Literature DB >> 30958550

Adjustable Depth Fractional Radiofrequency Combined With Bipolar Radiofrequency: A Minimally Invasive Combination Treatment for Skin Laxity.

Erez Dayan1, Christopher Chia2, A Jay Burns3, Spero Theodorou2.   

Abstract

Increasingly, patients are seeking minimally invasive methods to tighten skin and remodel adipose tissue. A large treatment gap exists among 3 types of patients: (1) the younger demographic, who increasingly desire soft tissue tightening without traditional operations, scars, and downtime; (2) patients with soft tissue laxity who are not "severe enough" to justify an excisional procedure, but not "mild enough" to rely on liposuction with soft tissue contraction alone; and (3) those with recurrent laxity who already underwent traditional excisional procedures. In these populations, plastic surgeons risk under- or overtreating with traditional methods. The purpose of this supplement is to describe the utility of radiofrequency (RF) microneedling (Fractora modified to Morpheus8 InMode Aesthetic Solutions, Lake Forest, CA) in combination with bipolar RF (FaceTite/BodyTite, InMode Aesthetic Solutions). By combining these procedures, the aforementioned treatment gap can be addressed. The RF microneedling allows for subdermal adipose remodeling and skin tightening. Addition of bipolar RF also tightens the skin by contraction of the underlaying fibroseptal network in addition to induction of neocollagenesis, elastogenesis, and angiogenesis at skin surface temperatures of 40° to 50°C. In our experience, these technologies have been effective and safe in these patient populations. Level of Evidence: 4.
© 2019 The American Society for Aesthetic Plastic Surgery, Inc.

Entities:  

Year:  2019        PMID: 30958550      PMCID: PMC6460431          DOI: 10.1093/asj/sjz055

Source DB:  PubMed          Journal:  Aesthet Surg J        ISSN: 1090-820X            Impact factor:   4.283


Minimally invasive skin tightening and adipose reduction has long been an elusive goal of aesthetic surgery.[1-5] Multiple energy-based technologies including laser, high-intensity focused ultrasound, and radiofrequency (RF) have evolved to meet this rising demand.[1,6-12] RF technology has steadily gained popularity since the early 2000s with consecutive increases in use of 10% or more annually.[11-13] These gains encompass aesthetic surgery as well as numerous nonaesthetic applications (tissue electrodissection, cardiac catheter ablation, ophthalmic surgery, etc.).[11] Public demand for minimally invasive skin tightening continues to grow.[11] This has been in response to a widening treatment gap prevalent among 3 cohorts of patients: (1) the younger demographic, who increasingly desire soft tissue tightening without traditional operations, scars, and downtime; (2) patients with soft tissue laxity who are not “severe enough” to justify an excisional procedure, but not “mild enough” to rely on liposuction with soft tissue contraction alone; and (3) those with recurrent laxity who already underwent traditional excisional procedures. In these populations, plastic surgeons risk under- or overtreating with traditional methods. RF achieves skin tightening by thermal heating of the reticular dermis, which triggers a healing cascade leading to collagen formation.[14,15] Tissue resistance of electrical current allows for variable impedance and rates of heat generation. For example, fat is an insulator and has high resistance to current flow (producing more heat), and water is closest to a pure conductor (producing less heat).[4,16] New collagen, elastin, and blood vessel formation occurs as skin surface temperatures reach 40° to 45°C.[1,2,17-19] In contrast to laser, RF is chromophore independent and has a better safety profile for all skin types in terms of pigmentation changes.[16] There are different types of RF for medical utilization including monopolar, bipolar, fractional, and multipolar energy modes. Monopolar RF utilizes one emitting pole with the body serving as a ground. In the bipolar RF devices, there are 2 electrodes at a set distance with a current flowing between them (Figure 1). Multipolar RF utilizes multiple electrodes to emit energy at various changing directions to allow for deeper as well as more superficial penetration of energy.
Figure 1.

Bipolar radiofrequency device (Facetite, InMode Aesthetic Solutions, Lake Forest, CA).

