Literature DB >> 30981083

Effect of high heel gait on hip and knee-ankle-foot rollover characteristics while walking over inclined surfaces - A pilot study.

Ekant Mishra1, Shreeshan Jena1, Chittaranjan Bhoi1, Thirugnanam Arunachalam2, Subrata Kumar Panda3.   

Abstract

Given the massive number of individuals wearing high-heeled shoes, understanding the gait biomechanics associated with their use could provide insight into clinically preventable abnormalities. The effects of inclined surfaces on the high-heeled gait have been investigated in the present pilot study, as most walking surfaces encountered in routine life are rarely perfectly level grounded. The rollover shapes of the high-heel shod gait are calculated to obtain the desired results. An adjustable inclined walkway setup was fabricated and comprising fixed slots permitting discrete and variable angle of inclinations (≤30°). The gait trials were recorded for the heel shod walking of ten healthy female volunteers using the three-dimensional motion analysis system by varying the inclination of the fabricated walkway. From the calculated rollover shapes, the necessary radii of the hip and the knee-ankle- foot rollover shapes were obtained and a repeated measures analysis of variance was carried out to establish the existence of correlation between the angle of inclination and rollover radii. The results of the present pilot study show that for high heel-shod walking there exist variable radii of curvature for early and late stance phases and that the same may vary depending upon the inclination. The same information can be used to modify the design of high-heel shoes to improve the stability while retaining their aesthetics.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Keywords:  Analysis of variance; Gait analysis; Inclined walkway; Radii of curvature

Mesh:

Year:  2019        PMID: 30981083     DOI: 10.1016/j.foot.2019.03.004

Source DB:  PubMed          Journal:  Foot (Edinb)        ISSN: 0958-2592


  2 in total

1.  A robust technique for optimal fitting of roll-over shapes of human locomotor systems.

Authors:  Ganesh M Bapat; Sara A Myers
Journal:  Med Eng Phys       Date:  2022-01-14       Impact factor: 2.242

2.  Closing the Wearable Gap-Part II: Sensor Orientation and Placement for Foot and Ankle Joint Kinematic Measurements.

Authors:  David Saucier; Tony Luczak; Phuoc Nguyen; Samaneh Davarzani; Preston Peranich; John E Ball; Reuben F Burch; Brian K Smith; Harish Chander; Adam Knight; R K Prabhu
Journal:  Sensors (Basel)       Date:  2019-08-10       Impact factor: 3.576