Chromatic Aberration of Three Presbyopia-Correcting Intraocular Lenses.

Authors:  María S Millán; Fidel Vega
Journal:  Transl Vis Sci Technol       Date:  2020-11-09       Impact factor: 3.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.