We propose objective and robust measures for the purpose of classification of "vaginal vs. cesarean section" delivery by investigating temporal dynamics and complex interactions between fetal heart rate (FHR) and maternal uterine contraction (UC) recordings from cardiotocographic (CTG) traces. Multivariate extension of empirical mode decomposition (EMD) yields intrinsic scales embedded in UC-FHR recordings while also retaining inter-channel (UC-FHR) coupling at multiple scales. The mode alignment property of EMD results in the matched signal decomposition, in terms of frequency content, which paves the way for the selection of robust and objective time-frequency features for the problem at hand. Specifically, instantaneous amplitude and instantaneous frequency of multivariate intrinsic mode functions are utilized to construct a class of features which capture nonlinear and nonstationary interactions from UC-FHR recordings. The proposed features are fed to a variety of modern machine learning classifiers (decision tree, support vector machine, AdaBoost) to delineate vaginal and cesarean dynamics. We evaluate the performance of different classifiers on a real world dataset by investigating the following classifying measures: sensitivity, specificity, area under the ROC curve (AUC) and mean squared error (MSE). It is observed that under the application of all proposed 40 features AdaBoost classifier provides the best accuracy of 91.8% sensitivity, 95.5% specificity, 98% AUC, and 5% MSE. To conclude, the utilization of all proposed time-frequency features as input to machine learning classifiers can benefit clinical obstetric practitioners through a robust and automatic approach for the classification of fetus dynamics.Entities:
Keywords: bivariate empirical mode decomposition; cesarean section; fetal heart rate; intrinsic mode function; uterine contraction; vaginal delivery
Year: 2019 PMID: 30941054 PMCID: PMC6433745 DOI: 10.3389/fphys.2019.00246
Source DB: PubMed Journal: Front Physiol ISSN: 1664-042X Impact factor: 4.566
Figure 1A schematic of the proposed scheme in this study. FHR, fetal heart rate; UC, uterine contraction; BEMD, bivariate empirical mode decomposition; MJiA, mean of joint instantaneous amplitude; MmAM, mean of monotonic change in AM; VmAM, variance of monotonic AM change; WMF, weighted mean frequency; ME, mean energy; PSI, phase synchronization index; IMF, intrinsic mode function.
Bivariate EMD
| 1: Let |
| 2: a unit complex number |
| 3: locate |
| 4: obtain envelope curves |
| 5: determine the arithmetic mean |
| 6: repeat until |
Figure 2Raw and processed waveforms of FHR [bpm] and UC [a.u] recordings for one representative subject of the vaginal group. (A) raw FHR, (B) raw UC, (C) processed FHR, (D) processed UC. FHR, fetal heart rate; bpm, beats per minute; UC, uterine contraction; a.u, arbitrary units.
Figure 3Intrinsic mode functions derived from bivariate empirical mode decomposition of initial 2 mins recordings of FHR (Left panels) and UC (Right panels) recordings shown in Figure 2. FHR, fetal heart rate; UC, uterine contraction; IMF, intrinsic mode function.
Figure 4Averaged values of individual features for vaginal and cesarean groups. Error bars represent standard errors. FHR, fetal heart rate; UC, uterine contraction; IMF, intrinsic mode function; AM, amplitude modulation. (A) mean of joint instantaneous amplitude, (B) mean of monotonic AM change, (C) variance of monotonic AM change, (D) weighted mean frequency of FHR, (E) weighted mean frequency of UC, (F) mean energy of FHR, (G) mean energy of UC, (H) phase synchronization index.
Group-averages (means ± standard errors) of feature values for vaginal and cesarean groups.
