A systematic study of molecular ion intensity and mass accuracy in low energy electron ionisation using gas chromatography-quadrupole time-of-flight mass spectrometry.

Hazel Lau1, Shao Quan Liu2, Lay Peng Tan3, Benjamin Lassabliere4, Jingcan Sun4, Bin Yu5.   

Abstract

Molecular ions, which contain accurate mass information, are valuable for providing elemental composition elucidation. Under the most common electron ionisation (EI) condition (electron energy, 70 eV and temperature, 230 °C), molecular ions are often in relatively low intensities or completely unapparent. In this research, low energy EI source parameters (electron energy and temperature) in a gas chromatography-quadrupole time of flight (GC-QTOF) were systematically studied to evaluate their correlative impact on the intensity and mass accuracy of molecular ions. Lower temperatures were generally associated with higher molecular ion intensities under various EI energies. Apart from compounds with more chemically stable molecular ion structures, the lowest electron energy (12 eV) corresponded to higher intensities. On the other hand, mass accuracy appeared to be mostly constant (≤5 ppm) at different temperatures, while improvement was observed with the use of lower electron energies (12 eV). Moreover, the effect of compound concentration on molecular ion intensity and mass accuracy was studied from 50 to 5000 ppm, and the compound-specific concentration profiles were constructed. Finally, it was found that higher column flow rates corresponded to higher intensities, while the response under 12 eV was higher than that of 70 eV. Mass accuracy remained approximately constant across different flow rates. Therefore, these findings suggest that the use of low energy EI may be a viable approach for the preservation of molecular ions.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  GC-QTOF; Low energy EI; Mass accuracy; Molecular ion intensity

Year:  2019        PMID: 30952280     DOI: 10.1016/j.talanta.2019.02.089

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Numerical Simulations and the Design of Magnetic Field-Enhanced Electron Impact Ion Source with Hollow Cylinder Structure.

Authors:  Guochen Qi; Di Tian; Guolun Gao; Guangda Liu; Chunling Qiu; Tao Long
Journal:  J Anal Methods Chem       Date:  2020-01-25       Impact factor: 2.193

Review 2.  How to identify "Material basis-Quality markers" more accurately in Chinese herbal medicines from modern chromatography-mass spectrometry data-sets: Opportunities and challenges of chemometric tools.

Authors:  Min He; Yu Zhou
Journal:  Chin Herb Med       Date:  2020-08-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.