| Literature DB >> 30966411 |
Abstract
This paper presents a review of recent studies on reinforced concrete (RC) structural components, such as beam-column joints (BCJs). These members are internally or externally reinforced with corrosion free shape memory alloy (SMA), fiber reinforced polymers (FRP), or a combination of the two materials. Bonded FRP sheets or near surface mounted (NSM) FRP bars are used in external strengthening cases. The use of FRP and SMA materials in RC structures can offer great potential benefits including lifetime cost saving, durability, safety, and post-earthquake serviceability for RC structures. Although FRP materials are well known for their corrosion resistance, high strength-to-weight ratios, ease of application, and constructability; SMA materials as reinforcement allow the structures to regain their original shape after the termination of the load without any permanent large residual deformation. In summary, the presented literature review provides an insight into the ongoing research on the use of these materials for retrofitting or strengthening of RC structural components and the trends for future research in this area. The cost and durability are also discussed.Entities:
Keywords: FRP bars; concrete; external FRP strengthening; fiber reinforced polymer (FRP); joints; near-surface-mounted (NSM); shape memory alloy (SMA)
Year: 2018 PMID: 30966411 PMCID: PMC6415212 DOI: 10.3390/polym10040376
Source DB: PubMed Journal: Polymers (Basel) ISSN: 2073-4360 Impact factor: 4.329
Summary of experimental work on BCJs internally reinforced with FRP.
| BCJs | [ | [ | [ | [ | [ | [ | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Beam | Column | Beam | Column | Beam | Column | Beam | Column | Beam | Column | Beam | Column | |
| Test parameters | Longitudinal and lateral reinforcement types | Concrete strength and beam and column longitudinal reinforcement | Longitudinal reinforcement and stirrups types and ratios | Longitudinal reinforcement and stirrups types, and details of beam longitudinal reinforcement | Concrete strength, and joint shear stress level | Presence of lateral beams, and joint shear stress level | ||||||
| Cross-section (mm2) | 250 × 400 | 400 × 250 | 150 × 200 | 150 × 200 | 350 × 450 | 350 × 500 | 350 × 450 | 350 × 350 | 350 × 450 | 400 × 350 | 300 × 350 | 350 × 400 |
| GFRP longitudinal reinforcement | 8#16 | 12#16 | 4#12 | 4#12 | 5#19 | 8#19 | 5#16 | 8#16 | 8#16 | 12#16 | 10#16 | 12#16 |
| GFRP transversal reinforcement (leg/mm) | 3#10 @ 80 mm | 3#10 @ 80 mm | 2#8 @ 150 mm | 2#8 @ 150 mm | 3#13 @ 100 mm | 3#13 @ 90 mm + 1 transversal #10 | 3#13 @ 100 mm | 3#13 @ 90mm | 3#12 @ 100 mm | 3#12 @ 90 mm | 3#12 @ 100 mm | 3#12 @ 90 mm |
| Tensile strength for longitudinal & transversal bars (MPa) | 600 | 580 | 590 | #13 = 590, | 751 | 1008 | 1100 | |||||
| #10 = 642 | ||||||||||||
| Concrete compressive strength (MPa) | _ | 44.15 | 30 | 32.5 | 51.3 | 42.2 | ||||||
| Load type | Cyclic loading | Constant axial load of 600 kN | Monotonic loading | Constant axial load | Cyclic loading | Constant axial load of 800 kN | Seismic loading | Constant axial service load = 15% column capacity | Cyclic loading | Constant axial service load = 15% column capacity | Cyclic loading | Constant axial service load = 15% column capacity |
| Max. lateral load capacity (kN) | 120 | 13.2 | 150 | - | 150 | 170 | ||||||
| Drift ratio (DR) at max. load lateral capacity (%) | 6 | 5 | 4 | 4 | 6 | 6 | ||||||
| Peculiarity | Using GFRP grid instead of bars and stirrups | Steel bend couplers at the joint for GFRP bars | 200 mm long beam stub | Couplers to connect bars together | Lateral beams as confinement | |||||||
| Cumulative energy dissipation (kN·m) | 60 | _ | 58 at 5% DR | 23 at 5% DR | 28 | 50 | ||||||
| Observed failure mode | Specimens were not tested up to failure | Joint shear failure | Concrete crushing at 4% DR in beam + rupture of beam GFRP bars at 5% DR | Concrete compression failure | Plastic hinge in the beam section followed by slippage of longitudinal reinforcement | Buckling of beam bars | ||||||
Summary of experimental work on BCJs externally reinforced with FRP using steel anchorages.
