| Literature DB >> 30934745 |
Yafei Ma1,2, Baoyong Lu3, Zhongzhao Guo4, Lei Wang5,6, Hailong Chen7, Jianren Zhang8,9.
Abstract
Shear strength is a widely investigated parameter for reinforced concrete structures. The corrosion of reinforcement results in shear strength reduction. Corrosion has become one of the main deterioration factors in reinforced concrete beam. This paper proposes a shear strength model for beams with inclined bars based on a limit equilibrium method. The proposed model can be applied to both corroded and uncorroded reinforced concrete beams. Besides the tensile strength of longitudinal steel bars, the shear capacity provided by the concrete on the top of the diagonal crack, the tensile force of the shear steel at the diagonal crack, the degradation of the cross-sectional area and strength of the reinforcements induced by corrosion are all considered. An experimental work on two groups accelerated corroded beams was performed. Good agreements were found between the proposed theoretical predictions and experimental observations.Entities:
Keywords: corrosion; diagonal crack; inclined bar; reinforced concrete; shear strength
Year: 2019 PMID: 30934745 PMCID: PMC6480138 DOI: 10.3390/ma12071014
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Shear failure and diagonal crack reinforcement internal force: (a) shear compression failure; and (b) schematic diagram of steel bars at the diagonal crack.
Figure 2Triangle element isolation body force diagram.
Figure 3Forces on free-body diagram above critical diagonal crack.
Figure 4Calculating model diagram.
Figure 5Details of experimental design (unit: mm).
Details of various reinforcements.
| Grade | Steel Bar |
| Maximum Strength/MPa | |
|---|---|---|---|---|
| HRB335 | Longitudinal bar | 28 | 365.70 | 519.30 |
| HRB335 | Hanger bar | 12 | 369.30 | 513.60 |
| HRB335 | Inclined bar | 12 | 367.10 | 517.10 |
| HPB235 | Stirrup | 6 | 337.90 | 482.20 |
Summary of experimental results.
| Beams Numbers |
|
|
|
| |
|---|---|---|---|---|---|
| A-0 | 0.00 | 0.00 | 0.00 | 36.5 | −1121 |
| A-1 | 0.00 | 0.00 | 4.23 | 37.5 | −1116 |
| A-2 | 0.00 | 0.00 | 6.25 | 36.5 | −1034 |
| A-3 | 0.00 | 0.00 | 11.23 | 35.4 | −1102 |
| A-4 | 0.00 | 0.00 | 21.57 | 38.3 | −1248 |
| A-5 | 0.00 | 0.00 | 22.51 | 37.2 | −1138 |
| A-6 | 0.00 | 0.00 | 36.33 | 37.5 | −1165 |
| B-0 | 0.00 | 0.00 | 0.00 | 34.8 | −1050 |
| B-1 | 4.27 | 12.07 | 18.11 | 27.9 | −972 |
| B-2 | 6.32 | 14.54 | 29.17 | 28.7 | −1116 |
| B-3 | 6.73 | 14.62 | 31.14 | 32.6 | −970 |
| B-4 | 8.41 | 20.73 | 43.51 | 31.9 | −1027 |
| B-5 | 9.52 | 28.42 | 53.79 | 26.0 | −1141 |
| B-6 | 11.42 | 34.96 | 68.35 | 31.8 | −1139 |
, and are the corrosion levels of longitudinal steel bar, diagonal reinforcement and stirrups, respectively.
Figure 6Load–deflection curves at mid-span: (a) Group A; and (b) Group B.
Figure 7Failure modes for experimental members.
Figure 8Load–maximum diagonal crack width curves: (a) Group A; and (b) Group B.
Figure 9Load–strain curves in shear-bending section of concrete: (a) Group A; and (b) Group B.
Figure 10Comparison between calculated and experimental results.