Natsuki Hayashi1,2, Jinhua Chen3, Noriaki Seko4,5.
Abstract
To remove chromium from wasteEntities:
Keywords: adsorbents; adsorption capacity; amidoximation; chromium removal; radiation grafting; wastewater
Year: 2018 PMID: 30960669 PMCID: PMC6404098 DOI: 10.3390/polym10070744
Source DB: PubMed Journal: Polymers (Basel) ISSN: 2073-4360 Impact factor: 4.329
Scheme 1Chemical structures of the monomers and chemical reagents used in this study.
Figure 1Batch and column mode adsorptions.
Scheme 2Process for the preparation of the amidoxime and ammonium fabric adsorbents.
Figure 2Radiation grafting of AN/MAA and CMS onto the PE/PP nonwoven fabrics in nitrogen gas. Preirradiation dose, 100 kGy for AN/MAA grafting and 50 kGy for CMS grafting; grafting temperature, 40 °C.
Figure 3Functional groups in the amidoxime and ammonium adsorbents as a function of the degree of grafting. The amidoxime adsorbent is obtained by immersing the AN/MAA-grafted fabric in a hydroxylamine solution at 80 °C for more than 15 min; and the ammonium adsorbent is obtained by immersing the CMS-grafted fabric in a trimethylamine solution at 80 °C for more than 30 min.
Figure 4FTIR/ATR spectra for (a) the PE/PP nonwoven fabric; (b) the CMS-grafted fabric with a degree of grafting of 222%; (c) the relevant ammonium adsorbent; (d) the AN/MAA-grafted fabric with a degree of grafting of 119%; and (e) the relevant amidoxime adsorbent.
Figure 5TG/DTA analysis for (a) the PE/PP nonwoven fabric; (b) the amidoxime adsorbent with a density of functional groups of 4.53 mmol/g; and (c) the ammonium adsorbent with a density of functional groups of 3.51 mmol/g.
Figure 6Chromium removing by amidoxime and ammonium adsorbents in the batch mode adsorption at (a) pH 2.0 and (b) pH 5.0. Initial chromium solution, 0.1 ppm; volume, 45 mL; density of functional groups, 4.53 mmol/g for the amidoxime adsorbent and 3.51 mmol/g for the ammonium adsorbent; adsorption time, 90 min; room temperature.
Figure 7Chromium removing by the ammonium adsorbent in the column mode adsorption at pH 5.0. Density of functional groups, 3.51 mmol/g; inflow concentration, 0.1 ppm for Cr(III) and 10 ppm for Cr(VI); flow rate, 60 mL/h; room temperature.
Figure 8Chromium removing by the amidoxime adsorbent in the column mode adsorption at pH 5.0. Density of functional groups, 4.53 mmol/g; inflow solution, 10 ppm for the Cr(III); flow rate, 60 mL/h; room temperature.