| BCJs | [ | [ | [ | [ | [ | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Beam | Column | Beam | Column | Beam | Column | Beam | Column | Beam | Column | |
| Type of study | Experimental study | Experimental study | Experimental study | Experimental study | Experimental study | |||||
| Number of specimens | 4 NS BCJs: 2 damaged + strengthened, 2 strengthened | 2 NS BCJs: 1 damaged + strengthened, 1 strengthened | 4BCJs non-seismic 1/2 scale: 2 control, damaged + strengthened, 2 strengthened with CFRP | 6 NS BCJs: (a) 3 anchorage deficient: 1 control + 2 strengthened, (b) 3 shear anchorage deficient: 1 control + strengthened | 8 full-scale BCJ: 2 control + 6 strengthened | |||||
| Test parameters | number of GFRP layers, joint height to be repaired, shape of sheets applied | number of GFRP layers, shape of sheets applied | CFRP placing areas | inadequate anchorage length of beam bottom bars, absence of steel ties in the joint zone, type of FRP, anchorage systems(steel plates, angles, rods), steel reinforcement ratio | steel reinforcement ratio, joint strengthening configuration, damaged and undamaged | |||||
| Cross-section (mm2) | 250 × 400 | 400 × 250 | 250 × 400 | 400 × 250 | 160 × 350 | 300 × 160 | 250 × 400 | 400 × 250 | 300 × 400 | 300 × 300 |
| Internal main reinforcement | 4 Ø 20 top + 4 Ø 20 bottom | 6 Ø 20 + 2 Ø 15 | 4 Ø 20 top + 4 Ø 20 bottom | 6 Ø 20 + 2 Ø 15 | 4 Ø 12 top + 4 Ø 12 bottom | 10 Ø 10 | (a) 2 Ø 20 top + 2 Ø 20 bottom, (b) 4 Ø 20 top + 4 Ø 20 bottom | (a) (b) 6 Ø 20 + 2 Ø 15 | 1–3 Ø 20 top + 3 Ø 20 bottom, 2–4 Ø 20 top + 4 Ø 20 bottom | 1–4 Ø 14, 2–8 Ø 14 |
| Internal shear reinforcement (leg/mm) | 2 Ø 10 @ 150 mm | 3 Ø 10 @ 200 mm | 2 Ø 10 @ 150 mm | 3 Ø 10 @ 200 mm | 2 Ø 6 @ 225 mm | 2 Ø 6 @ 140 mm | 2 Ø 10 @ 150 mm | 3 Ø 10 @ 200 mm | 2 Ø 8 @ 100 mm | 2 Ø 8 @ 100 mm |
| Reinf. yield strength (MPa) | #10: 450, #15: 408, #20: 425 | #10: 450, #15: 408, #20: 425 | 420 | #10: 450, #15: 408, #20: 425 | 540 | |||||
| FRP type | GFRP | GFRP | CFRP | (a) CFRP, (b) GFRP | CFRP | |||||
| FRP shape and configuration | bi-directional U-shaped + unidirectional X-shaped GFRP sheets | uni and bi-directional U-shaped GFRP sheets | unidirectional CFRP sheets | uni and bi-directional GFRP sheets | horizontal sheets, X-shaped, U-shaped | |||||
| FRP thickness (mm) | - | bi-directional = 0.864, unidirectional =0.353 | 1 | - | 0.22 | |||||
| Number of FRP layers | 1, 2, 3 | 2, 4, 8 | 1 | 2, 4, 8 | 1, 2 | |||||
| FRP tensile strength | - | bi-directional = 279 MPa, unidirectional = 1700 MPa | - | CFRP = 709.6 N/mm per sheet‘s width, uni-directional: 465.0 N/mm per sheet’s width | 3000 MPa | |||||
| Concrete compressive strength (MPa) | 25 | 30.6, 43.5, 39.5 avg. 37.8 | group 1: 30, group 2: 25 | - | 16 | |||||
| Load type | constant axial column load (300,600 kN) + reversing quasi-static cyclic load | constant 600 kN axial column load + reversing quasi-static cyclic load | cyclic loading by a 500 kN actuator + constant axial load on the column = 20% of column’s capacity | constant 600 kN axial column load + cyclic load | cyclic loading | |||||
