| Literature DB >> 30948613 |
Ashokan Arumugam1, Andrew Strong1, Eva Tengman1, Ulrik Röijezon2, Charlotte K Häger1.
Abstract
INTRODUCTION: An anterior cruciate ligament (ACL) injury affects knee proprioception and sensorimotor control and might contribute to an increased risk of a second ACL injury and secondary knee osteoarthritis. Therefore, there is a growing need for valid, reliable and responsive knee proprioception tests. No previous study has comprehensively reviewed all the relevant psychometric properties (PMPs) of these tests together. The aim of this review protocol is to narrate the steps involved in synthesising the evidence for the PMPs of specific knee proprioception tests among individuals with an ACL injury and knee-healthy controls. METHODS AND ANALYSIS: The Preferred Reporting Items for Systematic reviews and Meta-Analyses will be followed to report the review. A combination of four conceptual groups of terms-(1) construct (knee proprioception), (2) target population (healthy individuals and those with an ACL injury managed conservatively or with a surgical reconstruction), (3) measurement instrument (specific knee proprioception tests) and (4) PMPs (reliability, validity and responsiveness)-will be used for electronic databases search. PubMed, AMED, CINAHL, SPORTDiscus, Web of Science, Scopus, the Cochrane Central Register of Controlled Trials and ProQuest will be searched from their inception to November 2018. Two reviewers will independently screen titles, abstracts and full text articles, extract data and perform risk of bias assessment using the updated COnsensus-based Standards for the selection of health Measurement INstruments risk of bias checklist for the eligible studies. A narrative synthesis of the findings and a meta-analysis will be attempted as appropriate. Each PMP of knee proprioception tests will be classified as 'sufficient', 'indeterminate' or 'insufficient'. The overall level of evidence will be ascertained using an established set of criteria. ETHICS AND DISSEMINATION: Ethical approval or patient consent is not required for a systematic review. The review findings will be submitted as a series of manuscripts for peer-review and publication in scientific journals. PROSPERO REGISTRATION NUMBER: CRD42018108014. © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.Entities:
Keywords: knee; musculoskeletal disorders; orthopaedic sports trauma; rehabilitation medicine; sports medicine
Year: 2019 PMID: 30948613 PMCID: PMC6500280 DOI: 10.1136/bmjopen-2018-027241
Source DB: PubMed Journal: BMJ Open ISSN: 2044-6055 Impact factor: 2.692
Operational definitions of domains, psychometric properties and subsets of psychometric properties for the purpose of this review
| Domains | Psychometric properties | Subsets of psychometric properties | Definitions adapted from COSMIN recommendations (except where indicated) |
| Reliability | The degree to which scores for (symptomatic or asymptomatic) individuals, who have not changed, are the same for repeated measurement of knee proprioception and free from measurement error. | ||
| Test–retest | The extent of agreement in repeated measurements of knee proprioception using a specific test over time. | ||
| Inter-rater | The extent of agreement between raters investigating knee proprioception scores on the same individual. | ||
| Intra-rater | The extent of agreement between repeated measurements of knee proprioception scores on the same individual by the same rater. | ||
| Measurement error | The systematic and random error of an individual’s score that is not attributed to true changes in knee joint proprioception to be measured. | ||
| Validity | Concerns how well the specific knee proprioception test under assessment measures the construct it is designed to measure, e.g. how well a knee JPS test measures the target joint position/angle matching? | ||
| Criterion validity | The extent to which knee proprioception measurements are an adequate reflection of a ‘gold standard’ method. As the ‘gold standard’ for each type of knee proprioception test is unclear, assessing the correlation of such tests with a reference standard (criterion) will be attempted. | ||