Bipolar radiofrequency device (Facetite, InMode Aesthetic Solutions, Lake Forest, CA). Non-energy-based devices such as microneedling serve as a minimally invasive method to induce dermal collagen formation and skin resurfacing through induction of an inflammatory cascade while preserving the epidermal barrier. This technology was first introduced by Orentreich in 1995 for the treatment of atrophic scars and rhytids. It has since been successfully employed for acne, melasma, photodamage, transcutaneous drug delivery, alopecia, and skin rejuvenation.[6,9,20-23] The local injury induced by dermal penetration of the microneedles releases growth factors (ie, TFG-alpha, beta, VEGF, PDGF) that stimulate collagen and elastin fiber production, as well as angiogenesis. RF microneedling systems advance existing technology by adding heat at controlled depths (Figure 2). Similar to fractional laser, fractional RF microneedling treats segments of the skin and soft tissue, leaving islands of untreated areas to reduce recovery time. Studies have shown active dermal remodeling by 10 weeks post-procedure with increased reticular dermal volume, hyaluronic acid, and elastin content.[8,24] This purpose of this manuscript is to describe the utilization of RF microneedling (Fractora modified to Morpheus8, InMode Aesthetic Solutions) with or without bipolar RF (FaceTite/BodyTite, InMode Aesthetic Solutions).
Figure 2.

Radiofrequency microneedling device (Morpheus8, InMode Aesthetic Solutions, Lake Forest, CA).

Radiofrequency microneedling device (Morpheus8, InMode Aesthetic Solutions, Lake Forest, CA).

RADIOFREQUENCY MICRONEEDLING

The Morpheus8 (InMode Aesthetic Solutions) is a fractional RF device with programmable penetration depth and energy delivery (Figure 2). The 24 coated needles penetrate into the subdermal tissue, leading to coagulation of fat as well as contraction of the reticular dermis and surrounding connective tissue. At the same time, directional RF energy stimulates neocollagenesis, elastogenesis, and angiogenesis (Figure 3). The adjustable penetration depth and energy settings allow the clinician to customize treatment. In the face, treatment may be 1 to 2 mm, whereas for body areas a 3-mm to 4-mm depth penetration would be appropriate. There is an additional 1-mm zone of heat effect that should be accounted for when planning treatment.
Figure 3.

Illustration of radiofrequency microneedling depth and effect.

Illustration of radiofrequency microneedling depth and effect.

Treatment Procedure

Pretreatment

A detailed history and physical are obtained to determine if there are any contraindications to treatment (ie, collagen disorders, active infection, immunocompromised state, pregnancy, poor wound healing, unrealistic expectations). Valcyclovir is recommended for patients with a history of herpes simplex.

Anesthesia

Numerous anesthesia options are available depending on energy employed, depth of treatment, and patient tolerance. Topical anesthesia applied for 45 to 60 minutes can be utilized if energy is limited and tolerated by the patient. Some patients require nerve blocks or local anesthesia for higher energy settings.

Treatment

RF microneedling treatment parameters are (Table 1):
Table 1.

Radiofrequency Treatment Parameters

DepthTreatment areasDepth of penetrationRF energy levelTreatment mode (cycle/fixed)No. of sessionsWeeks between sessionsDowntime (days)
PeriorbitalBony areas, periorbital, forehead, chin2 mm15-30Cycle1-33-62-5
FacialSoft tissue, neck3 mm20-40Cycle/fixed1-33-62-5
BodyBody areas4 mm25-40Cycle/fixed1-33-62-5

RF, radiofrequency.

Radiofrequency Treatment Parameters RF, radiofrequency. Depth: automatically set for the anatomic area RF energy: varies from 5 to 62 kw Cycle mode: needles penetrate the skin and retract from the skin with every pulse Fixed mode: needles are inserted into the skin and energy is delivered when the footswitch is activated. The needles retract from the skin and energy stops once the footswitch is released. This can be employed for stacking of pulses when desired. Repetition mode: single pulse mode or autorepeat mode when pulses are delivered automatically with predetermined pulse repetition rate. The handpiece is applied firmly and perpendicular to the treatment area. The footswitch is pressed to deliver RF energy: one press for each pulse for sensitive and small areas like the periorbital region, or continuous press for fixed mode. The handpiece is moved to the adjacent area with an overlap of approximately 50%. The handpiece should be completely released from the skin rather than sliding the needles to avoid abrasions. Then 1 to 2 additional pulses may be applied at the same site (stacking) in fixed mode. However, pulses should not be stacked over bony areas such as the forehead, periorbita, jawline, etc. (Video 1). Minor pinpoint bleeding may be encountered. Treatment may be applied to all skin types. It is important to restrict energy when treating dark Fitzpatrick skin types by starting at 15 kw or lower, adding 5 kw of energy gradually with each treatment course (to a maximum energy level of 40 kw over soft tissue, 25 kw over bone). Higher RF energy can be applied to deeper treatment areas. When working on thin skin (ie, neck) or in bony areas (ie, forehead, jawline), energy should be reduced by 20% and stacking of pulses should be avoided.