| Peculiarity | column confined by GFRP sheets and anchored using steel plates and threaded steel rods | column confined by GFRP sheets and anchored using steel plates and threaded steel rods + beam GFRP sheets anchored with U-shaped steel plates | restrained with slab, 2 schemes for strengthening, 2nd scheme uses bolts and steel plates to provide mechanical anchorages | (a) CFRP sheets on columns anchored using steel plates and threaded steel rods + beam CFRP sheets anchored with U-shaped steel plates, (b)one of BCJ steel rods threaded from column towards beam and covered with epoxy mortar, tie rods welded to beam bottom bars | use of steel plates on the beam, threaded rods, L-shaped and U-shaped steel plates | |||||
| Max. lateral load capacity (kN) | 127 | damaged-strengthened: 110, undamaged-strengthened: 114.4 | 85.4 in undamaged-strengthened specimens | (a) 86, (b) 152 | push: avg. 76.2, pull: avg. 73.1 | |||||
| DR of max. capacity (%) | - | Damaged-strengthened 1.2, undamaged-strengthened 1.3 | - | (a) 1.98, (b) 2.43 | push: avg. 1.74, pull: avg. 1.73 | |||||
| Ductility increase as compared to control (%) | 60 | higher than control | Increase: damaged-strengthened avg. 36, undamaged-strengthened 66.5 | higher than control | 72 | |||||
| Cumulative energy dissipation increase as compared to control (%) | 72 | 300 for damaged-strengthened and 600 for undamaged-strengthened | - | - | slightly higher than control | |||||
| Observed failure mode | shear failure of the joint and flexural hinging of the beam | shear failure of the joint | control: shear failure, strengthened: scheme1: debonding, scheme2: crushing of beam’s concrete, strengthened: debonding and crushing beam’s concrete | (a) debonding, beam hinging. (b) shear of rehab section, fracture of rehab rods | Small FRP delamination followed by joint shear failure | |||||
| Other results | - | - | shear strength was improved | - | - | |||||
Summary of experimental work on full-scaled BCJs externally reinforced with one FRP type.
| Number of specimens | 6BCJs full scale: 3 controls, 3 wrapped with CFRP | 1BCJ repaired + 3 full-scale BCJs strengthened with CFRP | 2BCJs | 6 full-scale corner BCJ | ||||
| Test parameters | column reinf. configuration, num. of layers + CFRP wrapping configuration | types of beam anchorage detailing | number of CFRP sheets | presence of CFRP strengthening under the slab, fibers orientation, CFRP thickness, column confinement with CFRP sheets, concrete compressive strength | ||||
| Cross-section (mm2) | 300 × 500 | 300 × 300 | 260 × 600 | 260 × 260 | 350 × 400 | 350 × 350 | (a) 300 × 500, (b) stub: 300 × 500 | 300 × 300 |
| Internal main reinforcement | 3 Ø 20 top + 2 Ø 20 bottom | 6 Ø 20 continuous or with lap splicing | 4 Ø 16 top + 4 Ø 16 bottom | top part: 4 Ø 16, bot part: 8 Ø 16 | 4 Ø 18 top + 4 Ø 18 bottom | 12 Ø 18 | (a) 5 Ø 16 top + 3 Ø 16 bottom, (b) 3 Ø 16 top + 2 Ø 16 bottom | 4Ø16 |
| Internal shear reinf. (leg/mm) | 2 Ø 10 @ 150 mm + 2 Ø 10 @ 75 mm in tip | 2 Ø 10 @ 75 mm | 2 Ø 8 @ 150 mm | 2 Ø 8 @ 150 mm | 2 Ø 10 @ 100 mm | 2 Ø 10 @ 100mm | Ø8 @ 200 mm | Ø8 @ 200 mm |
| Reinf. yield strength (MPa) | 420 | Ø16: 551, Ø8: 612 | Ø18: 417, Ø10: 282 | 470 | ||||
| FRP type | CFRP | CFRP | CFRP | CFRP | ||||
