Literature DB >> 30979530

Atrioventricular node reentrant tachycardia: Remote magnetic navigation ablation versus manual ablation - impact on operator fluoroscopy time.

Leonor Parreira1, Rita Marinheiro2, Pedro Carmo3, Diogo Cavaco3, Katya Reis-Santos3, Pedro Amador2, Tiago Teixeira3, Ana Sofia Soares3, Francisco Costa3, Pedro Adragao3.   

Abstract

INTRODUCTION AND AIMS: Remote magnetic navigation systems have demonstrated benefits in the ablation of difficult substrates. Their role in the ablation of atrioventricular nodal reentrant tachycardia (AVNRT), however, has only been studied in small patient series. The aim of this study was to compare the results of AVNRT ablation using magnetic navigation, in a center where every procedure is performed with this system, with manual ablation.
METHODS: We selected 139 consecutive patients undergoing AVNRT ablation with magnetic navigation by a single operator between January 2009 and June 2016 and compared them to a group of 101 consecutive patients undergoing manual ablation in the same period by the same operator in another hospital. The methodology was the same in both groups. Success rates, complications, procedure time, radiofrequency time, total and operator fluoroscopy time, and recurrence rates were compared.
RESULTS: There were no differences in success and complication rates. Procedure and total fluoroscopy times were not significantly different, but operator fluoroscopy time was significantly shorter with the magnetic navigation system (2.4±1.5 min vs. 7.2±4 min; p<0.001). The recurrence rate was higher in the manual group, although without statistical significance.
CONCLUSIONS: The ablation of AVNRT with magnetic navigation is feasible using the same methodology as for manual ablation. Success and complication rates were similar. Operator fluoroscopy time was significantly less with the magnetic navigation system.
Copyright © 2019 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Ablação por cateter; Atrioventricular nodal reentrant tachycardia; Catheter ablation; Magnetic navigation system; Navegação magnética; Supraventricular tachycardias; TRNAV; Taquicardia supraventricular

Mesh:

Year:  2019        PMID: 30979530     DOI: 10.1016/j.repc.2018.07.006

Source DB:  PubMed          Journal:  Rev Port Cardiol (Engl Ed)        ISSN: 2174-2049


  1 in total

1.  Remote magnetic navigation shows superior long-term outcomes in pediatric atrioventricular (nodal) tachycardia ablation compared to manual radiofrequency and cryoablation.

Authors:  Anna M E Noten; Janneke A E Kammeraad; Nawin L Ramdat Misier; Sip Wijchers; Ingrid M van Beynum; Michiel Dalinghaus; Thomas B Krasemann; Sing-Chien Yap; Natasja M S de Groot; Tamas Szili-Torok
Journal:  Int J Cardiol Heart Vasc       Date:  2021-10-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.