Post-Treatment

Cooling of the skin immediately post-procedure can reduce discomfort and erythema/edema. Antibiotic ointment is typically applied 1 to 3 days post-procedure. During this time, patients should refrain from other topical agents (ie, sunscreen or makeup). Once the microneedle holes close (within 1-3 days), makeup, moisturizer, and sunscreen may be applied.

EXAMPLES OF CLINICAL APPLICATIONS OF RF MICRONEEDLING

Early Facial Aging and Recurrent Laxity After Facelift

Increasingly, young patients present with early facial aging (ie, jowls, neck skin laxity) and are not yet optimal candidates for a traditional facelift. Additionally, there is a large population of patients who already underwent a facelift and suffer from recurrent laxity. These groups are ideal candidates for RF microneedling, which reliably and safely achieves skin tightening and subdermal adipose remodeling. Similarly, in this group of patients, conventional liposuction of the neck and mandibular border often leads to unpredictable soft tissue contraction. We have noticed in our clinical practice that patients respond best to RF microneedling combined with bipolar RF (Embrace Protocol, InMode Aesthetic Solutions). The RF microneedling component allows for tightening of the skin and remodeling of the subdermal adipose tissue, and the bipolar RF (FaceTite, InMode Aesthetic Solution) produces deep tissue heating (pre- superficial-musculo-aponeurotic-system/platysma) to tighten the overlying fibroseptal network. This combination of deep and superficial energy delivery optimizes treatment and soft tissue response (Figures 4 and 5; Video 2).
Figure 4.

(A) Preoperative view of this 55-year-old woman with submental and jowl skin laxity. (B) Postoperative view of the patient 6 months after radiofrequency microneedling to jowls and submental area demonstrating improved skin laxity.

Figure 5.

(A) This is a 47-year-old woman with abdominal skin laxity. (B) Six months after bipolar radiofrequency and radiofrequency microneedling treatment of anterior abdomen. Note preoperative supraumbilical skin laxity that is improved with radiofrequency treatment and not suction assisted liposuction alone.

(A) Preoperative view of this 55-year-old woman with submental and jowl skin laxity. (B) Postoperative view of the patient 6 months after radiofrequency microneedling to jowls and submental area demonstrating improved skin laxity. (A) This is a 47-year-old woman with abdominal skin laxity. (B) Six months after bipolar radiofrequency and radiofrequency microneedling treatment of anterior abdomen. Note preoperative supraumbilical skin laxity that is improved with radiofrequency treatment and not suction assisted liposuction alone. We prospectively evaluated 247 patients (224 female, 23 male; mean age, 55 years; range, 26-67 years) undergoing this combination RF therapy for neck laxity and jowling. Their pretreatment average Baker Face Neck Classification was 3.1 (standard deviation ± 1.4). The post-treatment objective improvement was 1.4 points (standard deviation ± 1.1), and 93% of patients indicated they were pleased with their results and would undergo the procedure again. Complications included prolonged swelling >6 weeks (4.8%, 12/247), hardened area >12 weeks (3.2%, 8/247), and neuropraxia (1.2%, 3/247), which all resolved without further intervention.

Brachioplasty

According to the 2017 American Society of Aesthetic Plastic Surgery Data Bank, approximately 18,000 arm lifts were performed, up 20.1% from the prior year.[12] Despite this increasing number, brachioplasty is limited by poor scarring, dehiscence, seroma, and infection. There are often focal areas of adiposity proximal to the elbow as well as of the lateral chest that are challenging to treat with traditional arm-lift and lead to contour deformities. Ultrasonic and laser-assisted liposuction have attempted to solve this problem with superficial application of heat to induce skin tightening. However, these have been complicated by inadequate tightening (ie, inadequate generation of heat) and high risk for contour deformities. Theodorou et al described near circumferential (270 degrees) RF-assisted liposuction of the upper arms in 40 patients.[3,4] An objective plastic surgeon evaluated the results as good to excellent tightening of the soft tissue envelope in the majority of patients. There were minimal complications in this cohort (1 seroma resolved with aspiration and 1 burn treated with wound care).[3] In our clinical experience, the addition of RF microneedling to this protocol serves to augment the tightening effect of bipolar RF as well as broadens the ability to treat challenging areas such as fat pads proximal to the elbow or at the arm/axillary junction (Figure 6).
Figure 6.

(A) This is a 44-year-old woman who was bothered by backrolls. (B) Six months after treatment of backrolls with bipolar radiofrequency and radiofrequency microneedling.