| FRP shape and configuration | unidirectional CFRP U-shaped and straight sheets and strips | Sheets | unidirectional CFRP sheets | unidirectional and quadriaxial sheets | ||||
| FRP thickness (mm) | 0.176 | 0.185 | - | 0.053 | ||||
| Number of FRP layers | 1, 2, 3 | 1, 2, 3 | 1, 2, 3 | 1, 2 | ||||
| FRP tensile strength (MPa) | 3800 | 4140 | 4100 | Uniaxial = 2540, quadriaxial = 3450 | ||||
| Concrete compressive strength (MPa) | 26 | 24 | <15, 15 to 20 | 24.25 and 19.60 | avg. 25.5 | |||
| Load type | cyclic loading on column tip + 700 kN const. axial load | reversed cyclic loading + 150 kN column axial load | cyclic loading | Cyclic loading | ||||
| Peculiarity | CFRP belts to stop the slippage of longitudinal beam bot. reinf. + to prevent debonding of the U-shaped beam’s wraps | replacing the damaged concrete with high-strength-concrete in the joint core | steel angles on top and bottom face of the beam to carry the tensile forces to column | presence of slab | ||||
| Max. lateral load capacity | avg. increase: pull 61%, push: 118% | rehab.: increase 44%, strengthened: increase avg. 108% | avg. increase: pull 17%, push 32% | Increased: 96% | ||||
| DR of max. capacity (%) | control avg. pull = 1.11, push = 1.1. wrapped avg. pull = 1.72, push = 2.35 | rehab.: 2 | avg.: pull increase 44, push decrease 34 | 2.3 | ||||
| Ductility | - | increased by 97% and 50% | did not significantly increase | |||||
| Cumulative energy dissipation | control avg.7.6 kN·m, disp. 35 mm. wrapped avg. 33 kN·m, disp. 69 mm | strengthened higher than control | 1st BCJ decrease 15%, 2nd BCJ increase 60% | increased by 31.5% | ||||
| Observed failure mode | control: joint shear + debonding of beam bottom bar. wrapped: debonding + the rupture of CFRP sheets at the beam faces out of joint | control and rehab.: joint shear failure, strengthened: rupture of CFRP sheets | CFRP debonding and rupture | CFRP debonding with joint shear failure, or with column flexural hinging, flexural hinging with CFRP rupture | ||||
| Other results | delay in stiffness degradation of CFRP BCJ compared to control BCJ | - | using steel angles with round corners helped decrease the stress concentration on corners | - | ||||
| Number of specimens | 3 NS BCJs strengthened, 1 control NS | 1 full-scale BCJ tested and repaired with CFRP | 1 RC structure with multiple joints | |||||
| Test parameters | number of CFRP layers | repaired and not repaired | column dimensions, GFRP configurations PGA level (a—0.2, b—0.3 g) | |||||
| Cross-section (mm2) | 200 × 200 | 167 × 167 | 250 × 500 | 500 × 250 | 250 × 500 | (a) 8 col.s: 250 × 250, (b) 1 col.: 250 × 750 | ||
| Internal main reinforcement | 6 Ø 16 | 6 Ø 10 | 5 Ø 18 top + 5 Ø 18 bottom | 8 Ø 18 | Ø12 and Ø20 | (a) 4 Ø 12, (b) 10 Ø 12 | ||
| Internal shear reinf. (leg) | 2 Ø 10 @ 100 mm | 2 Ø 4 @ 134 mm | 2 Ø 10 @ 100 mm | 2 Ø 10 @ 150 mm | Ø8 @ 200 mm | Ø8 @ 250 mm | ||
| Reinf. yield strength (MPa) | Ø16: 550, Ø12: 551, Ø10: 322 | 292.5 | smooth reinf.: 320 | |||||
| FRP type | CFRP | CFRP | GFRP | |||||
| FRP shape and configuration | different ratios of CFRP sheets | flat and X-shaped sheets | unidirectional and quadriaxial laminates | |||||