| MJiA (n.a.) | 6.6 ± 2.6 | 2.7 ± 0.3 | 7.4 ± 1.7 | 3.7 ± 0.5 | 10.5 ± 4.5 | 4.7 ± 0.6 | 10.3 ± 0.1 | 6.7 ± 1.3 | 16.7 ± 3.9 | 15.9 ± 6.7 |
| MmAM (n.a.) | 0.0006 ± 0.0001 | −0.0002 ± 0.0001 | 0.0005 ± 0.0003 | −0.0002 ± 0.0001 | 0.0002 ± 0.0002 | −0.0003 ± 0.0002 | −0.0003 ± 0.0007 | −0.00003 ± 0.0002 | 0.0004 ± 0.0003 | −0.0005 ± 0.0002 |
| VmAM (n.a.) | 0.09 ± 0.03 | 0.04 ± 0.005 | 0.08 ± 0.04 | 0.02 ± 0.004 | 0.04 ± 0.03 | 0.02 ± 0.003 | 0.03 ± 0.02 | 0.05 ± 0.0009 | 0.08 ± 0.04 | 0.02 ± 0.003 |
| WMFFHR (rad/se) | 0.09 ± 0.0009 | 0.09 ± 0.001 | 0.05 ± 0.001 | 0.05 ± 0.001 | 0.04 ± 0.004 | 0.03 ± 0.001 | 0.04 ± 0.005 | 0.05 ± 0.02 | 0.07 ± 0.01 | 0.08 ± 0.02 |
| WMFUC (rad/se) | 0.2 ± 0.01 | 0.1 ± 0.01 | 0.2 ± 0.02 | 0.07 ± 0.01 | 0.2 ± 0.02 | 0.04 ± 0.006 | 0.2 ± 0.02 | 0.08 ± 0.02 | 0.2 ± 0.02 | 0.1 ± 0.05 |
| MEFHR (beats2/sec3) | 1.6 ± 0.08 | 1.5 ± 0.3 | 2.4 ± 0.2 | 2.3 ± 0.3 | 2.7 ± 0.2 | 2.7 ± 0.3 | 2.9 ± 0.1 | 2.7 ± 0.3 | 3.3 ± 0.1 | 3.4 ± 0.4 |
| MEUC (mmHg2/sec) | 2 ± 0.4 | 0.9±.3 | 2.5 ± 0.4 | .99±.3 | 2.7 ± 0.4 | 1.4 ± 0.2 | 3.7 ± 0.4 | 2.5 ± 0.4 | 4.1 ± 0.4 | 3.7 ± 0.7 |
| PSI (a.u.) | 0.03 ± 0.002 | 0.04 ± 0.007 | 0.03 ± 0.002 | 0.04 ± 0.009 | 0.04 ± 0.006 | 0.04 ± 0.009 | 0.05 ± 0.004 | 0.06 ± 0.02 | 0.07 ± 0.007 | 0.1 ± 0.03 |
a.u., arbitrary units; IMF, intrinsic mode function; MJiA, mean of joint instantaneous amplitude; MmAM, mean of monotonic AM change; VmAM, variance of AM change; WMF, weighted mean frequency; ME, mean energy; PSI, phase synchronization index; FHR, fetal heart rate; UC, uterine contraction; n.a., not applicable.
Figure 5An illustration of performance measures for the RFE feature selection scheme. Panel (A) represents sensitivity, (B) represents specificity, (C) represents AUC, and (D) represents MSE. AUC, area under the ROC curve; MSE, mean squared error; RFE, recursive feature elimination.
Combinations of features corresponding to features' selection as of Figure 5.
| 3 | MmAM | ME of UC, | PSI | 0.76 | ||
| 5 | MmAM | MJiA | ME of UC, | PSI | 0.77 | |
| 7 | MmAM | MJiA | MmAM, | ME of UC, | PSI | 0.83 |
| 9 | MmAM, | MJiA | MmAM, | ME of UC, | PSI, | 0.88 |
| 13 | MmAM, | MJiA, | MmAM, | ME of UC, | PSI, | 0.94 |
| 18 | MJiA, | MJiA, | MmAM, | ME of UC, | PSI, | 0.987 |
| 20 | MJiA, | MJiA, | MmAM, | ME of UC, | PSI, | 0.998 |
| 25 | MJiA, | MJiA, | MmAM, | ME of UC, | PSI, | 0.988 |
| 35 | MJiA, | MJiA, | MmAM, | ME of UC, | PSI, | 0.983 |
| 40 | MJiA, | MJiA, | MmAM, | ME of UC, | PSI, | 0.985 |
AUC, area under the ROC curve; IMF, intrinsic mode function; MJiA, mean of joint instantaneous amplitude; MmAM, mean of monotonic AM change; VmAM, variance of AM change; WMF, weighted mean frequency; ME, mean energy; PSI, phase synchronization index; FHR, fetal heart rate; UC, uterine contraction.
Figure 6Performance measures i.e., sensitivity, specificity, AUC and MSE, using decision tree, SVM and AdaBoost classifiers for balanced and unbalanced classes. AUC, area under the ROC curve; MSE, mean squared error; SVM, support vector machine.