T Ceri1, A Podda1, J Behr2, E Brumpt2, M Alilet1, S Aubry3. 1. Department of Musculoskeletal Imaging, CHRU Besancon, 25000 Besancon, France. 2. Department of Abdominal Imaging, CHRU Besancon, 25000 Besancon, France; Laboratoire d'Anatomie, Université de Bourgogne-Franche-comté, 25000 Besancon, France. 3. Department of Musculoskeletal Imaging, CHRU Besancon, 25000 Besancon, France; Nanomedecine Laboratory INSERM EA 4662, Université de Bourgogne-Franche-comté, 25000 Besancon, France. Electronic address: radio.aubry@free.fr.
Abstract
PURPOSE: To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. MATERIAL AND METHODS: Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26-43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. RESULTS: The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43-1.31mm), 0.6±0.17 (SD) mm (range: 0.29-1.16mm) and 0.49±0.13 (SD) mm (range: 0.26-0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (-0.23mm; 27%; P<0.001), between the arcade and downstream (-0.11mm; 17%; P<0.001), and between upstream and downstream the arcade (-0.34mm; 40%; P<0.001). CONCLUSION: Disparity in AP diameter of the PIN of the elbow in the arcade of Frohse is a normal finding and should not be erroneously interpreted as entrapment when present alone.
PURPOSE: To assess the normal values of the antero-posterior (AP) diameter of the posterior interosseous nerve (PIN) of the elbow as it passes beneath the arcade of Frohse and to search for PIN-diameter differences between the upstream, entry point and downstream of the arcade. MATERIAL AND METHODS: Thirty asymptomatic patients prospectively underwent bilateral B-mode ultrasound of the PIN of the elbow. There were 15 men and 15 women with a mean age of 30.2±5.31 (SD) years (range: 26-43 years). Of these, 23 patients were right-handers (23/30; 77%) and 7 were left handers (7/30; 23%). AP diameter of the PIN was measured in long axis at three different locations including the entry point of the arcade, 5-mm upstream and 5-mm downstream the arcade. A comparison between the three measurements was performed using paired t-test. RESULTS: The mean AP diameters of the PIN were 0.83±0.21 (SD) mm (range: 0.43-1.31mm), 0.6±0.17 (SD) mm (range: 0.29-1.16mm) and 0.49±0.13 (SD) mm (range: 0.26-0.86mm) at 5-mm upstream, entry point of the arcade and 5-mm downstream the arcade of Frohse, respectively. Significant drops in PIN diameter were found between upstream and the arcade (-0.23mm; 27%; P<0.001), between the arcade and downstream (-0.11mm; 17%; P<0.001), and between upstream and downstream the arcade (-0.34mm; 40%; P<0.001). CONCLUSION: Disparity in AP diameter of the PIN of the elbow in the arcade of Frohse is a normal finding and should not be erroneously interpreted as entrapment when present alone.
Authors: Pedro Belón-Pérez; Laura Calderón-Díez; José Luis Sánchez-Sánchez; Miguel Robles-García; Gustavo Plaza-Manzano; César Fernández-de-Las-Peñas Journal: Int J Environ Res Public Health Date: 2022-02-21 Impact factor: 3.390