Literature DB >> 30952247

LIBS for the detection of lead in ready to use henna paste and nutrients in fresh henna leaves and cultivated soils.

I Rehan1, M A Gondal2, K Rehan3, S Sultana4, M A Dastageer5, F F Al-Adel5.   

Abstract

Commercially available ready to use henna paste, procured from the local market in Pakistan were tested to find the level of hazardous element, lead present in the samples, using Laser Induced Breakdown Spectroscopy (LIBS). The source of lead in the ready to use henna is from the artificial chemical additives in henna paste, added to enhance the color and also to speed up the dying of the henna tattoo in hand, feet, and body. Henna tattooing is an inevitable practice in the social events in the cultures of the Indian subcontinent and the Arabian Peninsula. The frequent reckless use of henna, particularly lavishly administering it to the children is quite dangerous, although the level of lead found in the commercially available ready to use henna samples are within the permissible safe level. For the sensitive detection and quantification of lead, various experimental and plasma parameters in the LIBS detection system were optimized and the system was calibrated. The quantitative analysis of lead, carried out in five different samples of ready to use henna, using LIBS revealed that the concentration of lead in these samples is between 5.5 ± 0.2 mg Kg-1 and 16.0 ± 0.2 mg Kg-1. Moreover, LIBS elemental analysis of natural henna leaves, cultivated in Sindh and Punjab regions of Pakistan, and also the soils taken from the locations of cultivation were carried out and a correlation in the elemental compositions between the henna leaves and the cultivated soil in the proximity were studied. The quantitative analysis of LIBS results were validated by atomic absorption spectroscopy (AAS) and inductively coupled plasma-optical emission spectroscopy (ICP-OES).
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Atomic absorption spectroscopy; Detection of toxic lead; Henna analysis; Laser induced breakdown spectroscopy

Mesh:

Substances:

Year:  2019        PMID: 30952247     DOI: 10.1016/j.talanta.2019.02.047

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Rapid Determination and Quantification of Nutritional and Poisonous Metals in Vastly Consumed Ayurvedic Herbal Medicine (Rejuvenator Shilajit) by Humans Using Three Advanced Analytical Techniques.

Authors:  R K Aldakheel; M A Gondal; Hasan N Alsayed; M A Almessiere; M M Nasr; A M Shemsi
Journal:  Biol Trace Elem Res       Date:  2021-11-20       Impact factor: 4.081

Review 2.  Enhanced Laser-Induced Breakdown Spectroscopy for Heavy Metal Detection in Agriculture: A Review.

Authors:  Zihan Yang; Jie Ren; Mengyun Du; Yanru Zhao; Keqiang Yu
Journal:  Sensors (Basel)       Date:  2022-07-29       Impact factor: 3.847

Review 3.  Application of Laser-Induced Breakdown Spectroscopy and Chemometrics for the Quality Evaluation of Foods with Medicinal Properties: A Review.

Authors:  Muhammad Hilal Kabir; Mahamed Lamine Guindo; Rongqin Chen; Alireza Sanaeifar; Fei Liu
Journal:  Foods       Date:  2022-07-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.