BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication of joint arthroplasty. The identification of microorganisms in biofilm-related PJI is challenging yet significant stage of the treatment process. Medical microbiology methods, such as pure culture isolation, remain the gold standard. However, the error rate of classical methods may vary from 10% to as high as 42% due to the inability to detect bacteria growing within biofilms. Other methods of detection are being explored to improve the management of PJI. AIM: Accurate identification of PJI contributing microorganisms in a patient with acute postoperative PJI after total hip joint arthroplasty and systemic lupus erythematosus in anamnesis. METHODS: We used microbial culture methods followed by scanning electron microscopy (SEM). RESULTS: Perioperative an intraoperative cultural analysis of 8 different culture samples of tissue and prosthetic origin was insufficient for bacterial or fungal detection. Scanning electron microscopy revealed detailed biofilm visualisation on the surface of the prosthetic component. The biofilm exterior was composed of microbial clusters made of 10 or more cells with either pear- or bottle-shaped morphology, 3-6 mcm in length and 1.5-3 mcm in diameter. Rod-shaped microorganisms of 0.7-1 mcm length and up to 0.5 mcm in diameter were found adjacent to these clusters. CONCLUSION: Additional methods for PJI agents' detection are time-and cost-effective in the case of the challenging diagnostics of biofilm-related PJI, particularly in immunocompromised patients. Using combined diagnostic approaches increases the accuracy of detection, justifies treatment strategies and improves clinical outcomes.
BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication of joint arthroplasty. The identification of microorganisms in biofilm-related PJI is challenging yet significant stage of the treatment process. Medical microbiology methods, such as pure culture isolation, remain the gold standard. However, the error rate of classical methods may vary from 10% to as high as 42% due to the inability to detect bacteria growing within biofilms. Other methods of detection are being explored to improve the management of PJI. AIM: Accurate identification of PJI contributing microorganisms in a patient with acute postoperative PJI after total hip joint arthroplasty and systemic lupus erythematosus in anamnesis. METHODS: We used microbial culture methods followed by scanning electron microscopy (SEM). RESULTS: Perioperative an intraoperative cultural analysis of 8 different culture samples of tissue and prosthetic origin was insufficient for bacterial or fungal detection. Scanning electron microscopy revealed detailed biofilm visualisation on the surface of the prosthetic component. The biofilm exterior was composed of microbial clusters made of 10 or more cells with either pear- or bottle-shaped morphology, 3-6 mcm in length and 1.5-3 mcm in diameter. Rod-shaped microorganisms of 0.7-1 mcm length and up to 0.5 mcm in diameter were found adjacent to these clusters. CONCLUSION: Additional methods for PJI agents' detection are time-and cost-effective in the case of the challenging diagnostics of biofilm-related PJI, particularly in immunocompromised patients. Using combined diagnostic approaches increases the accuracy of detection, justifies treatment strategies and improves clinical outcomes.
Entities:
Keywords:
Biofilms; Periprosthetic infection; Scanning electron microscopy
Periprosthetic joint infection (PJI) is one of the most serious complications following total joint arthroplasty. The accurate identification of microbes contributing to PJI is critical for PJI detection and treatment. However, the identification may pose a significant challenge since the diagnostic tests report both false positive and false negative results. The reference standard for diagnosing of implant-related infections is the isolation of the pathogen in pure cultures and subsequent identification using the combination of tinctorial, physiological, biochemical methods [1].Gram-positive bacteria contribute to the development of periprosthetic infection in 88% of cases. Infection by gram-negative bacteria is relatively rare (approximately 7%). The common reasons for gram-negative bacterial infection are empirical antibiotic therapy and prolonged surgical drain stay after endoprosthesis surgery. The widespread gram-negative agents are Pseudomonas aeruginosa, Acinetobacter baumanii, Klebsiella pneumoniae, Proteus spp., Enterobacter spp., Escherichia coli [2], [3], [4]. Despite recent technological advances in cultural methods, an overwhelming 10% to 42% microbial causes of all periprosthetic infections remain unidentified [5], [6].The standard microbiology approach for microbial identification can be problematic due to the inability of biofilm-forming microorganisms to grow independently in pure culture [7] along with variability in time and specifics of cultivation methods for different species [8], [9], [10].Therefore, further studies are needed to improve the management and prevention strategies of PJI.Scanning electron microscopy (SEM) is one of the effective methods for studying microbial morphology of microorganisms from clinical samples [11], [12]. However, comparative in situ studies of biofilm attached to the orthopaedic surfaces and microbial cultures are rare.We hypothesised that etiologic agents of PJI which remain undetected using standard microbial culture methods could be identified using scanning electron microscopy approach.
