Literature DB >> 30964320

Comparison of Biomechanical Effects of Different Configurations of Kirschner Wires on the Epiphyseal Plate and Stability in a Salter-Harris Type 2 Distal Femoral Fracture Model.

Sermet Inal, Kadir Gok, Arif Gok, Ahmet Murat Pinar, Canan Inal.   

Abstract

BACKGROUND: We sought to investigate the different configurations of Kirschner wires used in distal femur Salter-Harris (SH) type 2 epiphyseal fracture for stabilization after reduction under axial, rotational, and bending forces and to define the biomechanical effects on the epiphyseal plate and the fracture line and decide which was more advantageous.
METHODS: The SH type 2 fracture was modeled using design software for four different configurations: cross, cross-parallel, parallel medial, and parallel lateral with two Kirschner wires, and computer-aided numerical analyses of the different configurations after reduction were performed using the finite element method. For each configuration, the mesh process, loading condition (axial, bending, and rotational), boundary conditions, and material models were applied in finite element software, and growth cartilage and von Mises stress values occurring around the Kirschner wire groove were calculated.
RESULTS: In growth cartilage, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration. In Kirschner wires, the stresses were highest in the cross configuration and lowest in the cross-parallel and parallel lateral configurations. In the groove between the growth cartilage and the Kirschner wire interface, the stresses were highest in the parallel lateral configuration and lowest in the cross configuration.
CONCLUSIONS: The results showed that the cross configuration is advantageous in fixation. In addition, in the SH type 2 epiphyseal fracture, we believe that the fixation shape should not be applied in the lateral configuration.

Entities:  

Mesh:

Year:  2019        PMID: 30964320     DOI: 10.7547/16-112

Source DB:  PubMed          Journal:  J Am Podiatr Med Assoc        ISSN: 1930-8264


  3 in total

1.  [Technique and biomechanics of Kirschner wire osteosynthesis in children].

Authors:  Theddy Slongo
Journal:  Oper Orthop Traumatol       Date:  2020-11-25       Impact factor: 1.154

2.  Biomechanical characteristics of tibio-femoral joint after partial medial meniscectomy in different flexion angles: a finite element analysis.

Authors:  Xiaohui Zhang; Shuo Yuan; Jun Wang; Bagen Liao
Journal:  BMC Musculoskelet Disord       Date:  2021-04-02       Impact factor: 2.362

3.  Comparison of two coracoid process transfer techniques on stress shielding using three-dimensional finite-element model.

Authors:  Seyyid Serif Unsal; Tugrul Yildirim; Murat Kayalar
Journal:  J Orthop Surg Res       Date:  2022-07-30       Impact factor: 2.677

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.