| Literature DB >> 30979307 |
T Tibet Akbas1, Oguz C Celik2, Cem Yalcin3, Alper Ilki4.
Abstract
Composite reinforcing bars (rebars) that are used in concrete members with high performance (strength and durability) properties could have beneficial effects on the behavior of these members. This is especially vital when a building is constructed in an aggressive environment, for instance a corrosive environment. Although tension capacity/weight (or volume) ratios in composite rebars (carbon fiber reinforced polymer (CFRP), glass fiber reinforced polymer (GFRP), etc.) are very high when compared to steel rebars, major weaknesses in concrete members reinforced with these composite rebars may be the potential consequences of relatively poor bonding capacity. This may even be more crucial when the member is subjected to cyclic loading. Although monotonic bond tests are available in the literature, only limited experimental studies exist on bond characteristics under cyclic loading conditions. In order to fill this gap and propose preliminary design recommendations, 10 specimens of 10-mm-diameter ribbed CFRP rebars embedded in specially designed high strength concrete (f'c = 70 MPa) blocks were subjected to monotonic and cyclic pullout tests. The experimental results showed that cyclically loaded CFRP rebars had less bond strength than those companion specimens loaded monotonically.Entities:
Keywords: CFRP; bond strength; cyclic; high strength concrete; pullout
Year: 2016 PMID: 30979307 PMCID: PMC6432228 DOI: 10.3390/polym8060211
Source DB: PubMed Journal: Polymers (Basel) ISSN: 2073-4360 Impact factor: 4.329
Figure 1Mixture design.
Mixture proportions used for the test series.
| Mixture | Water/Cement | Water (kg/m3) | Cement (kg/m3) | Coarse Aggregate, 12–25 mm (kg/m3) | Coarse Aggregate, 6–12 mm (kg/m3) | Fine Aggregate, 0–6 mm (kg/m3) | Silica Fume (kg/m3) | Plasticizer (kg/m3) |
|---|---|---|---|---|---|---|---|---|
| HSC | 0.30 | 135 | 300 | 522 | 468 | 787 | 150 | 5.85 |
Figure 2Rebar surface.
Figure 3Rebar rupture test. (a) Test setup; (b) End of test; (c) Location of rupture.
Mechanical properties of CFRP rebars according to catalogue.
| Values in the longitudinal direction of the fibers [ | ||
| Mean value | 148,000 N/mm2 | |
| Minimum value | >140,000 N/mm2 | |
| Values in longitudinal direction of fibers [ | ||
| Mean value | 3,100 N/mm2 | |
| Minimum value | >2,800 N/mm2 | |
| 5% Fractile Value | 2,900 N/mm2 | |
| 95% Fractile Value | 3,250 N/mm2 | |
| Values in longitudinal direction of fibers [ | ||
| Minimum value | >1.70% | |
| Minimum tensile force | >110 kN | |
Figure 4Test Setup. (a) Loading frame; (b) Concrete block dimensions; (c) LVDT location.
Figure 5Expected failure modes. (a) Rebar rupture side view; (b) Pullout side view; (c) Splitting failure (shear type) side and top views; (d) Splitting failure (V-notch type) top views.
Figure 6Failure mechanisms. (a) Failure of surface; (b) Concrete crushing.
Figure 7Transfer of force through bond.
Test results
| Specimen 1 | Loading type | ACI | Test | Failure Mode | |||
|---|---|---|---|---|---|---|---|
| S21-25D-T-U | 250 | C 5 | 6.02 | 47.31 | 8.93 | 70.1 | Splitting |
| S22-25D-M-U | 250 | M 6 | 11.00 | 86.4 | Splitting Rupture | ||
| S23-20D-M-U | 200 | M | 6.71 | 42.18 | 12.80 | 80.4 | Splitting |
| S24-20D-T-U | 200 | C | 11.52 | 72.4 | Pull-out | ||
| S25-15D-T-U | 150 | C | 7.86 | 37.04 | 13.84 | 65.2 | Pull-out |
| S26-15D-M-U | 150 | M | 17.74 | 83.6 | Splitting | ||
| S27-10D-T-U | 100 | C | 10.15 | 31.90 | 11.01 | 34.6 | Pull-out |
| S28-10D-M-U | 100 | M | 12.32 | 38.7 | Pull-out | ||
| S29-5D-M-U | 50 | M | 17.04 | 26.77 | 18.02 | 28.3 | Pull-out |
| S30-5D-T-U | 50 | C | 10.31 | 16.2 | Pull-out | ||
1 ribbed 10 mm rebar, 2 embedment length, 3 average bond stress, 4 bond strength, 5 cyclic loading, 6 monotonic loading.
Figure 8Experimental bond stress versus slip curves. (a) 25 d; (b) 20 d; (c) 15 d; (d) 10 d; (e) 5 d.
Figure 9(a) Splitting failure; (b) Section of bonded and unbonded regions.
Figure 10(a) Pullout failure; (b) No damage observed on concrete surface.