Literature DB >> 30947988

A Faraday cage-type immunosensor for dual-modal detection of Vibrio parahaemolyticus by electrochemiluminescence and anodic stripping voltammetry.

Tao Wang1, Xinxin Song1, Han Lin1, Tingting Hao1, Yufang Hu1, Sui Wang1, Xiurong Su2, Zhiyong Guo3.   

Abstract

Vibrio parahaemolyticus (VP), as a kind of harmful bacterium to human beings, its rapid and accurate detection is particularly important. Herein, we developed a simple and efficient dual-modal Faraday cage-type immunosensor for ultrasensitive detection of VP based on electrochemiluminescence (ECL) and anodic stripping voltammetry (ASV). After being captured by capture unit on magnetic glassy carbon electrodes, VP was recognized by detector unit, achieving ECL and ASV dual-modal detection. Compared with traditional sandwich-type immunosensors, this proposed immunosensor has the advantages of significant signal amplification effects, due to its distinctive Faraday cage-type structure. Benefited from it, all Ru(bpy)22+ and AgNPs labeled on the detector unit could participate in the electrode reaction and generate stronger ECL and electrochemical signals respectively. Under the optimized conditions, the linear range was from 102 to 107 CFU mL-1 with a limit of detection (LOD) of 33 CFU mL-1, and the selectivity, stability and reproducibility were satisfactory. In addition, the results of two detection methods can mutually validate each other to avoid false positive results. Moreover, this Faraday cage-type immunosensor with dual-modal detection can also be used for detection of VP in seawater samples with recoveries in the range of 96.1-107.9%, which would be a promising tool for pathogenic bacteria analysis.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anodic stripping voltammetry; Dual-modal detection; Electrochemiluminescence; Faraday cage-type immunosensor; Vibrio parahaemolyticus

Mesh:

Year:  2019        PMID: 30947988     DOI: 10.1016/j.aca.2019.02.032

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  A turn-on-type fluorescence resonance energy transfer aptasensor for vibrio detection using aptamer-modified polyhedral oligomeric silsesquioxane-perovskite quantum dots/Ti3C2 MXenes composite probes.

Authors:  Juncheng Hong; Wenhai Wang; Jiaqi Wang; Xiao Wang; Hongzhen Xie; Tianhua Li; Ning Gan
Journal:  Mikrochim Acta       Date:  2021-01-21       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.