(A) This is a 44-year-old woman who was bothered by backrolls. (B) Six months after treatment of backrolls with bipolar radiofrequency and radiofrequency microneedling.

Focal Areas of Excess Skin Adiposity

Common areas of localized adiposity include the axillary rolls, soft tissue proximal to the knee, as well as supra and infraumbilical region. These areas are especially challenging in patients with poor skin elasticity who do not desire skin excision but also would not retract with traditional liposuction techniques. The large number of these “in between” patients represents a treatment gap that has been shown to benefit from RF microneedling. These areas benefit from deeper treatment (4000 μm) to ablate the adipose tissue as well as maximally tighten the skin, with or without bipolar RF tightening of fibroseptal networks.

DISCUSSION

The addition of RF microneedling to bipolar RF in the face and body has allowed for a safe, reliable, and effective treatment of patients who fall into the aforementioned treatment gap. In properly selected patients, we have combined these technologies to the application of RF heat from the superficial and deep directions and achieved satisfactory results without increased complications. Bipolar RF provides deep heat generation to the overlaying soft tissue and ultimately reticular dermis. Utilizing a parachute analogy, the heat contracts the strings (fibroseptal network) holding the parachute (ie, skin) in place, leading to a uniform and concerted contraction effect from below. The addition of RF microneedling augments our results by heating tissue from the superficial surface directly to the dermis and subdermal elements. One significant advantage of the RF microneedling treatment is the ability to directly generate heat in the subdermal adipose tissue and impact the contour of fat in this region while tightening the overlaying dermis. Numerous clinical studies support the efficacy of RF therapy for aesthetic skin tightening of the face and body. The goal of RF therapy is not to replace excisional procedures when indicated, but rather to achieve skin tightening in the “treatment gap” population, broadening the plastic surgeon’s armamentarium. Seo et al compared facial soft tissue laxity improvement with RF vs surgical facelift employing blinded grading of photographs. They demonstrated a 49% improvement in skin laxity relative to baseline for surgical facelift compared with 16% for fractional RF. Further, the mean laxity improvement from a single fractional RF treatment was 37% of the surgical facelift.[25] Peterson et al also studied objective measurements of mechanical skin properties and demonstrated a statistically significant improvement (5%-12% decrease in Young’s modulus and 10%-16% decrease in retraction time) as well as 1.42 grade improvement on the Fitzpatrick scale for wrinkles and 0.66 on the Alexiades scale for skin laxity, increasing to 1.57 and 0.70, respectively, improvement at 6 months. Patient satisfaction was noted to be “very high” for >90% of patients.[17] As demonstrated in this manuscript, our clinical experience has shown that the combination of bipolar RF and RF microneedling can achieve substantial skin tightening and subdermal adipose coagulation and necrosis in patients who are not candidates or prefer to not undergo surgery. Complications are rare when employed judiciously in the appropriately selected patients; however, they may include thermal burns, contour deformities, and superficial nerve injury. There are a number of limitations to our study including the subjectivity of the Baker face scale as well as patient satisfaction survey. There are more objective scales that are currently being applied to prospectively collected data including the Fitzpatrick wrinkle scale and Alexiades skin laxity scale as well as surface area measurements.

CONCLUSIONS

The demand for minimally invasive solutions to avoid traditional operative treatment continues to increase. RF technology has emerged as an effective method to safely tighten skin and reduce underlying adipose tissue. As our armamentarium expands, we have the opportunity to treat large portions of the population who were previously considered premature or borderline candidates for excisional operations. In our experience, combination RF technology (RF microneedling and bipolar RF) advances and broadens our ability to achieve tissue retraction that does not reliably occur with other energy-based devices and liposuction alone.

Disclosures

Dr Dayan is a Consultant to InMode Aesthetic Solutions and Owner of wikiPlasticSurgery.com. Drs Chia and Theodorou are Consultants to InMode Aesthetic Solutions. Dr Burns is a Consultant to Allergan, HINTMD, InMode Aesthetic Solutions, and Sciton.

Funding

This article was supported by the InMode Corporation (Toronto, Canada), who co-funded the development of this supplement. Click here for additional data file. Click here for additional data file.
  24 in total

Review 1.  Selective electro-thermolysis in aesthetic medicine: a review.

Authors:  Neil S Sadick; Yuriko Makino
Journal:  Lasers Surg Med       Date:  2004       Impact factor: 4.025

2.  Evaluation of the effect of fractional laser with radiofrequency and fractionated radiofrequency on the improvement of acne scars.