| FRP thickness (mm) | 0.11 | - | uni-axial = 0.48, quadriaxial = 0.1096 | |||||
| Number of FRP layers | 1, 2, 3, 6, 12 | - | - | |||||
| FRP tensile strength (MPa) | - | - | uni-axial =1314, quadriaxial= 986 | |||||
| Concrete compressive strength (MPa) | 40 | 8.05 | avg. 25.5 | |||||
| Load type | cyclic loading by a 600 kN hydraulic actuator | Quasi static cyclic loading | pseudo-dynamic | |||||
| Peculiarity | modify the column square shape to round shape before wrapping the CFRP sheets | use low concrete strength, and plain round reinf. bars, weld the beam hooks with column main reinforcement | - | |||||
| Max. lateral load capacity | increase by avg. 113% | decrease: pull 22%, push 25% | ||||||
| DR of max. capacity(mm) | - | - | top displacement: | |||||
| ductility | - | decreased | - | |||||
| Cumulative energy dissipation as compared to control (%) | avg. increase 242 | decrease 4 | ||||||
| Observed failure mode | Shear failure because the CFRP rupture, beam flexure failure far from column face | joint shear failure due to debonding of x-shaped sheets on the joint surface | N/A | |||||
| Other results | stiffness lower than the control specimen | column confinement increased the plastic hinge capacity | ||||||
Summary of experimental work on scaled-down BCJs externally reinforced with FRP.
| BCJs | [ | [ | [ | |||
|---|---|---|---|---|---|---|
| Beam | Column | Beam | Column | Beam | Column | |
| Type of study | Experimental and analytical study | Experimental study | Experimental study | |||
| Number of specimens | 4 NS BCJs damaged-strengthened, 1 control NS, and 1 (S) seismic | 8BCJs 1/3 scale: 1 (NS) non-seismic, 1 (SD)seismic, 6 damaged+ strengthened | 18BCJ 2/3 scale | |||
| Test parameters | number of CFRP layers, loading drift ratio | configuration of CFRP sheets, the presence of strips | area fraction of FRP; distribution of FRP between the beam and the column; column axial load; internal joint steel reinforcement; initial damage; FRP type and configuration; effect of transverse beams | |||
| Cross-section (mm2) | 300 × 300 | 300 × 400 | 134 × 200 | 200 × 300 | 200 × 300 | 200 × 200 |
| Internal main reinforcement | 4 Ø 18 top + 4 Ø 18 bottom | 8 Ø 18 | 4 Ø 10 top + 2 Ø 10bottom | 4 Ø 12 top + 4 Ø 12 bottom | 3 Ø 14 top + 3 Ø 14 bottom | 4 Ø 14 |
| Internal shear reinforcement (leg) | S: 2 Ø 10 @ 70 mm NS: 2 Ø 10 @ 150 mm | NS: 2 Ø 4 @ 87 mm, S: 2 Ø 4 @ 44 mm | 2 Ø 10 @ 75 mm | 2 Ø 8 @ 150 mm | 2 Ø 8 @ 100 mm | |
| Reinforcement yield strength (MPa) | Ø18: 533.3, Ø10: 509.9 | 459 | longitudinal: 585, shear: 220 | |||
| FRP type | CFRP | CFRP | CFRP, GFRP | |||
| FRP shape and configuration | L-shaped, U-shaped and flat-shaped CFRP laminates | T-shaped, L-shaped, X-shaped, strips | sheets, strips | |||
| FRP thickness (mm) | 0.167 | 0.33 | CFRP = 0.13, GFRP = 0.17 | |||
| Number of FRP layers | 1, 2 | 1, 2 | 2, 3, 4, 5, 6 | |||
| FRP tensile strength (MPa) | 4950 | 4965.8 | CFRP strips = 2400, CFRP sheets = 3450, GFRP sheets = 2170 | |||
| Concrete compressive strength (MPa) | 38.6 | 36.5 | avg. 25 | |||
| Load type | reversed cyclic loading | cyclic loading by a 500 kN actuator applied on tip of column | simulated seismic load | |||
