Background: Repair of the pronator quadratus (PQ) muscle with sutures has been reported durable after volar plating of distal radius fractures (DRF). It is unclear how the muscle reacts if not repaired and if a retracted muscle correlates to worse functional outcome or complications. In this study, we use ultrasound to investigate the anatomy of the PQ muscle after volar plating with PQ repair or nonrepair and correlate the ultrasound findings with patient-reported outcome.
Methods: Participants were recruited from a clinical trial where they were randomly allocated to repair or nonrepair of the PQ muscle after volar plating of DRF. The participants and radiologist were blinded to group allocation. Ultrasound imaging of both fractured and contralateral wrists was performed 3 months after surgery. Ultrasound measurements included the difference in length of PQ muscle between the injured and uninjured side, retraction of PQ muscle, and tendon complications. The length and number of retractions were correlated to complications and Patient-Rated Wrist Evaluation (PRWE).
Results: The mean difference of the difference in length measurements was 4.4 mm in the nonrepair group and 2.7 mm in the repair group with a mean difference between groups of 1.7 mm. This was statically significant; however, there were no clinical or statistical differences in complication rate or PRWE between the two groups.
Conclusion: The PQ length was significantly shorter and the number of retractions significantly larger without repair of the PQ muscle; however, neither length nor retraction correlated significantly with complication rate or PRWE.

Entities:  

Keywords:  distal radius; fracture; outcome; pronator quadratus; ultra sound

Mesh:

Year:  2019        PMID: 30971133      PMCID: PMC7818026          DOI: 10.1177/1558944719840737

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  28 in total

1.  Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study.

Authors:  Carrie R Swigart; Mary A Badon; Victoria L Bruegel; Seth D Dodds
Journal:  J Hand Surg Am       Date:  2012-07-31       Impact factor: 2.230

2.  Sonographic assessment of orthopedic hardware impingement on soft tissues of the limbs.

Authors:  R Guillin; S Bianchi
Journal:  J Ultrasound       Date:  2012-01-23

Review 3.  Musculoskeletal sonography of the postoperative orthopedic patient.

Authors:  Jon A Jacobson; Matthew J Lax
Journal:  Semin Musculoskelet Radiol       Date:  2002-03       Impact factor: 1.777

4.  Epidemiology of extremity fractures in the Netherlands.

Authors:  M S H Beerekamp; R J O de Muinck Keizer; N W L Schep; D T Ubbink; M J M Panneman; J C Goslings
Journal:  Injury       Date:  2017-04-24       Impact factor: 2.586

5.  A comparison of dominant and non-dominant hand strengths.

Authors:  C A Armstrong; J A Oldham
Journal:  J Hand Surg Br       Date:  1999-08

Review 6.  Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.

Authors:  Harman Chaudhry; Ydo V Kleinlugtenbelt; Raman Mundi; Bill Ristevski; J C Goslings; Mohit Bhandari
Journal:  Clin Orthop Relat Res       Date:  2015-05-16       Impact factor: 4.176

7.  Patient rating of wrist pain and disability: a reliable and valid measurement tool.

Authors:  J C MacDermid; T Turgeon; R S Richards; M Beadle; J H Roth
Journal:  J Orthop Trauma       Date:  1998 Nov-Dec       Impact factor: 2.512

8.  Assessment of Pronator Quadratus Repair Integrity Using Dynamic Ultrasonography Following Volar Plate Fixation for Distal Radius Fractures.

Authors:  Richard M Hinds; Nicole Montero-Lopez; Kenneth Brock; Ronald Adler; Anthony Sapienza; John T Capo; Nader Paksima
Journal:  Hand (N Y)       Date:  2018-07-13

9.  Sonographic appearance of the pronator quadratus muscle in healthy volunteers.

Authors:  Junko Sato; Yoshinori Ishii; Hideo Noguchi; Mitsuhiro Takeda; Shin-ichi Toyabe
Journal:  J Ultrasound Med       Date:  2014-01       Impact factor: 2.153

10.  Anatomic Characteristics of Pronator Quadratus Muscle: A Cadaver Study.

Authors:  Phil Woo Choung; Min Young Kim; Hyung Soon Im; Ki Hoon Kim; Im Joo Rhyu; Byung Kyu Park; Dong Hwee Kim
Journal:  Ann Rehabil Med       Date:  2016-06-29
View more
  1 in total

1.  Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study.

Authors:  Xiaoxia Huang; Qiyu Jia; Huaqiang Li; Erxat Kerem; Cong Peng; Weiqi Kong; Maimaitiaili Tusunniyazi; Yimurang Hamiti; Dongwei Feng; Yan Zhao
Journal:  BMC Musculoskelet Disord       Date:  2022-06-30       Impact factor: 2.562

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.