Case Presentation
Clinical case: patient D., 44 years old woman, presented with acute postsurgical periprosthetic joint infection (April 2018).Medical history: In January 2018, the patient underwent cementless total joint arthroplasty of the right hip. The postoperative period has been complicated by a fever of 38°C and purulent drainage of the surgical site. A month later, modular prosthetic components were revised and debrided with subsequent replacement. Following the replacement surgery, the patient has developed a fistula.Past medical history revealed that the patient had chronic systemic lupus erythematosus, chronic bronchitis, and chronic gastritis in a remission period, genetic thrombophilia and stage 2 hypertonic disease.The patient presented with the right hip fistula, right hip pain and activity limitations. In the perioperative period we suggested periprosthetic infection based on x-ray findings (Figure 1A, B and C) and cytological and microbiological analysis of the synovial fluid. During the surgery, total removal of prosthetic components followed by the debridement, articulating spacer installation and replacement of the right hip prosthesis with the x-ray control (Figure 1D).
Figure 1
Radiographs of the pelvis: A) AP view before the revision operation; B, C) Fistulograph of the right hip joint before surgery; D) AP view after the intervention
Radiographs of the pelvis: A) AP view before the revision operation; B, C) Fistulograph of the right hip joint before surgery; D) AP view after the interventionIntraoperative samples of periarticular tissues, bone fragments of the prosthetic base and prosthetic components were obtained for histological and microbiological analyses.Tissue samples were homogenised and synovial fluid samples were pelleted before inoculation. Blood agar containing 5% defibrinated blood, Baird-Parker egg yolk tellurite medium, Levine eosin methylene blueagar, Sabouraud agar and Columbia agar were used for microbiological cultures. Inoculated agar plates were incubated at 37°C for 24-48 h. Fungal cultures were incubated at 30°C for 120 h. “Anaerogas” gas generating pack sets and 72-120 h incubation at 3°C were used for anaerobic culture growth. The morphological observation was performed using ordinary staining (Gram) method.Fragments of the periprosthetic membrane (n=3) and trabecular bone samples (n=3) of periprosthetic host bone were preserved at least 48 h in 4% formalin. Bone samples were decalcified in Richman-Gelfand-Hill solution after fixation. Then samples were dehydrated and embedded in paraffin for microtome sectioning. Slides with tissue sections of 5-7 mcm were stained with hematoxylin and eosin. The visualisation was performed using AxioScope.A1 stereomicroscope. For imaging, we used AxioCam ICc 5 and Zen blue («Carl Zeiss MicroImaging GmbH», Germany) software. For each sample, at least 10 images were obtained.Metallic endoprosthetic femoral component and periprosthetic tissue samples for scanning electron microscopy was performed using standard patented procedures with authors’ modifications [11], [13] After platinum deposition in an IB-6 vacuum ion sprayer (Eiko, Japan), the surface of the implant component was examined with Zeiss EVO MA 18 scanning electron microscope (Carl Zeiss Group, Germany). The limitation was the height of the area in the study region of no more than 145 mm, which was due to the design limitations.Perioperative culture tests of the punctured material did not reveal bacterial growth. Leucocytosis in the joint fluid was 12.9 cells per microliter, and the rate of neutrophils was 67%.Microbiological study of intraoperative samples revealed a small number of Staphylococcus saprophyticus cells (< 103 CFU/ml) in one sample (synovial joint fluid). No bacterial growth has been found after the cultivation of remaining samples. Tests for both fungi and anaerobic bacteria were negative.Histological analysis of the fragments of periprosthetic membranes was conducted according to the consensus classification of Krenn and Morawitz [14] and revealed some features of conformity to type I, caused by wear particles. In a reactively modified loose fibrous connective tissue with a high density of fibroblast-like cellular elements (Figure 2A), foreign microparticles of an optically transparent material were detected surrounded by giant cells of foreign bodies. In such areas, cell density was reduced; erythrocyte diapedesis and infiltration with monocytes and lymphocytes were noted (Figure 2B). Polymorphonuclear leukocytes were not detected in any of the visual fields.
Figure 2
Reactive changes in the periprosthetic membrane: A) high cell density; B) diapedesis, clusters of giant multinuclear cells; C) osteoclastic resorption; D) osteoblastic remodelling of trabeculae in the spongy bone of the periprosthetic bed. Paraffin sections. Stained with hematoxylin and eosin. Magnification: 10 (lens), 40 (eyepiece). Scale bar = 50 microns
Reactive changes in the periprosthetic membrane: A) high cell density; B) diapedesis, clusters of giant multinuclear cells; C) osteoclastic resorption; D) osteoblastic remodelling of trabeculae in the spongy bone of the periprosthetic bed. Paraffin sections. Stained with hematoxylin and eosin. Magnification: 10 (lens), 40 (eyepiece). Scale bar = 50 micronsHistological study of spongy bone substance fragments revealed signs of remodelling, consisting of moderate osteoclastic (Figure 2C) and osteoblastic (Figure 2D) activity on the surface of bone trabeculae. The intertrabecular spaces contained fatty bone marrow with scattered foci of hematopoiesis; hyperemia and oedema were observed only on the border with the implant.Scanning microscopy detected clusters of nanoscale globular bodies in the periprosthetic connective tissue (possibly immune complexes) (Figure 3A, and B) and perivascular accumulations of lymphoid cells (Figure 3D), characteristic of systemic lupus erythematosus.
