Chao Zou1, Chuanli Cheng1,2, Yangzi Qiao1, Qian Wan1,2, Changjun Tie1, Min Pan3, Dong Liang1,4, Hairong Zheng1,4, Xin Liu1,4. 1. Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. 2. Shenzhen College of Advanced Technology, University of Chinese Academy of Sciences, Shenzhen 518055, China. 3. Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen 518049, China. 4. Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine, Chongqing 400016, China.
Abstract
BACKGROUND: Multi-echo gradient echo (GRE) sequence with bipolar readout gradients can reduce achievable echo spacing and thus have higher acquisition efficiency compared to unipolar readout gradients for fat fraction (FF) quantification. However, the eddy current induced phase (EC-phase) in a bipolar sequence corrupts the phase consistency between echoes and can lead to inaccurate fat quantification. METHODS: A hierarchical iterative linear-fitting algorithm (HILA) was proposed for EC-phase correction. In each iteration, image blocks were divided into sub-blocks. The EC-phase was fitted to a linear model in each sub-block. The estimated linear phase in each sub-block was then used as a starting value for the next iteration. Finally, a weighted average over all levels was calculated to obtain the final EC-phase map. Monte Carlo simulations were adopted to evaluate how the residual EC-phase would affect FF quantification accuracy. The performance of the proposed HILA method was then compared to the well-established unipolar acquisition method in phantom and in vivo experiments on 3T. RESULTS: The simulations showed that certain ΔTE values, such as ΔTE =~0.80/1.50/1.95 ms, allowed for FF estimation that were relatively robust to the residual EC-phase ranging from -2π/15 to 2π/15 for a 6-echo bipolar acquisition on 3T. The phantom study showed that the maximum mean FF error, after EC-phase correction with the proposed HILA method, was smaller than 2%, implying that HILA can approximate the high-order term of the EC-phase through step-wise linear fitting. There was no significant difference between the FFs from bipolar and unipolar acquisitions on the two MR systems in the in vivo experiments. CONCLUSIONS: The proposed HILA method provides a simple and efficient EC-phase correction method for bipolar acquisition without acquiring additional data. The appropriate choice of TEs may further reduce the effect of the residual EC-phase on accurate FF quantification with bipolar readout sequence.
BACKGROUND: Multi-echo gradient echo (GRE) sequence with bipolar readout gradients can reduce achievable echo spacing and thus have higher acquisition efficiency compared to unipolar readout gradients for fat fraction (FF) quantification. However, the eddy current induced phase (EC-phase) in a bipolar sequence corrupts the phase consistency between echoes and can lead to inaccurate fat quantification. METHODS: A hierarchical iterative linear-fitting algorithm (HILA) was proposed for EC-phase correction. In each iteration, image blocks were divided into sub-blocks. The EC-phase was fitted to a linear model in each sub-block. The estimated linear phase in each sub-block was then used as a starting value for the next iteration. Finally, a weighted average over all levels was calculated to obtain the final EC-phase map. Monte Carlo simulations were adopted to evaluate how the residual EC-phase would affect FF quantification accuracy. The performance of the proposed HILA method was then compared to the well-established unipolar acquisition method in phantom and in vivo experiments on 3T. RESULTS: The simulations showed that certain ΔTE values, such as ΔTE =~0.80/1.50/1.95 ms, allowed for FF estimation that were relatively robust to the residual EC-phase ranging from -2π/15 to 2π/15 for a 6-echo bipolar acquisition on 3T. The phantom study showed that the maximum mean FF error, after EC-phase correction with the proposed HILA method, was smaller than 2%, implying that HILA can approximate the high-order term of the EC-phase through step-wise linear fitting. There was no significant difference between the FFs from bipolar and unipolar acquisitions on the two MR systems in the in vivo experiments. CONCLUSIONS: The proposed HILA method provides a simple and efficient EC-phase correction method for bipolar acquisition without acquiring additional data. The appropriate choice of TEs may further reduce the effect of the residual EC-phase on accurate FF quantification with bipolar readout sequence.
Authors: Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Wenmiao Lu; Scott B Reeder; R Scott Hinks; Jean H Brittain Journal: J Magn Reson Imaging Date: 2010-05 Impact factor: 4.813
Authors: Sina Meisamy; Catherine D G Hines; Gavin Hamilton; Claude B Sirlin; Charles A McKenzie; Huanzhou Yu; Jean H Brittain; Scott B Reeder Journal: Radiology Date: 2011-01-19 Impact factor: 11.105
Authors: Houchun Harry Hu; Peter Börnert; Diego Hernando; Peter Kellman; Jingfei Ma; Scott Reeder; Claude Sirlin Journal: Magn Reson Med Date: 2012-06-12 Impact factor: 4.668
Authors: Wenmiao Lu; Huanzhou Yu; Ann Shimakawa; Marcus Alley; Scott B Reeder; Brian A Hargreaves Journal: Magn Reson Med Date: 2008-07 Impact factor: 4.668
Authors: Takeshi Yokoo; Mark Bydder; Gavin Hamilton; Michael S Middleton; Anthony C Gamst; Tanya Wolfson; Tarek Hassanein; Heather M Patton; Joel E Lavine; Jeffrey B Schwimmer; Claude B Sirlin Journal: Radiology Date: 2009-02-12 Impact factor: 11.105
Authors: Catherine D G Hines; Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Jean H Brittain; Scott B Reeder Journal: J Magn Reson Imaging Date: 2009-11 Impact factor: 4.813