Anterior chamber aqueous flare is not a predictor for surgical closure of full-thickness idiopathic macular holes.

Friederike Schaub1, Philip Enders1, Paula Scholz1, Philipp S Müther1, Sascha Fauser1,2, Bernd Kirchhof1.   

Abstract

PURPOSE: To investigate the predictive value of preoperative anterior chamber aqueous flare levels measured by laser flare photometry for surgical success of idiopathic macular holes in addition to preoperative anatomic characteristics.
METHODS: Records of 105 consecutive eyes with full-thickness idiopathic macular holes which underwent pars plana vitrectomy with internal limiting membrane peeling and sulfur hexafluoride 20% (SF620%) endotamponade were reviewed retrospectively. All patients underwent preoperative measurements of anterior chamber aqueous flare and anatomical idiopathic macular hole characteristics evaluated by optical coherence tomography: macular hole inner opening diameter, macular hole minimum linear diameter, macular hole base diameter, and macular hole height. Best-corrected visual acuity results were recorded pre- and postoperatively.
RESULTS: In 17 (16.2%) of 105 eyes primary closure of idiopathic macular hole failed, whereas in 88 eyes (83.8%) closure was achieved. Between both groups, preoperative macular hole minimum linear diameter (p = 0.001) and macular hole inner opening diameter (p = 0.006) were statistically different. Failure rates were significantly lower in eyes with macular hole minimum linear diameter < 400 µm (7.4% vs 32.4%; p = 0.013) and preoperative macular hole minimum linear diameter showed moderate correlation with pre- and postoperative best-corrected visual acuity results (r = 0.512; p < 0.001; r = 0.612; p < 0.001). Mean anterior chamber aqueous flare of 11.5 ± 9.9 pc/ms in eyes with anatomical closure and 11.8 ± 6.4 pc/ms in unclosed cases was comparable (p = 0.28) and did not correlate with anatomical or functional results.
CONCLUSION: Eyes with idiopathic macular hole ⩾ 400 µm in size have a significantly higher failure rate following standardized pars plana vitrectomy with internal limiting membrane peeling and SF620% endotamponade. Preoperative macular hole minimum linear diameter and macular hole inner opening diameter seem to be associated with surgical outcome in idiopathic macular hole, whereas anterior chamber aqueous flare level does not provide additional predictive value.

Entities:  

Keywords:  Anterior chamber aqueous flare; complication; idiopathic macular hole; internal limiting membrane; visual acuity; vitrectomy

Mesh:

Substances:

Year:  2019        PMID: 30968716     DOI: 10.1177/1120672119843283

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Incomplete fluid-air exchange technique for idiopathic macular hole surgery.

Authors:  Bo-Jie Hu; Xue-Li Du; Wen-Bo Li; Yu-Wen Chang; Xing-Dong Shi; Teng Ma; Yong Wang; Yan-Hua He; Rui Niu; Wei-Na Cui
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

2.  Comparison of Idiopathic Macular Hole Interventions Using Frequency Domain Optical Coherence Tomography and Optical Coherence Tomography Angiography.

Authors:  Miao Liu; Yu Jin; Liu Li; Fangxiu Yuan; Yueyuan Xu
Journal:  Dis Markers       Date:  2022-08-13       Impact factor: 3.464

  2 in total