| Concurrent validity* | Addresses how well a knee proprioception test correlates to a reference standard (criterion) or instrument measuring a similar outcome, e.g. correlating the scores of a specific proprioception test such as JPS measured with dynamometer or angular motion chair method to that of position replication using a model, image-recorded angulation (photography method) and/or electrogoniometer method. | ||
| Predictive validity* | A focal measure of knee proprioception measured with a specific test at one point is used to predict another criterion measured at a later point of time, e.g. the scores of a proprioception test being used to predict the outcomes of an ACL reconstruction surgery, quality of life, return-to-sport or subsequent injury risk at a later time point. | ||
| Construct validity | The extent to which the scores of a specific knee proprioception test are consistent with hypotheses regarding the scores of other measurement methods or differences between known groups, given that the proprioception test validly measures the construct it is purported to measure. | ||
| Hypothesis testing: known groups or discriminative validity | The degree to which the scores of a knee proprioception test can discriminate between groups known to differ in proprioception sense (e.g. individuals with an ACL injury managed conservatively vs. those managed with reconstructive surgery or knee-healthy individuals vs. individuals with an ACL injury). | ||
| Hypothesis testing: convergent validity and discriminant (divergent) validity* | The focal measures of knee proprioception tests (e.g. JPS, TTDPM, AMEDA, etc.) show conceptual convergence or divergence between them or with other outcome measures attributed to different constructs such as quantitative sensory testing methods (e.g. mechanical, thermal or electrical pain threshold/tolerance), thigh muscle strength, quality of life, etc. Correlations with related constructs are expected to be higher than those of unrelated constructs. | ||
| Responsiveness | The ability of a knee proprioception test to detect change in proprioceptive ability over time. | ||
| Criterion approach | A focal measure of knee proprioception is consistent with a gold standard or a reference standard (idem construct validity) over time. | ||
| Construct approach | A focal measure of knee proprioception is correlated with other outcome measurement instruments or discriminated between subgroups (idem hypothesis testing) or before and after intervention, measured over a period of time. |
We expect that the definitions will evolve and become more specific because of the study methods, type of data and the findings reported in the eligible articles, further to discussion at team meetings.
*Definitions adapted from sources other than the COSMIN.
ACL, anterior cruciate ligament; AMEDA, active movement extent discrimination assessment; COSMIN, COnsensus-based Standards for the selection of health Measurement INstruments; JPS, joint position sense; TTDPM, threshold to detect passive motion.
Search terms and strategy used for the electronic databases included in our systematic review
| Database | Search Strategy |
|
| #1 (Proprioception OR Mechanoreceptors OR kinesthesis OR kinesthesia) |
|
| TX (proprioception OR kinesthes*) AND TX (knee OR "anterior cruciate ligament") AND TX ("patient outcome assessment" OR "treatment outcome" OR "outcome assessment" OR "outcome measure*" OR "joint position sense" OR "active joint position sense" OR "active joint position detection" OR "passive joint position sense" OR "passive joint position detection" OR "threshold to detect passive motion" OR "passive motion direction discrimination" OR "passive motion detection threshold" OR "threshold for motion detection" OR "threshold hunting" OR "psychophysical threshold hunting" OR "detection threshold" OR "discrimination threshold" OR "ipsilateral matching" OR "contralateral matching" OR "joint angle error" OR "distance estimation error" OR "passive recognition"" OR "direction accuracy" OR "active reproduction" OR "active movement extent discrimination" OR "force sense" OR "force perception" OR "velocity sense") AND TX ("discriminant analysis" OR "observer variation" OR "reproducibility of results" OR Psychometr* OR clinimetr* OR valid* OR "construct validity" OR "structural validity" OR "hypothesis testing" OR "concurrent validity"" OR "discriminative validity" OR "criterion validity" OR "predictive validity" OR "discriminant analysis" OR "convergent validity" OR sensitiv* OR specific* OR consistency OR