Authors:  Jennifer D Peterson; Melanie D Palm; Monika G Kiripolsky; Isabella C Guiha; Mitchel P Goldman
Journal:  Dermatol Surg       Date:  2011-08-11       Impact factor: 3.398

Review 3.  Nonablative cutaneous remodeling using radiofrequency devices.

Authors:  Tina S Alster; Jason R Lupton
Journal:  Clin Dermatol       Date:  2007 Sep-Oct       Impact factor: 3.541

4.  Improvement in arm and post-partum abdominal and flank subcutaneous fat deposits and skin laxity using a bipolar radiofrequency, infrared, vacuum and mechanical massage device.

Authors:  Lori Brightman; Elliot Weiss; Anne M Chapas; Julie Karen; Elizabeth Hale; Leonard Bernstein; Roy G Geronemus
Journal:  Lasers Surg Med       Date:  2009-12       Impact factor: 4.025

5.  Nonexcisional tissue tightening: creating skin surface area reduction during abdominal liposuction by adding radiofrequency heating.

Authors:  Diane Irvine Duncan
Journal:  Aesthet Surg J       Date:  2013-11-01       Impact factor: 4.283

6.  Skin rejuvenation by microneedle fractional radiofrequency treatment in Asian skin; clinical and histological analysis.

Authors:  Kyu Young Seo; Moon Soo Yoon; Dong Hyun Kim; Hee Jung Lee
Journal:  Lasers Surg Med       Date:  2012-08-30       Impact factor: 4.025

7.  Radiofrequency-assisted liposuction device for body contouring: 97 patients under local anesthesia.

Authors:  Spero J Theodorou; Robert J Paresi; Christopher T Chia
Journal:  Aesthetic Plast Surg       Date:  2012-03-31       Impact factor: 2.326

8.  Bipolar fractional radiofrequency treatment induces neoelastogenesis and neocollagenesis.

Authors:  Basil M Hantash; Anan Abu Ubeid; Hong Chang; Reza Kafi; Bradley Renton
Journal:  Lasers Surg Med       Date:  2009-01       Impact factor: 4.025

9.  Transepidermal retinoic acid delivery using ablative fractional radiofrequency associated with acoustic pressure ultrasound for stretch marks treatment.

Authors:  Maria Cláudia Almeida Issa; Luiza Erthal de Britto Pereira Kassuga; Natalia Stroligo Chevrand; Livia do Nascimento Barbosa; Ronir Raggio Luiz; Luciana Pantaleão; Enoi Guedes Vilar; Mayra Carrijo Rochael
Journal:  Lasers Surg Med       Date:  2012-12-31       Impact factor: 4.025

10.  Skin rejuvenation by microneedle fractional radiofrequency and a human stem cell conditioned medium in Asian skin: a randomized controlled investigator blinded split-face study.

Authors:  Kyu Young Seo; Dong Hyun Kim; Sang Eun Lee; Moon Soo Yoon; Hee Jung Lee
Journal:  J Cosmet Laser Ther       Date:  2013-02       Impact factor: 2.247

View more
  6 in total

1.  Multimodal Radiofrequency Application for Lower Face and Neck Laxity.

Authors:  Erez Dayan; Paolo Rovatti; Sherell Aston; Christopher T Chia; Rod Rohrich; Spero Theodorou
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-08-26

2.  Two-stage Radiofrequency-assisted Lipoabdominoplasty.

Authors:  Michael J Stein; Spero Theodorou; Christopher T Chia
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-04-25

3.  A Prospective Trial: Handsfree Thermoregulated Bipolar Radiofrequency for Face and Neck Contouring.

Authors:  Erez Dayan; Anne Chapas; Joseph Marte; Christopher Chia; Spero Theodorou
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-03-28

4.  Not all Radiofrequency Devices Are Created Equal: A Thermal Assessment.

Authors:  Erez Dayan; Spero Theodorou
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-02-04

5.  A Systematic Review of Subsurface Radiofrequency Treatments in Plastic Surgery.

Authors:  Eric Swanson
Journal:  Ann Plast Surg       Date:  2022-01-26       Impact factor: 1.763

6.  Combined Treatment of Monopolar and Bipolar Radiofrequency Increases Skin Elasticity by Decreasing the Accumulation of Advanced Glycated End Products in Aged Animal Skin.

Authors:  Seyeon Oh; Nark-Kyoung Rho; Kyung-A Byun; Jin Young Yang; Hye Jin Sun; Miran Jang; Donghwan Kang; Kuk Hui Son; Kyunghee Byun
Journal:  Int J Mol Sci       Date:  2022-03-10       Impact factor: 5.923

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.