Literature DB >> 30935874

Bias in analytical chemistry: A review of selected procedures for incorporating uncorrected bias into the expanded uncertainty of analytical measurements and a graphical method for evaluating the concordance of reference and test procedures.

Robert Frenkel1, Ian Farrance2, Tony Badrick3.   

Abstract

The Evaluation of measurement data - Guide to the Expression of Uncertainty in Measurement (GUM) provides the framework for evaluating measurement uncertainty. The preferred GUM approach for addressing bias assumes that all systematic errors are identified and corrected at an early stage in the measurement process. We review some procedures for treating uncorrected bias and its inclusion into an overall uncertainty statement. When bias and its uncertainty are recognised as metrological states independent of scatter in the test results, the uncertainty of the reference and uncertainty of the bias can be equated. The net standard uncertainty of a test result is the root-sum-square of the standard uncertainty of the bias and the standard uncertainty of measurements on the test. Since an incomplete and therefore potentially erroneous formula is often used for estimating bias standard uncertainty, we propose an alternative calculation. We next propose a graphical method using a simple algorithm that quantifies the discrepancy between the results of a test measurement and the corresponding reference value, in terms of the percentage overlap of two probability density functions. We propose that bias should be corrected wherever possible and we illustrate this approach using the graphical method. Even though this review is focused principally on analytical chemistry and medical laboratory applications, much of the discussion is applicable to all areas of metrology.
Copyright © 2019 Elsevier B.V. All rights reserved.

Keywords:  Bias; Bias correction; Bias uncertainty; Measurement uncertainty; Overlap; Probability density function

Mesh:

Year:  2019        PMID: 30935874     DOI: 10.1016/j.cca.2019.03.1633

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  2 in total

Review 1.  Biological variation: Understanding why it is so important?

Authors:  Tony Badrick
Journal:  Pract Lab Med       Date:  2021-01-04

Review 2.  Estimation of the measurement uncertainty and practical suggestion for the description of the metrological traceability in clinical laboratories.

Authors:  Raúl Rigo-Bonnin; Noelia Díaz-Troyano; Laura García-Tejada; Albert Marcè-Galindo; Míriam Valbuena-Asensio; Francesca Canalias
Journal:  Biochem Med (Zagreb)       Date:  2020-12-15       Impact factor: 2.313

  2 in total