| Peculiarity | - | - | use of lateral beam, use of anchorages with or without the lateral beam | |||
| Max. lateral load capacity (kN) | improved or equal to the control one | 11.27 kN with an avg. increment of 18.22% compared to NS non-retrofitted specimen | without transverse beam: avg. 43.5 kN, with transverse beam = avg. 42.1 kN | |||
| DR of max. capacity (%) | - | - | Slightly increased | |||
| Ductility | - | Avg. of 9.24 kN·m | - | |||
| Cumulative energy dissipation | - | - | increase 70–80% | |||
| Observed failure mode | N/A | shear failure for NS, beam flexure failure for CFRP-strengthened | FRP debonding | |||
| Other results | the stiffness decreased even after repair and strengthening compared to NS specimen. the damage could be repaired until 1.5% DR | increase in number of sheets increased the strength. The X-shaped was better in improving the strength | 2.5 times higher column axial load than the initial load is the most effective load, anchorages increased strength by 30% and energy dissipation by 40% | |||
Summary of experimental work on BCJs externally reinforced with more than one FRP types (CFRP, GFRP).
| BCJs | [ | [ | ||
|---|---|---|---|---|
| Beam | Column | Beam | Column | |
| Type of study | Experimental study | Experimental study | ||
| Number of specimens | 4BCJs non-seismic control and then repaired + strengthened | 12BCJs: 6 NS + 6 SD | ||
| Test parameters | beam and column cross sections, number of FRP sheets, column axial load | FRP types, and layers | ||
| Cross-section (mm2) | (1): 230 × 300, (2): 230 × 600 | (1): 280 × 820, (2): 300 × 1600 | 100 × 100 | 100 × 100 |
| Internal main reinforcement | (1): 2 Ø 13 top + 2 Ø 13 bottom, (2): 3 Ø 25 top + 3 Ø 20 bottom | (1): 4 Ø 25 + 4 Ø 22, (2): 24 Ø 28 | 4 Ø 6 | 4 Ø 6 |
| Internal shear reinforcement (leg/mm) | - | - | 2 Ø 3 @ 100 mm | 2 Ø 3 @ 100 mm |
| Reinf. yield strength (MPa) | 510 | 555.13 | ||
| FRP type | GFRP + CFRP | GFRP + CFRP | ||
| FRP shape and configuration | uni-directional sheets of GFRP and CFRP, L-shaped + U-shaped | GFRP + CFRP sheets, CFRP plates (CP) | ||
| FRP thickness (mm) | GFRP: 1.3, CFRP: 1.0 | GFRP = 0.36, CFRP = 0.11, CP = 1.2 | ||
| Number of FRP layers | 1, 2 | 1, 2 | ||
| FRP tensile strength (MPa) | GFRP = 575, CFRP = 986 | GFRP = 2250, CFRP = 3500 | ||
| Concrete compressive strength (MPa) | 19.5 | 30 | ||
| Load type | quasi-static loading | cyclic loading + 100 kN constant axial load on column | ||
| Peculiarity | - | use carbon plates in one of the strengthening schemes | ||
| Max. lateral load capacity as compared to control (%) | (1): avg. increase 52, (2): same capacity | increased in strengthened joints | ||
| DR of max. capacity | (1): 3%, (2): 4% | - | ||
| Ductility | - | SD joints were more ductile than NS joints | ||
| Cumulative energy dissipation (%) | (1): recovered 74% of its original energy, (2): recovered 76.5% of its original energy | SD: avg. 111, NS: avg. 122 | ||
| Observed failure mode | control: (1): plastic hinge in beam + (2): plastic hinge penetrated joint. repaired-strengthened: debonding and delamination. | - | ||
| Other results | series (1) maintained higher stiffness, series (2) restore same stiffness | - | ||