Literature DB >> 30944263

Falsely elevated plasma ACTH levels measured by the Elecsys assay related to heterophilic antibody in a case of secondary adrenocortical insufficiency.

Koji Morita1, Masumi Ogawa2, Michiko Kimura3, Yuta Okawa4, Yutaka Oki5, Naoki Edo1, Kazuhisa Tsukamoto1, Toshio Ishikawa1.   

Abstract

A 49-year-old woman with membranous nephropathy was referred to our hospital during the tapering of oral prednisolone, because of suspicion of primary adrenal insufficiency based on a plasma ACTH level of 399.1 pg/mL in the Elecsys assay and a serum cortisol level of 3.1 μg/dL. A rapid ACTH stimulation test revealed a suboptimal response, whereas a prolonged ACTH simulation test showed a sufficient increase in her urinary free cortisol. Also, big ACTH was not detected by gel exclusion chromatography. Therefore, we speculated that ACTH levels were falsely elevated due to some interference substances. Pretreatment of her plasma with either polyethylene glycol precipitation or a heterophilic blocking tube substantially reduced her ACTH values. When either the Immulite ACTH II or the TOSOH II ACTH was tried instead of the Elecsys ACTH, her plasma ACTH values turned out to be lower and appropriate for her clinical status. These results indicated that heterophilic antibodies interfered only with the Elecsys ACTH assay presumably by bridging the capture and tracer antibodies. To our knowledge, this is the first case in which the Elecsys ACTH assay yielded falsely elevated results. Regardless of the measurement system used, if there is a discordance between assay results and clinical findings, it should be considered to adopt additional procedures and/or another assay.

Entities:  

Keywords:  Adrenal insufficiency; Adrenocorticotropic hormone (ACTH); Heterophilic antibody; Prolonged ACTH stimulation test; The Elecsys ACTH assay

Mesh:

Substances:

Year:  2019        PMID: 30944263     DOI: 10.1507/endocrj.EJ19-0023

Source DB:  PubMed          Journal:  Endocr J        ISSN: 0918-8959            Impact factor:   2.349


  3 in total

Review 1.  A Pitfall of Falsely Elevated ACTH: A Case Report and Literature Review.

Authors:  Yung-Yu Yang; Chih-Chun Kuo; Ming-Hsun Lin; Chun-Yung Chang; Chang-Hsun Hsieh; Chieh-Hua Lu
Journal:  J Investig Med High Impact Case Rep       Date:  2022 Jan-Dec

2.  Characterization of canine anti-mouse antibodies highlights that multiple strategies are needed to combat immunoassay interference.

Authors:  Daniel Bergman; Anders Larsson; Helene Hansson-Hamlin; Emma Åhlén; Bodil Ström Holst
Journal:  Sci Rep       Date:  2019-10-10       Impact factor: 4.379

3.  Letter to the Editor: Assay-specific Spurious ACTH Results Lead to Misdiagnosis, Unnecessary Testing, and Surgical Misadventure-A Case Series.

Authors:  Ghaith Altawallbeh; Amy B Karger
Journal:  J Endocr Soc       Date:  2019-11-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.