Figure 3
Morphological manifestations of systemic lupus erythematosus in the periprosthetic connective tissue: A, B and C) Deposits of nano-sized globular bodies; D) Perivascular accumulations of lymphoid cells; Electronic scans. Magnification × 22,000 (A), × 50,000 (B), × 35,000 (C), × 5,900 (D)
Morphological manifestations of systemic lupus erythematosus in the periprosthetic connective tissue: A, B and C) Deposits of nano-sized globular bodies; D) Perivascular accumulations of lymphoid cells; Electronic scans. Magnification × 22,000 (A), × 50,000 (B), × 35,000 (C), × 5,900 (D)The flat metal surface of the femoral component, free from adherent spongy bone substance fragments (Figure 4A), was covered with a biofilm shaped as amorphous layers (Figure 4B).
Figure 4
Areas of the metal implant surface with adhered fragments of spongy bone substance of the periprosthetic bed (a) and amorphous filmy substance (b). Biofilm on the surface of the metal implant: large bottle-shaped microorganisms with a characteristic “neck” and small rod-shaped microorganisms adhered on a membranous substrate (c), and a fragment of a structured biofilm (d). Electronic scans. Magnification × 450 (a) × 900 (b) × 9590 (c) × 23,000 (d)
Areas of the metal implant surface with adhered fragments of spongy bone substance of the periprosthetic bed (a) and amorphous filmy substance (b). Biofilm on the surface of the metal implant: large bottle-shaped microorganisms with a characteristic “neck” and small rod-shaped microorganisms adhered on a membranous substrate (c), and a fragment of a structured biofilm (d). Electronic scans. Magnification × 450 (a) × 900 (b) × 9590 (c) × 23,000 (d)Microbial cells with different morphological characteristics were detected on its surface. Microorganisms with a length of 3 to 6 microns and a thickness of 1.5 to 3 microns had pear-like or bottle-like elongated shapes (Figure 4C, and D). The wide base of the cells was rounded; at the narrow end of each of them, there was a ring-shaped structure that resembled a “bottleneck”. The relief of the cell surface was uneven, poorly folded. Cells that were oriented in various directions were attached to a membranous substance on the component surface.Microorganisms were located in groups of up to 10 or more cells. Rod-shaped and transversely dividing bacteria with a diameter of 0.5 μm and a length of 0.7 to 1 μm had a smooth surface. They formed clusters containing two or more cells that adhered nearby or on the surface of large cells (Figure 4 C, and D).
Discussion
At present, there has been an increase in the incidence of biofilm-related infections caused by saprotrophic or pathogenic fungi along with either Gram-positive or Gram-negative bacteria. The role of biofilm infections in orthopaedic surgery is tremendous due to the high virulence of biofilm-forming microorganisms and the high possibility of biofilm formation on the surfaces of commonly used orthopaedic components [15].Microbial biofilms can be described as structured, high-functional aggregations of microbial cells belonging to one or most commonly several species, encased into biofilm matrix and adhered to the surface. The eradication of multi-species biofilms associated with implant surfaces can be problematic as a result of poor antibiotic activity against biofilms. Metabolic, structural and functional ties between microorganisms in biofilm do not make allowances for the cultivation of clear cultures in laboratory conditions, leading to false negative test results [16]. To improve the analytical outcome, ordinary microbiology approaches can be enhanced with sophisticated methods for cultivation of each separate microorganism for each case. However, routine use of some techniques is not cost-effective. Thus, ordinary medical microbiology methods are not always effective in PJI diagnosis and should be supported by other methods.In this clinical case, repeated laboratory tests of diagnostic punctures and intraoperative samples did not reveal etiologic PJI agents despite clinically symptomatic acute inflammatory process. The single-time finding of S. saprophyticus in 1 out of 8 perioperative samples could not interpret S. saprophyticus as an etiological factor due to the low virulence of this bacteria. Taking into consideration the low number of S. saprophyticus cells in a synovial fluid sample, we believe that the contamination of one sample could occasionally occur.Scanning electron microscopy has proven its effectiveness in the visualization and identification of biofilm-forming microbes [15], [16], [17]. In this clinical case, scanning electron microscopy revealed microbial association adhered to the endoprosthesis surface. Based on morphology, the larger microbial component of the biofilm was identified as yeast and smaller – as rod-shaped bacteria [18], [19].Uncommonly, patient anamnesis included systemic lupus erythematosus (SLE). Immunodeficiencies in patients with SLE compromise the immunity so that conditional pathogens (fungal, bacterial, viral) can contribute to the infection development [20], [21]. In this case, additional methods for microbial detection are needed.Therefore, in immunocompromised patients with periprosthetic infection, the utilization of scanning electron microscopy for accurate identification is advisable. Timely diagnostics is cost-effective and allows for justified, unbiased therapy decisions. The patient voluntarily signed informed consent to a surgical procedure and participation in the study.Level of evidence: III (limitations due to the lack of patients, single case report)