Literature DB >> 30952659

Sensitive and Specific Whole-Cell Biosensor for Arsenic Detection.

Xiaoqiang Jia1,2,3, Rongrong Bu4, Tingting Zhao4, Kang Wu5.   

Abstract

Whole-cell biosensors (WCBs) have been designed to detect As(III), but most suffer from poor sensitivity and specificity. In this paper, we developed an arsenic WCB with a positive feedback amplifier in Escherichia coli DH5α. The output signal from the reporter mCherry was significantly enhanced by the positive feedback amplifier. The sensitivity of the WCB with positive feedback is about 1 order of magnitude higher than that without positive feedback when evaluated using a half-saturation As(III) concentration. The minimum detection limit for As(III) was reduced by 1 order of magnitude to 0.1 µM, lower than the World Health Organization standard for the arsenic level in drinking water, 0.01 mg/liter or 0.13 µM. Due to the amplification of the output signal, the WCB was able to give detectable signals within a shorter period, and a fast response is essential for in situ operations. Moreover, the WCB with the positive feedback amplifier showed exceptionally high specificity toward As(III) when compared with other metal ions. Collectively, the designed positive feedback amplifier WCB meets the requirements for As(III) detection with high sensitivity and specificity. This work also demonstrates the importance of genetic circuit engineering in designing WCBs, and the use of genetic positive feedback amplifiers is a good strategy to improve the performance of WCBs.IMPORTANCE Arsenic poisoning is a severe public health issue. Rapid and simple methods for the sensitive and specific monitoring of arsenic concentration in drinking water are needed. In this study, we designed an arsenic WCB with a positive feedback amplifier. It is highly sensitive and able to detect arsenic below the WHO limit level. In addition, it also significantly improves the specificity of the biosensor toward arsenic, giving a signal that is about 10 to 20 times stronger in response to As(III) than to other metals. This work not only provides simple but effective arsenic biosensors but also demonstrates the importance of genetic engineering, particularly the use of positive feedback amplifiers, in designing WCBs.
Copyright © 2019 American Society for Microbiology.

Entities:  

Keywords:  arsenic resistance; positive feedback amplifier; sensitivity; specificity; whole-cell biosensor (WCB)

Mesh:

Substances:

Year:  2019        PMID: 30952659      PMCID: PMC6532043          DOI: 10.1128/AEM.00694-19

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  41 in total

1.  The Use of Whole-Cell Biosensors to Detect and Quantify Compounds or Conditions Affecting Biological Systems.

Authors:  L.H. Hansen; S.J. Sørensen
Journal:  Microb Ecol       Date:  2001-12       Impact factor: 4.552

2.  The impacts of different long-term fertilization regimes on the bioavailability of arsenic in soil: integrating chemical approach with Escherichia coli arsRp::luc-based biosensor.

Authors:  Qi-Hui Hou; An-Zhou Ma; Di Lv; Zhi-Hui Bai; Xu-Liang Zhuang; Guo-Qiang Zhuang
Journal:  Appl Microbiol Biotechnol       Date:  2014-04-01       Impact factor: 4.813

Review 3.  Advances in arsenic biosensor development--a comprehensive review.

Authors:  Hardeep Kaur; Rabindra Kumar; J Nagendra Babu; Sunil Mittal
Journal:  Biosens Bioelectron       Date:  2014-08-07       Impact factor: 10.618

Review 4.  Making bio-sense of toxicity: new developments in whole-cell biosensors.

Authors:  Søren J Sørensen; Mette Burmølle; Lars H Hansen
Journal:  Curr Opin Biotechnol       Date:  2006-01-11       Impact factor: 9.740

5.  Functional characterization of Gram-negative bacteria from different genera as multiplex cadmium biosensors.

Authors:  Lara Bereza-Malcolm; Sanja Aracic; Ruban Kannan; Gülay Mann; Ashley E Franks
Journal:  Biosens Bioelectron       Date:  2017-03-16       Impact factor: 10.618

6.  A modular positive feedback-based gene amplifier.

Authors:  Goutam J Nistala; Kang Wu; Christopher V Rao; Kaustubh D Bhalerao
Journal:  J Biol Eng       Date:  2010-02-26       Impact factor: 4.355

7.  Heavy metal contamination and human health risk assessment in drinking water from shallow groundwater wells in an agricultural area in Ubon Ratchathani province, Thailand.

