| Literature DB >> 30941602 |
Bálint Lóránt1, Miklós Gyalai-Korpos2,3, Igor Goryanin4,5,6, Gábor Márk Tardy7.
Abstract
OBJECTIVES: Single chamber air cathode microbial fuel cells (MFCs) were investigated with sodium-acetate and peptone as test substrates to assess the potential for application as biosensor to determine the concentration of biodegradable organics in water/wastewater samples.Entities:
Keywords: Air cathode; Biodegradation kinetics; Biosensor; Microbial fuel cell
Mesh:
Substances:
Year: 2019 PMID: 30941602 PMCID: PMC6482134 DOI: 10.1007/s10529-019-02668-4
Source DB: PubMed Journal: Biotechnol Lett ISSN: 0141-5492 Impact factor: 2.461
Fig. 1Scheme of the applied MFCs
Fig. 2Power density (a); Voltage (b) as a function of current in the three MFCs at 30 °C. a, b : Cell “A”; : Cell “B”; : Cell “C”
Fig. 3Internal resistance (Ri), maximum power density (Pd max) and power density measured at 1000 Ω external resistance (Pd 1000Ω) values obtained in the MFCs. : MFC “A”; : MFC “B”; : MFC “C”
Fig. 4Current generated in the cells (external resistance: 1000 Ω) as a function of operating temperature
Fig. 5Measured and modeled acetate concentrations and the obtained current as a function of time during the measurement of concentration dependence with 600 Ω external resistance. : Acetate concentration measured with gas chromatography; Acetate concentration calculated with the “hydraulic model”; Acetate concentration calculated with the “biodegradation model”; Measured current in the external circuit of the MFC
Parameters of the Monod-type concentration dependence model of the current
| Re | Imax | KS |
|---|---|---|
| 100 | 1.29 | 8.2 |
| 600 | 0.96 | 6.7 |
| 1000 | 0.57 | 4.3 |
Re: External resistance; Imax: maximum current; KS: half saturation constant
Fig. 6Obtained average current of the operated 3 MFCs with the standard deviation as a function of acetate concentration at three different external resistance (Re) values. : 100 Ω external resistance; : 600 Ω external resistance; : 1000 Ω external resistance
Fig. 7Obtained average current of the operated 3 MFCs with the standard deviation as a function of COD concentration of the media with acetate and peptone as carbon source. : Acetate based media; : Peptone based media