Literature DB >> 3093552

Dimensional stability of dental impressions after immersion disinfection.

S P Herrera, V A Merchant.   

Abstract

Disinfection of dental impressions via short-term immersion in 0.5% or 1% sodium hypochlorite does not significantly affect the dimensional accuracy of the resultant casts. In addition, immersion in glutaraldehydes, povidone-iodine diluted in water, or halogenated phenol has no apparent effect on the dimensional stability of rubber impression materials. The results of this study support the use of immersion disinfectants for treatment of impressions for study models or removable dental appliances or prostheses. Coupled with the findings of other authors, the data suggest that such disinfection also would be suitable for rubber base and vinyl polysiloxane impressions for cast restorations. Given the need for infection control in the treatment of all dental patients, the results of this study support the recommendations of the American Dental Association for disinfection of dental impressions via immersion in an appropriate disinfectant solution.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3093552     DOI: 10.14219/jada.archive.1986.0214

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  7 in total

1.  Dimensional changes of alginate dental impression materials.

Authors:  N Nallamuthu; M Braden; M P Patel
Journal:  J Mater Sci Mater Med       Date:  2006-12       Impact factor: 3.896

2.  Effect of Chemical Disinfection on Surface Detail Reproduction and Dimensional Stability of a New Vinyl Polyether Silicone Elastomeric Impression Material.

Authors:  Monika Khatri; Sneha S Mantri; Suryakant C Deogade; Abhilasha Bhasin; Shivkumar Mantri; Neetu Khatri; Priyanka Jain; Deepak Chauhan
Journal:  Contemp Clin Dent       Date:  2020-07-13

3.  The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts.

Authors:  Wala M Amin; Muna H Al-Ali; Sandra K Al Tarawneh; Sahar Th Taha; Mohamed W Saleh; Nadia Ereifij
Journal:  J Clin Med Res       Date:  2009-06-21

4.  An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization.

Authors:  Poonam K Khinnavar; B H Dhanya Kumar; D B Nandeeshwar
Journal:  J Indian Prosthodont Soc       Date:  2015 Apr-Jun

5.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

6.  Evaluation of efficacy of Aloe Vera as a Disinfectant by Immersion and Spray methods on Irreversible Hydrocolloid Impression Material and its Effect on the Dimensional Stability of Resultant Gypsum Cast - An in Vitro Study.

Authors:  Roopsi Trivedi; Rajashekar Sangur; Lakshmana Rao Bathala; Shitij Srivastava; Srishti Madhav; Preeti Chaubey
Journal:  J Med Life       Date:  2019 Oct-Dec

7.  Effect of Different Wax Pattern Manufacturing Techniques on the Marginal Fit of Lithium Disilicate Crowns.

Authors:  Huda Ahmed Alshehri; Sara Mohammed Altaweel; Raghdah Alshaibani; Esraa Ahmed Alahmari; Hanan Nejer Alotaibi; Afnan Fouzan Alfouzan; Nawaf Labban
Journal:  Materials (Basel)       Date:  2022-07-07       Impact factor: 3.748

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.