Literature DB >> 30962016

Comparison of Shear Wave Elastography and Conventional Ultrasound in Assessing Kidney Function as Measured Using 51Cr-ethylenediaminetetraacetic Acid and 99Tc-Dimercaptosuccinic Acid.

Sook Sam Leong1, Jeannie Hsiu Ding Wong2, Mohammad Nazri Md Shah3, Anushya Vijayananthan2, Maisarah Jalalonmuhali4, Kwan Hoong Ng2.   

Abstract

The purpose of this study was to assess the potential of shear wave elastography (SWE) as an indicator of abnormal kidney function defined by radiolabeled glomerular filtration rate (GFR). Fifty-seven patients referred for 51Cr-ethylenediaminetetraacetic acid GFR and 99mTc-dimercaptosuccinic acid renal scintigraphy were included. Young's modulus (YM) measured with SWE and kidney length, volume, cortical thickness and parenchymal echogenicity measured with conventional ultrasound were correlated with patients' GFR and renal scintigraphy results. Spearman correlation coefficients between SWE and GFR were negative for the right (r = -0.635, p < 0.0001) and left (r = -0.817, p < 0.0001) kidneys. Positive correlations between left renal cortical thickness (r = 0.381, p = 0.04) and left kidney volume (r = 0.356, p = 0.019) with GFR were reported. SWE correctly predicted the dominant functioning kidney in 94.7% of cases. The area under the receiver operating characteristic curve for SWE (0.800) was superior to that for conventional ultrasound (0.252-0.415). The cutoff value of ≥5.52 kPa suggested a kidney function ≤60 mL/min/1.73 m2 (82.4% sensitivity and 76.2% specificity). SWE has advantages over conventional ultrasound in assessing kidney function and distinguishing the dominant functioning kidney.
Copyright © 2019 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  (51)Cr-ethylenediaminetetraacetic acid glomerular filtration rate; (99m)Tc-dimercaptosuccinic acid renal scintigraphy; Conventional ultrasound; Glomerular filtration rate; Shear wave elastography; Stiffness

Year:  2019        PMID: 30962016     DOI: 10.1016/j.ultrasmedbio.2019.01.024

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  1 in total

1.  Shear wave elastography and Doppler ultrasound in kidney transplant recipients.

Authors:  Luana Marinho Gonçalves; Gabriele Carra Forte; Tiago Garcia Holz; Lucas Lobraico Libermann; Carlos Eduardo Poli de Figueiredo; Bruno Hochhegger
Journal:  Radiol Bras       Date:  2022 Jan-Feb
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.