Literature DB >> 30946063

Repeatability of Noninvasive Keratograph 5M Measurements Associated With Contact Lens Wear.

María García-Montero1, Laura Rico-Del-Viejo, Amalia Lorente-Velázquez, Irene Martínez-Alberquilla, Jose Luis Hernández-Verdejo, David Madrid-Costa.   

Abstract

OBJECTIVE: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days.
METHODS: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)].
RESULTS: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level.
CONCLUSIONS: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).

Entities:  

Mesh:

Year:  2019        PMID: 30946063     DOI: 10.1097/ICL.0000000000000596

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  6 in total

1.  Comparison and Evaluation of Prelens Tear Film Stability by Different Noninvasive in vivo Methods.

Authors:  Takashi Itokawa; Takashi Suzuki; Hiroko Iwashita; Yuichi Hori
Journal:  Clin Ophthalmol       Date:  2020-12-21

2.  Repeatability and Reproducibility of SMTube Measurement in Dry Eye Disease Patients.

Authors:  Yiran Hao; Lei Tian; Kai Cao; Ying Jie
Journal:  J Ophthalmol       Date:  2021-10-08       Impact factor: 1.909

3.  Impact of Bariatric Surgery-Induced Weight Loss on Anterior Eye Health in Patients with Obesity.

Authors:  Said Karimzad; Paramdeep S Bilkhu; James S Wolffsohn; Srikanth Bellary; Hala Shokr; Rishi Singhal; Doina Gherghel
Journal:  Nutrients       Date:  2022-06-14       Impact factor: 6.706

4.  Change Patterns in Corneal Intrinsic Aberrations and Nerve Density after Cataract Surgery in Patients with Dry Eye Disease.

Authors:  Dalan Jing; Xiaodan Jiang; Xiaotong Ren; Jie Su; Shanshan Wei; Ran Hao; Yilin Chou; Xuemin Li
Journal:  J Clin Med       Date:  2022-09-27       Impact factor: 4.964

5.  Subjective Comparison of Pre-Lens Tear Film Stability of Daily Disposable Contact Lenses Using Ring Mire Projection.

Authors:  Christiane Müller; Sebastian Marx; Julia Wittekind; Wolfgang Sickenberger
Journal:  Clin Optom (Auckl)       Date:  2020-02-28

6.  The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy.

Authors:  Leandro Inferrera; Emanuela Aragona; Adam Wylęgała; Antonio Valastro; Gianluigi Latino; Elisa I Postorino; Romana Gargano; Bogusława Orzechowska-Wylęgała; Edward Wylęgała; Anna M Roszkowska
Journal:  J Clin Med       Date:  2022-03-14       Impact factor: 4.241

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.