Authors:  Pokkate Wongsasuluk; Srilert Chotpantarat; Wattasit Siriwong; Mark Robson
Journal:  Environ Geochem Health       Date:  2013-06-16       Impact factor: 4.609

8.  Development of bacteria-based bioassays for arsenic detection in natural waters.

Authors:  Elizabeth Diesel; Madeline Schreiber; Jan Roelof van der Meer
Journal:  Anal Bioanal Chem       Date:  2009-04-18       Impact factor: 4.142

Review 9.  The evolution of the bacterial luciferase gene cassette (lux) as a real-time bioreporter.

Authors:  Dan Close; Tingting Xu; Abby Smartt; Alexandra Rogers; Robert Crossley; Sarah Price; Steven Ripp; Gary Sayler
Journal:  Sensors (Basel)       Date:  2012-01-11       Impact factor: 3.576

10.  A 'resource allocator' for transcription based on a highly fragmented T7 RNA polymerase.

Authors:  Thomas H Segall-Shapiro; Adam J Meyer; Andrew D Ellington; Eduardo D Sontag; Christopher A Voigt
Journal:  Mol Syst Biol       Date:  2014-07-30       Impact factor: 11.429

View more
  11 in total

1.  A Sensitive Magnetic Arsenite-Specific Biosensor Hosted in Magnetotactic Bacteria.

Authors:  Anissa Dieudonné; Sandra Prévéral; David Pignol
Journal:  Appl Environ Microbiol       Date:  2020-07-02       Impact factor: 4.792

2.  Biosensor-Based Multigene Pathway Optimization for Enhancing the Production of Glycolate.

Authors:  Shumin Xu; Linpei Zhang; Shenghu Zhou; Yu Deng
Journal:  Appl Environ Microbiol       Date:  2021-05-26       Impact factor: 4.792

3.  Development of a whole-cell biosensor for detection of antibiotics targeting bacterial cell envelope in Bacillus subtilis.

Authors:  Jianhua Yin; Dan Cheng; Yiling Zhu; Yanqun Liang; Zhiliang Yu
Journal:  Appl Microbiol Biotechnol       Date:  2022-01-11       Impact factor: 4.813

4.  Time-Dependent Biosensor Fluorescence as a Measure of Bacterial Arsenic Uptake Kinetics and Its Inhibition by Dissolved Organic Matter.

Authors:  Hyun Yoon; Andrea Giometto; Martin P Pothier; Xuhui Zhang; Alexandre J Poulain; Matthew C Reid
Journal:  Appl Environ Microbiol       Date:  2022-08-01       Impact factor: 5.005

5.  Development of Whole-Cell Biosensors for Screening of Peptidoglycan-Targeting Antibiotics in a Gram-Negative Bacterium.

Authors:  Jianhua Yin; Yiling Zhu; Yanqun Liang; Yuke Luo; Jie Lou; Xiao Hu; Qiu Meng; Tingheng Zhu; Zhiliang Yu
Journal:  Appl Environ Microbiol       Date:  2022-08-30       Impact factor: 5.005

6.  Flagellin-based electrochemical sensing layer for arsenic detection in water.

Authors:  Hajnalka Jankovics; Patrik Szekér; Éva Tóth; Balázs Kakasi; Zoltán Lábadi; András Saftics; Benjamin Kalas; Miklós Fried; Péter Petrik; Ferenc Vonderviszt
Journal:  Sci Rep       Date:  2021-02-10       Impact factor: 4.379

7.  Microfluidic Based Whole-Cell Biosensors for Simultaneously On-Site Monitoring of Multiple Environmental Contaminants.

Authors:  Yiqi Cao; Baiyu Zhang; Zhiwen Zhu; Xiayin Xin; Hongjing Wu; Bing Chen
Journal:  Front Bioeng Biotechnol       Date:  2021-03-09

8.  Sense and sensibility: of synthetic biology and the redesign of bioreporter circuits.

Authors:  Shimshon Belkin; Baojun Wang
Journal:  Microb Biotechnol       Date:  2021-10-24       Impact factor: 5.813

9.  Programming living sensors for environment, health and biomanufacturing.

Authors:  Xinyi Wan; Behide Saltepe; Luyang Yu; Baojun Wang
Journal:  Microb Biotechnol       Date:  2021-05-07       Impact factor: 6.575

10.  Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit.

Authors:  Guangbao Zhang; Shuting Hu; Xiaoqiang Jia
Journal:  Front Bioeng Biotechnol       Date:  2021-12-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.