precision OR accuracy OR reliab* OR reproducib* OR repeatab* OR intrarater OR interrater OR intratester OR intertester OR interobserver OR intraobserver OR interexaminer OR intraexaminer OR interindividual OR intraindividual OR "test-retest" OR "observer variation" OR correlation* OR agreement OR "measurement error" OR "standard error of measurement" OR "smallest real difference" OR "minimal detectable change" OR "minimal important difference" OR "clinically important difference" OR "meaningful change" OR "coefficient of variation" OR responsiv* OR "force sense" OR "force perception" OR "velocity sense") NOT TX (animal* OR "Pilot stud*" OR review OR "case series" OR "case report*" OR comment* OR editorial OR "letter to the editor" OR news OR "patient education handout" OR "consensus statement" OR "clinical practice guideline") Abstract Available; Document Type: Journal Article; Language: English; English Language; Research Article; Exclude MEDLINE records; Human; Language: English; Publication Type: Academic Journal AND Apply related words; Also search within the full text of the articles |
|
| ((((((((proprioception OR kinesthes*) AND (knee OR "anterior cruciate ligament") AND ("patient outcome assessment" OR "treatment outcome" OR "outcome assessment" OR "outcome measure*" OR "joint position sense" OR "active joint position sense" OR "active joint position detection" OR "passive joint position sense" OR "passive joint position detection" OR "threshold to detect passive motion" OR "passive motion direction discrimination" OR "passive motion detection threshold" OR "threshold for motion detection" OR "threshold hunting" OR "psychophysical threshold hunting" OR "detection threshold" OR "discrimination threshold" OR "ipsilateral matching" OR "contralateral matching" OR "joint angle error" OR "distance estimation error" OR "passive recognition" OR "direction accuracy" OR "active reproduction" OR "active movement extent discrimination" OR "force sense" OR "force perception" OR "velocity sense") AND ("discriminant analysis" OR "observer variation" OR "reproducibility of results" OR Psychometr* OR clinimetr* OR valid* OR "construct validity" OR "structural validity" OR "hypothesis testing" OR "concurrent validity" OR "discriminative validity" OR "criterion validity" OR "predictive validity" OR "discriminant analysis" OR "convergent validity" OR sensitiv* OR specific* OR consistency OR precision OR accuracy OR reliab* OR reproducib* OR repeatab* OR intrarater OR interrater OR intratester OR intertester OR interobserver OR intraobserver OR interexaminer OR intraexaminer OR interindividual OR intraindividual OR "test-retest" OR "observer variation" OR correlation* OR agreement OR "measurement error" OR "standard error of measurement" OR "smallest real difference" OR "minimal detectable change" OR "minimal important difference" OR "clinically important difference" OR "meaningful change" OR "coefficient of variation" OR responsiv* OR "force sense" OR "force perception" OR "velocity sense") NOT (animal* OR "Pilot stud*" OR review* OR "case series" OR "case report*" OR comment* OR editorial OR "letter to the editor" OR news OR "patient education handout" OR "consensus statement" OR "clinical practice guideline")) AND stype.exact("Scholarly Journals")) AND la.exact("English")) AND stype.exact("Scholarly Journals")) AND la.exact("English")) AND stype.exact("Scholarly Journals")) AND la.exact("English")) AND PEER(yes) |
|
| (((((Proprioception[MeSH terms] OR Mechanoreceptors[MeSH terms] OR sensory thresholds[MeSH terms] OR kinesthesis[MeSH terms] OR Proprioception[Text Word] OR Mechanoreceptors[Text Word] OR sensory thresholds[Text Word] OR kinesthesis[Text Word] OR kinesthesia[Text Word])) AND ("Knee joint"[MeSH terms] OR "lower extremity"[MeSH terms] OR "Athletic injuries"[MeSH terms] OR sports[MeSH terms] OR "joint instability"[MeSH terms] OR "leg injuries"[MeSH terms] OR "Anterior Cruciate Ligament Injuries"[MeSH terms] OR "Joint Instability"[MeSH terms] OR Rupture[MeSH terms] OR "Knee joint"[Text Word] OR "lower extremity"[Text Word] OR "Athletic injuries"[Text Word] OR sports[Text Word] OR "joint instability"[Text Word] OR "leg injuries"[Text Word] OR "Anterior Cruciate Ligament Injuries"[Text Word] OR "Joint Instability"[Text Word] OR Rupture[Text Word] OR injur*[Text Word] OR Tear[Text Word] OR surger*[Text Word] OR "Anterior Cruciate Ligament"[Text Word] OR Reconstruction[Text Word])) AND ("patient outcome assessment"[MeSH terms] OR "treatment outcome"[MeSH terms] OR "outcome assessment health care"[MeSH terms] OR "patient outcome assessment"[Text Word] OR "treatment outcome"[Text Word] OR "outcome assessment"[Text Word] OR "outcome measure*"[Text Word] OR "Joint position sense"[Text Word] OR "active joint position sense"[Text Word] OR "active joint position detection"[Text Word] OR "passive joint position sense"[Text Word] OR "passive joint position detection"[Text Word] OR "threshold to detect passive motion"[Text Word] OR "passive motion direction discrimination"[Text Word] OR "passive motion detection threshold"[Text Word] OR "threshold for motion detection"[Text Word] OR "threshold hunting"[Text Word] OR "psychophysical threshold hunting"[Text Word] OR "detection threshold"[Text Word] OR "discrimination threshold"[Text Word] OR "ipsilateral matching"[Text Word] OR "contralateral matching"[Text Word] OR "joint angle error"[Text Word] OR "distance estimation error"[Text Word] OR "passive recognition"[Text Word] OR "direction accuracy"[Text Word] OR "active reproduction"[Text Word] OR "active movement extent discrimination"[Text Word])) AND (Psychometrics[MeSH terms] OR "discriminant analysis"[MeSH terms] OR "observer variation"[MeSH terms] OR "reproducibility of results"[MeSH terms] OR Psychometrics[Text Word] OR "discriminant analysis"[Text Word] OR "observer variation"[Text Word] OR "reproducibility of results"[Text Word] OR Psychometr*[Text Word] OR clinimetr*[Text Word] OR valid*[Text Word] OR "content validity"[Text Word] OR "construct validity"[Text Word] OR "structural validity"[Text Word] OR "hypothesis testing"[Text Word] OR "concurrent validity"[Text Word] OR "discriminative validity"[Text Word] OR "criterion validity"[Text Word] OR "predictive validity"[Text Word] OR "discriminant analysis"[Text Word] OR "convergent validity"[Text Word] OR sensitiv*[Text Word] OR specific*[Text Word] OR consistency[Text Word] OR precision[Text Word] OR accuracy[Text Word] OR reliab*[Text Word] OR absolute[Text Word] OR relative[Text Word] OR reproducib*[Text Word] OR repeatab*[Text Word] OR intrarater[Text Word] OR interrater[Text Word] OR intratester[Text Word] OR intertester[Text Word] OR interobserver[Text Word] OR intraobserver[Text Word] OR interexaminer[Text Word] OR intraexaminer[Text Word] OR interindividual[Text Word] OR intraindividual[Text Word] OR "test-retest"[Text Word] OR "observer variation"[Text Word] OR coefficient[Text Word] OR correlation*[Text Word] OR agreement[Text Word] OR error[Text Word] OR "measurement error"[Text Word] OR "standard error of measurement"[Text Word] OR "smallest real difference"[Text Word] OR "minimal detectable change"[Text Word] OR "minimal important difference"[Text Word] OR "clinically important difference"[Text Word] OR "meaningful change"[Text Word] OR "coefficient of variation"[Text Word] OR responsiv*[Text Word] OR generali*[Text Word] OR interpretab*[Text Word])) NOT (animals[MeSH terms] OR animals[Text Word] OR "Pilot studies"[Text Word] OR reviews[Text Word] OR "case series"[Text Word] OR "case reports"[Text Word] OR comment[Text Word] OR commentary[Text Word] OR editorial[Text Word] OR "letter to the editor"[Text Word] OR news[Text Word] OR "patient education handout"[Text Word] OR "consensus statement"[Text Word] OR "clinical practice guideline"[Text Word]) |
|
| proprioception OR kinesthes* AND knee OR "anterior cruciate ligament" AND "patient outcome assessment" OR "treatment outcome" OR "outcome assessment" OR "outcome measure*" OR "joint position sense" OR "active joint position sense" OR "active joint position detection" OR "passive joint position sense" OR "passive joint position detection" OR "threshold to detect passive motion" OR "passive motion direction discrimination" OR "passive motion detection threshold" OR "threshold for motion detection" OR "threshold hunting" OR "psychophysical threshold hunting" OR "detection threshold" OR "discrimination threshold" OR "ipsilateral matching" OR "contralateral matching" OR "joint angle error" OR "distance estimation error" OR "passive recognition" OR "direction accuracy" OR "active reproduction" OR "active movement extent discrimination" OR "force sense" OR "force perception" OR "velocity sense" AND "discriminant analysis" OR "observer variation" OR "reproducibility of results" OR Psychometr* OR clinimetr* OR valid* OR "construct validity" OR "structural validity" OR "hypothesis testing" OR "concurrent validity" OR "discriminative validity" OR "criterion validity" OR "predictive validity" OR "discriminant analysis" OR "convergent validity" OR sensitiv* OR specific* OR consistency OR precision OR accuracy OR reliab* OR reproducib* OR repeatab* OR intrarater OR interrater OR intratester OR intertester OR interobserver OR intraobserver OR interexaminer OR intraexaminer OR interindividual OR intraindividual OR "test-retest" OR "observer variation" OR correlation* OR agreement OR "measurement error" OR "standard error of measurement" OR "smallest real difference" OR "minimal detectable change" OR "minimal important difference" OR "clinically important difference" OR "meaningful change" OR "coefficient of variation" OR responsiv* OR "force sense" OR "force perception" OR "velocity sense" AND NOT animals AND "Pilot studies" AND reviews AND "case series" AND "case reports" AND comment AND commentary AND editorial AND "letter to the editor" AND news AND "patient education handout" AND "consensus statement" AND "clinical practice guideline" AND (LIMIT-TO (DOCTYPE,"ar")) AND (LIMIT-TO (LANGUAGE,"English")) AND (EXCLUDE (SUBJAREA,"BIOC") OR EXCLUDE (SUBJAREA,"AGRI") OR EXCLUDE (SUBJAREA,"IMMU") OR EXCLUDE (SUBJAREA,"SOCI") OR EXCLUDE (SUBJAREA,"PHAR") OR EXCLUDE (SUBJAREA,"MATE") OR EXCLUDE (SUBJAREA,"CENG") OR EXCLUDE (SUBJAREA,"COMP") OR EXCLUDE (SUBJAREA,"ENVI") OR EXCLUDE (SUBJAREA,"ARTS") OR EXCLUDE (SUBJAREA,"VETE") OR EXCLUDE (SUBJAREA,"MATH") OR EXCLUDE (SUBJAREA,"PHYS") OR EXCLUDE (SUBJAREA,"BUSI") OR EXCLUDE (SUBJAREA,"CHEM") OR EXCLUDE (SUBJAREA,"DENT") OR EXCLUDE (SUBJAREA,"EART")) |
|
| #1 TS=(proprioception OR kinesthes*) |
Criteria for evaluating the quality of the psychometric properties
| Measurement property | Rating* | Criteria |
| Reliability | + | Intraclass correlation coefficient or weighted Kappa ≥ 0.70 |
| ? | Intraclass correlation coefficient or weighted Kappa not reported | |
| − | Intraclass correlation coefficient or weighted Kappa < 0.70 | |
| Measurement error | + | Smallest detectable change or limits of agreement < minimal important change† |
| ? | Minimal important change not defined | |
| − | Smallest detectable change or limits of agreement > minimal important change† | |
| Hypotheses testing for | + | The results are in accordance with the hypothesis‡ |
| construct validity | ? | Hypothesis is not defined (by the review committee) |
| − | The result is not in agreement with the hypothesis‡ | |
| Criterion validity | + | Correlation with gold/reference standard ≥ 0.70 or area under the curve ≥ 0.70 |
| ? | Not all information for ‘+’ reported | |
| − | Correlation with gold/reference standard < 0.70 or area under the curve < 0.70 | |
| Responsiveness | + | The results are in agreement with the hypothesis‡ or area under the curve ≥ 0.70 |
| ? | Hypothesis is not defined (by the review committee) | |
| − | The result is not in agreement with the hypothesis‡ or area under the curve < 0.70 |
The criteria list has been adapted from Prinsen et al.53
*Rating: ‘+’=sufficient, ‘?’=indeterminate, ‘– ‘=insufficient.
†This rating of evidence may be obtained from different studies.
‡The findings of all studies must be complied together and then it must be decided if 75% of the findings are in agreement with the hypotheses.
Levels of evidence rating for the quality of the psychometric properties
| Level | Rating* | Criteria† |
| Strong | +++ or − − − | Test‡ was evaluated in multiple studies of adequate risk of bias score or one study of very good risk of bias score (implying a low risk of bias). |
| Moderate | ++ or − − − | Test was evaluated in multiple studies of doubtful risk of bias score or one study of adequate risk of bias score. |
| Limited | + or − − − | Test was evaluated in one study of doubtful risk of bias score. |
| Conflicting | ± | Test was evaluated in studies with contradictory findings. |
| Unknown | ? | Test was evaluated in studies of inadequate risk of bias score or not investigated at all. |
Adapted from Kroman et al.54
*Sufficient (+), indeterminate (?), or insufficient (-) rating.53
†Modified using the new 4-point scoring system of the updated COSMIN checklist.38
‡A specific knee proprioception test.